S Z

Patricia S.

How is the G2001S safety control box wired?

Power is connected to terminals 3 (24V DC), 13 (GND), and 15 (Reset). Safety inputs use terminals 17/18 (OSSD) and 1/2 (Muting sensors). Relay outputs are located on terminals 23/24 (R1) and 12/22 (R2). Configuration is handled via terminals 14 (Restart) and 6 (Manual/Auto mode). Output contacts must be protected by a 3.6 A fuse.

S Z

Patricia S.

What are the primary wiring connections for the G2001S safety control box?

Connect power to terminals 3, 13, and 15. Safety and muting inputs use terminals 17, 18, 1, and 2. Relay outputs are connected to terminals 23, 24, 12, and 22.

S Z

Patricia S.

What is the wiring configuration for the G2001S safety control unit?

Power is connected to terminals 3 (L+), 13 (L-), and 15 (L+). Safety OSSD inputs use terminals 17 and 18. Muting sensors connect to terminals 1 and 2, with the muting lamp on terminal 10. Relay outputs R1 and R2 are located on terminals 23/24 and 12/22.