STAGE 1 POWER SUPPLY 230 VAC (115 VAC) { { G G 1 SAME PHASES MUST BE USED TO POWER MPV, TC4/TC5 & FANS. L1 (HOT) L2 (N) 2. SAME PHASES MUST BE USED TO POWER VARIABLE FANS, MPV AND CONTROLLER ON 3 PHASES POWER. GREEN NO SHIELD WHITE - ORANGE ELECTRICAL DISTRIBUTION PANEL CONTROL POWER SUPPLY 230 VAC (115 VAC) 1. PROVIDE SURGE PROTECTION (TO PROTECT AGAINST LIGHTNING) FROM POWER SUPPLY TO CONTROLLER AND FROM CONTROLLER TO MPV. CONSULT A CERTIFIED ELECTRICIAN FOR SPECIFIC RECOMMENDATIONS. SELECTION SWITCH 115/230 VAC L1 \ H L2 \ N NOT USED STAGE 1 / OUTPUT COMMON / INPUT 230V DO NOT DRILL THIS SIDE OF THE UNIT CONTROL. USE AVAILABLE KNOCK OUTS AT THE BOTTOM OF THE UNIT. NOTES 3. SAME PHASES MUST BE USED TO POWER VARIABLE FANS AND CONTROLS ON 3 PHASES POWER. TC4/TC5 CONTROLLER G L1 (HOT) Fan Stage1 10A Mot.,115 VAC (1/2 HP), 230 VAC (1.5 HP) L2 (N) G 1 BREAKER BOX TO MPV MODULE VARIABLE WHITE - ORANGE GREEN + SHIELD Combine one of those: 115 VAC 230 VAC N/L2 OUT IN VARIABLE STAGE L1 EXAMPLE OF SPLIT CONNNECTION AB Connected with AB BC Connected with BC AC Connected with AC POWER REV 03 WIRING DIAGRAM EN MPV Please scan the QR Code to access the complete manual or visit the website. Cumberland: http://www.cumberlandpoultry.com AP: http://www.automatedproduction.com N MPV #1 MPV #2 L1 B VARIABLE REV 13 C AP TC4/TC5 CONTROLLER A Cumberland N/L2 #891-00197 GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc Canada J3Z 1G5 • Phone: 1-877-926-2777 E-mail: [email protected] Page 1 ALIMENTATION STAGE 1 230 VAC (115 VAC) 1 UTILISER LES MÊME PHASES POUR ALIMENTER LE MPV, LE TC4/TC5 ET LES VENTILATEURS. L2 (N) 2. LORS D’UNE ALIMENTATION 3 PHASES, G VERT SANS BLINDAGE { { G L1 (HOT) BLANC - ORANGE PANNEAU DE DISTRIBUTION ÉLECTRIQUE ALIMENTATION DU CONTRÔLEUR 230 VAC (115 VAC) SONT RECOMMANDÉS ENTRE L’ALIMENTATION, LE CONTRÔLEUR ET LE MPV. CONSULTER UN ÉLECTRICIEN AU BESOIN. 115/230 VAC SÉLECTEUR DE VOLTAGE L1 \ H L2 \ N VIDE STAGE 1 / OUTPUT COMMON / INTPUT 1. DES PROTECTEURS DE SURTENSION 230V NE PAS PERCER LE CÔTÉ DU CONTRÔLEUR. UTILISER LES ENTRÉES PRÉVUES À CET EFFET. NOTES LES MÊMES PHASES DOIVENT ÊTRE UTILISÉES POUR ALIMENTER LES VENTILATEURS VARIABLES. LE CONTRÔLEUR ET LE MPV. 3. LORS D’UNE ALIMENTATION 3 PHASES, LES MÊMES PHASES DOIVENT ÊTRE UTILISÉES POUR ALIMENTER LES VENTILATEURS VARIABLES ET LE CONTRÔLEUR . CONTRÔLEUR TC4/TC5 G L1 (HOT) Stage de Ventilation 1 10A Mot., 115 VAC (1/2 HP), 230 VAC (1.5 HP) L2 (N) G 1 CIRCUIT DE PROTECTION AU MODULE MPV VARIABLE BLANC - ORANGE OUT L1 STAGE VARIABLE 115 VAC 230 VAC POWER Utiliser une des Combinaisons Suivantes: N/L2 A MPV #2 FR MPV REV 13 #891-00197 Veuillez scanner le code QR pour accéder aux manuels complets ou visiter le site Web. Cumberland: http://www.cumberlandpoultry.com AP: http://www.automatedproduction.com N MPV #1 SCHÉMA DE BRANCHEMENT L1 B VARIABLE C WIRING DIAGRAM AP CONTRÔLEUR TC4/TC5 REV 03 AB Connecté avec AB BC Connecté avec BC AC Connecté avec AC Cumberland IN EXEMPLE D’UNE CONNEXION MULTIPLE N/L2 VERT + BLINDAGE EN GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc EXPERT VT110 Canada J3Z 1G5 • Phone: 1-877-926-2777 REV 12 #891-00074 E-mail: [email protected] Page 1