▼
Scroll to page 2
of
4
DO NOT DRILL THE SIDES OF THE UNIT CONTROL. USE AVAILABLE KNOCK OUTS AT THE BOTTOM OF THE UNIT. 115/230 VAC VOLTAGE SELECTOR N L IN1 V1 230V ON 0-10V Aux + _ 1 2 3 { - POWER SUPPLY OUTPUT 230 VAC (115 VAC) { VARIABLE G MOTOR LOAD G L2 (N) L1 (HOT) L2 (N) OUTPUT MAX 10 AMP. L1 (HOT) { + 0-10V SIGNAL FROM MAIN CONTROLLER CONTROLLER POWER SUPPLY 230 VAC (115 VAC) PMV-010 USING A MOTOR LOAD NOTES 1 WARNING 2 3 When the controller is shipped, all DIP switches are set to the OFF position. ALWAYS close the controller before applying power to it. # OFF ON 1 0-10V 10-0V 2 MOTOR LIGHTS 3 INCANDESCENT FLUORESCENT 1. PROVIDE SURGE PROTECTION (TO INCLUDE PROTECTION FROM LIGHTTNING) FROM POWER SUPPLY TO CONTROL AND FROM CONTROL TO OUTPUT EXTENDED PROBE. CONSULT A CERTIFIED ELECTRICIAN FOR SPECIFIC A CERTIFIED RECOMMENDATIONS. 2. SAME PHASES MUST BE USED TO POWER VARIABLE FANS AND THE PMV-010 MODULE ON 3 PHASE POWER. REV 01 WIRING DIAGRAM EN PMV-010 REV 02 #891-00248 Please scan the QR Code to access the complete manual or visit the website. Cumberland: http://www.cumberlandpoultry.com AP: http://www.automatedproduction.com AP ON Cumberland DIP SWITCHES GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc Canada J3Z 1G5 • Phone: 1-877-926-2777 E-mail: [email protected] Page 1 2 WIRE FLUORESCENT OUTPUT L1 VARIABLE GND L2 (N) L1 FLUORESCENT OUTPUT MAX. OUTPUT 10 AMP. CONTROL POWER SUPPLY 230 VAC (115 VAC) G 1 { { + 0-10V Aux GND L2 (N) L1 2 WIRE FLUORESCENT POWER SUPPLY 230 VAC (115 VAC) VARIABLE GND L2 (N) L1 FLUORESCENT OUTPUT MAX. OUTPUT 10 AMP. 2 WIRE INCANDESCENT OUTPUT DIP SWITCHES + 0-10V Aux GND L2 (N) VARIABLE L1 GND L2 (N) L1 INCANDESCENT OUTPUT MAX. OUTPUT 10 AMP. { CONTROL POWER SUPPLY 230 VAC (115 VAC) { 2 WIRE INCANDESCENT POWER SUPPLY 230 VAC (115 VAC) 2 3 When the controller is shipped, all DIP switches are set to the OFF position. ALWAYS close the controller before applying power to it. 4 5 0-10V + - G 1 N L IN1 V1 PMV-010 WARNING { 3 WIRE FLUORESCENT POWER SUPPLY 230 VAC (115 VAC) NOTES ON 1 LIGHT PROGRAM CONTROLLER { CONTROL POWER SUPPLY 230 VAC (115 VAC) 0-10V - + 4 5 N L IN1 0-10V - + GND L2 (N) LIGHT PROGRAM CONTROLLER PMV-010 G 1 + 0-10V Aux V1 4 5 LIGHT PROGRAM CONTROLLER N L IN1 V1 PMV-010 3 WIRE FLUORESCENT OUTPUT # OFF ON 1 0-10V 10-0V 2 MOTOR LIGHTS 3 INCANDESCENT FLUORESCENT DO NOT DRILL THE SIDES OF THE UNIT CONTROL. USE AVAILABLE KNOCK OUTS AT THE BOTTOM OF THE UNIT. 1. PROVIDE SURGE PROTECTION (TO INCLUDE PROTECTION FROM LIGHTTNING) FROM POWER SUPPLY TO CONTROL AND FROM CONTROL TO OUTPUT EXTENDED PROBE. CONSULT A CERTIFIED ELECTRICIAN FOR SPECIFIC A CERTIFIED RECOMMENDATIONS. 2. SAME PHASES MUST BE USED TO POWER VARIABLE FANS AND THE PMV-010 MODULE ON 3 PHASE POWER. PMV-010 USING A MOTOR LOAD WIRING DIAGRAM EN PMV-010 #891-00248 REV 02 Page 2 NE PAS PERCER LE CÔTÊ DU CONTRÔLEUR. UTILISER LES ENTRÊES PRÊVUES À CET EFFET. 115/230 VAC SÉLECTEUR DE TENSION N L IN1 V1 230V ON 0-10V Aux + _ 1 2 3 - ALIMENTATION DE LA SORTIE 230 VAC (115 VAC) { VARIABLE G CHARGE MOTEUR G L2 (N) L1 (HOT) L2 (N) SORTIE MAX. 10 AMP. L1 (HOT) { + { SIGNAL 0-10V DU CONTRÔLEUR PRINCIPAL ALIMENTATION DU CONTRÔLEUR 230 VAC (115 VAC) PMV-010 UTILISANT UNE CHARGE MOTEUR 1 2 3 Lorsque le contrôleur vous parvient de l’usine, tous les commutateurs sont à la position OFF. TOUJOURS mettre le contrôleur hors tension avant d’ouvrir le couvercle. # DÉSACTIVÉ ACTIVÉ 1 0-10V 10-0V 2 MOTEUR LUMIÉRES 3 INCANDESCENT FLUORESCENT 1. DES PROTECTEURS DE SURTENSION SONT RECOMMANDÉS ENTRE L’ALIMENTATION, LE CONTRÔLEUR ET LES SONDES. CONSULTER UN ÉLECTRICIEN AU BESOIN. REV 01 SCHÉMA DE BRANCHEMENT PMV-010 REV 02 #891-00248 2. LORS D’UNE ALIMENTATION 3 PHASES, LES MÊMES PHASES DOIVENT ÊTRE UTILISÉES POUR ALIMENTER LES VENTILATEURS VARIABLES ET LE PMV-010. FR Veuillez scanner le code QR pour accéder aux manuels complets ou visiter le site Web. Cumberland: http://www.cumberlandpoultry.com AP: http://www.automatedproduction.com AP ATTENTION NOTES ON Cumberland COMMUTATEURS INTERNES GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc Canada J3Z 1G5 • Phone: 1-877-926-2777 E-mail: [email protected] Page 1 L1 VARIABLE GND L2 (N) L1 SORTIE FLUORESCENTE SORTIE MAX. 10 AMP. ALIMENTATION DU CONTRÔLEUR 230 VAC (115 VAC) G 1 { { + 0-10V Aux GND L2 (N) L1 ALIMENTATION SORTIE FLUO. 2 FILS 230 VAC (115 VAC) VARIABLE GND L2 (N) L1 SORTIE FLUORESCENTE SORIE MAX. 10 AMP. SORTIE INCANDESCENT À 2 FILS ATTENTION 0-10V + - G 1 + 0-10V Aux GND L2 (N) VARIABLE L1 GND L2 (N) L1 SORTIE INCANDESCENTE SORTIE MAX. 10 AMP. { ALIMENTATION DU CONTRÔLEUR 230 VAC (115 VAC) { ALIMENTATION SORTIE INCANDESCENTE 230 VAC (115 VAC) { ALIMENTATION SORTIE FLUO. 3 FILS 230 VAC (115 VAC) NOTES ON 1 2 3 Lorsque le contrôleur vous parvient de l’usine, tous les commutateurs sont à la position OFF. TOUJOURS mettre le contrôleur hors tension avant d’ouvrir le couvercle. 4 5 CONTRÔLEUR DE PROGRAMMES LUMINEUX N L IN1 V1 PMV-010 COMMUTATEURS INTERNES { ALIMENTATION DU CONTRÔLEUR 230 VAC (115 VAC) 0-10V - + 4 5 N L 0-10V - + GND L2 (N) CONTRÔLEUR DE PROGRAMMES LUMINEUX PMV-010 G 1 + 0-10V Aux IN1 4 5 CONTRÔLEUR DE PROGRAMMES LUMINEUX N L IN1 V1 PMV-010 SORTIE FLUORESCENTE À 3 FILS V1 SORTIE FLUORESCENTE À 2 FILS # DÉSACTIVÉ ACTIVÉ 1 0-10V 10-0V 2 MOTEUR LUMIÉRES 3 INCANDESCENT FLUORESCENT NE PAS PERCER LE CÔTÊ DU CONTRÔLEUR UTILISER LES ENTRÊES PRÊVUES À CET EFFET. 1. DES PROTECTEURS DE SURTENSION SONT RECOMMANDÉS ENTRE L’ALIMENTATION, LE CONTRÔLEUR ET LES SONDES. CONSULTER UN ÉLECTRICIEN AU BESOIN. 2. LORS D’UNE ALIMENTATION 3 PHASES, LES MÊMES PHASES DOIVENT ÊTRE UTILISÉES POUR ALIMENTER LES VENTILATEURS VARIABLES ET LE PMV-010. PMV-010 UTILISANT UNE CHARGE MOTEUR SCHÉMA DE BRANCHEMENT FR PMV-010 #891-00248 REV 02 Page 2