▼
Scroll to page 2
NOTES S1 2 IN 1 OUT L1 L2 / N 230V ( ( 115/230 VAC SELECTION SWITCH GREEN NO SHIELD 3. SAME PHASES MUST BE USED TO POWER VARIABLE FANS AND CONTROLS ON 3 PHASES POWER. WHITE - ORANGE 2. PROVIDE SURGE PROTECTION (TO INCLUDE PROTECTION FROM LIGHTTNING) FROM POWER SUPPLY TO CONTROL AND FROM CONTROL TO OUTPUT EXTENDED PROBE. CONSULT A CERTIFIED ELECTRICIAN FOR SPECIFIC RECOMMENDATIONS. G 1 1. INSTALLATION OF A GOOD QUALITY ALARM SYSTEM IS STRONGLY ADVISED TO WARN OF POWER FAILURES AND HIGH/LOW TEMPERATURES. CONTROL SUPPLY 3 4 DO NOT DRILL THIS SIDE OF THE UNIT CONTROL. USE AVAILABLE KNOCK OUTS AT THE BOTTOM OF THE UNIT. ELECTRICAL DISTRIBUTION PANEL G L1 4. WE RECOMMAND SEPARATE CIRCUIT BREAKERS FOR EACH OUTPUT STAGE. L2 (N) SAME PHASES MUST BE USED TO POWER PMV, CVS & FANS. G L1 L2 (N) C/D SERIES CONTROLLER Fan Stage 1 10A Mot., 115 VAC (1/2 HP) 230 VAC (1.5 HP) { { CONTROL POWER SUPPLY 230 VAC (115 VAC) STAGE 1 POWER SUPPLY 230 VAC (115 VAC) DISCONNECT VARIABLE 1 G EXAMPLE OF SPLIT CONNNECTION GREEN + SHIELD WHITE - ORANGE C/D SERIES CONTROLLER PMV-1 #1 PMV-1 #2 Please scan the QR Code to access the complete manual or visit the website. Cumberland: http://www.cumberlandpoultry.com AP: http://www.automatedproduction.com EN PMV-1 AP Cumberland REV 03 WIRING DIAGRAM #891-00249 REV 08 GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc • Canada J3Z 1G5 • Phone: 1-877-926-2777 E-mail: [email protected] Page 1 ALIMENTATION DU CONTRÔLEUR NOTES ENTRÉE SORTIE L1 L2 / N 230V 2 ( 1 NE PAS PERCER LE CÔTÊ DU CONTRÔLEUR. UTILISER LES ENTRÊES PRÊVUES À CET EFFET. S1 ( 4. IL EST RECOMMANDÉ DE RACCORDER CHAQUE SORTIE DE STAGE À UN DISJONCTEUR SÉPARÉ. 115/230 VAC SÉLECTEUR DE VOLTAGE VERT PA S DE SHIELD 3. LORS D’UNE ALIMENTATION 3 PHASES, LES MÊMES PHASES DOIVENT ÊTRE UTILISÉES POUR ALIMENTER LES VENTILATEURS VARIABLES ET LE CONTRÔLEUR. BLANC - ORANGE 2. DES PROTECTEURS DE SURTENSION SONT RECOMMANDÉS ENTRE L’ALIMENTATION, LE CONTRÔLEUR ET LES SONDES. CONSULTER UN ÉLECTRICIEN AU BESOIN. G 1 1. L’INSTALLATION D’UN SYSTÈME D’ALARME EST FORTEMENT RECOMMANDÉE AFIN DE DÉTECTER LES PERTES DE COURANT ET LES HAUTES/BASSES TEMPÉRATURES. 3 4 PANNEAU DE DISTRIBUTION ÉLECTRIQUE G LES MÊMES PHASES DOIVENT ÊTRE UTILISÉES POUR ALIMENTER LES MODÈLES SUIVANTS : PMV, CVS, & VENTILATEURS. L1 L2 (N) G L1 L2 (N) CONTRÔLEUR SÉRIE C/D Stage de Ventilation 1 10A Mot., 115 VAC (1/2 HP), 230 VAC (1.5 HP) { { ALIMENTATION DU CONTRÔLEUR 230 VAC (115 VAC) ALIMENTATION STAGE 1 230 VAC (115 VAC) INTERRUPTEUR VARIABLE 1 G EXEMPLE D’UNE CONNECTION MULTIPLE VERT + SHIELD BLANC - ORANGE CONTRÔLEUR SÉRIE C/D PMV-1 #1 PMV-1 #2 Veuillez scanner le code QR pour accéder aux manuels complets ou visiter le site Web. Cumberland: http://www.cumberlandpoultry.com AP: http://www.automatedproduction.com FR PMV-1 AP Cumberland REV 03 SCHÉMA DE BRANCHEMENT #891-00249 REV 08 GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc • Canada J3Z 1G5 • Phone: 1-877-926-2777 E-mail: [email protected] Page 1