Installation manual | CARLO GAVAZZI EM10DINAV81XO1PF Guide d'installation

Add to My manuals
2 Pages
Installation manual | CARLO GAVAZZI EM10DINAV81XO1PF Guide d'installation | Fixfr
CARLO GAVAZZI
EM10 DIN Energy Meter
Automation Components
[1]
Carlo Gavazzi Controls SpA,
Via Safforze, 8 - 32100
Belluno (Italy)
Tel. +39 0437 931000,
Fax +39 0437 931021
EM10DIN IM ML CODE 8021672 010711
VDC
[2]
2.5mm2 - 10mm2
0.5 Nm
0.5 Nm
EM10-DIN
18mm
1.1 Nm
44mm
0.5 Nm
1.1 Nm
0.5 Nm
45.5mm
1.5mm2
90mm
Cable cross-section area, Area del
cavo, Kabelquerschnitt, Section de
câbles, Sección de cable
45mm
Screws tightening torque, Coppia di serraggio viti, Kabelquerschnitt, Section de câbles,
Sección de cable.
VDC
[3]
67.5mm
17.5 +0.5/-0mm
ENGLISH
ITALIANO
DEUTSCH
FRANÇAIS
ESPAÑOL
WIRING DIAGRAMS
[1]1-phase connection. NOTE: The 3 and 4 terminals, in
the instrument, are wired together.
[2]One open collector output, VDC Reference.
[3]One open collector output, GND Reference.
The load resistances (RC) must be designed so that the close
contact current is lower than 100mA; the VDC voltage must be
lower than or equal to 30VDC.
COLLEGAMENTI ELETTRICI
[1]Connessione monofase. NOTA: I morsetti 3 e 4 sono
collegati tra loro internamente.
[2]Singola uscita a collettore aperto, riferimento VDC.
[3]Singola uscita a collettore aperto, riferimento GND.
La resistenza di carico (Rc) dev’essere calcolata in modo che la
corrente a contatto chiuso sia inferiore a 100 mA; la tensione VCC
dev’essere inferiore o uguale a 30V.
Schémas de câblage
[1]Connexion 1 phase. NOTES: les bornes 3 et 4 sont
connectés ensemble dans l’appareil.
[2]1 sortie collecteur ouvert, référence VDC.
[3]1 sortie collecteur ouvert, référence GND.
Les résistances de charge (RC) doivent être choisies de façon
à ce que le courant de contact fermé soit inférieur à 100mA; la
tension VCC doit être inférieure ou équivalente à 30VCC.
DIAGRAMAS DE CONEXIONES
[1]Conexión Monofásica. NOTA: los terminales 3 y 4 están
cableados internamente en el equipo.
[2]1 salida de colector abierto, referencia VCC.
[3]1 salida de colector abierto, referencia común.
La resistencia de carga (Rc) debe estar calculada de manera que
la intensidad a contacto cerrado sea inferior a 100mA; la tensión
VCC debe ser inferior o igual a 30VCC.
SAFETY PRECAUTIONS
Read carefully the instruction manual. If the instrument is used in a manner not specified by the producer, the protection provided by the instrument may be impaired.
Maintenance: make sure that the connections are correctly
carried out in order to avoid any malfunctioning or damage to the
instrument. To keep the instrument clean, use a slightly damp
cloth; do not use any abrasives or solvents. We recommend to
disconnect the instrument before cleaning it.
NORME DI SICUREZZA
Leggere attentamente il manuale istruzioni.
Qualora l’apparecchio venisse adoperato in un modo
non specificato dal costruttore, la protezione prevista dall’apparecchio potrebbe essere compromessa. Manutenzione: assicurarsi che i collegamenti siano effettuati correttamente al fine
di evitare qualsiasi malfunzionamento o danneggiamento dello
strumento. Per mantenere pulito lo strumento usare un panno
leggermente inumidito; non usare abrasivi o solventi. Si consiglia
di scollegare lo strumento prima di pulirlo.
SCHALTBILDER
[1]1-ph Anschluss. Hinweis: Klemme 3 und 4, sind im
Gerät verbunden.
[2]1 open Kollektor Ausgang, VDC Bezug.
[3]1 open Kollektor Ausgang, GND Bezug.
Die Widerstandslast (Rc) muss so bemessen werden, dass
der Schaltstrom bei geschlossenem Kontakt kleiner als 100mA
ist, die Versorgungsspannung “VDC” muss kleiner oder gleich
30VDC sein.
SICHERHEITSBESTIMMUNGEN
Die Betriebsanleitung aufmerksam lesen. Sollte
das Gerät nicht gemäss der Herstellerangaben verwendet werden, könnte der vom Gerät vorgesehene Schutz
beeinträchtigt werden. Wartung: Beachten Sie den korrekten
Anschluss aller Anschlussterminals um eine Beschädigung des
Instruments zu vermeiden. Das Gerät mit einem feuchten Tuch
reinigen; keine Scheuer- oder Lösemittel verwenden. Das Gerät
vor der Reinigung ausschalten.
MESURES DE SECURITE
Lire attentivement le manuel de l’utilisateur. Si
l’appareil est utilisé dans des conditions différentes
de celles spécifiées par le fabricant, le niveau de protection prévu
par l’instrument peut être compromis. Entretien: s’assurer que
les connexions sont réalisées correctement dans le but d’éviter
toutes fautes ou endommagements de l’appareil. Pour nettoyer
l’instrument, utiliser un chiffon humide; ne pas utiliser d’abrasifs
ou de solvants. Il faut déconnecter le dispositif avant de procéder
au nettoyage.
TECHNICAL SPECIFICATIONS
Rated inputs: system: 1, current range (by shunt)
AV7
and AV8: 5(32)A. Voltage range, AV7: 120 VLN AC, AV8: 230
VLN AC. Accuracy (Display), (@25°C ±5°C, R.H. ≤60%, 48 to
62Hz), AV8 model Iref: 5A, Imax: 32A; Un: 230VLN (-20%
+20%). Active energy: class B according to EN50470-3, Class
B according to EN50470-3, reference values Iref: 5A, Imax: 32A,
0.1 Iref: 0.5A. Start up current: 20mA. Energy additional errors:
influence quantities according to EN50470-3. Temperature drift
≤200ppm/°C. Sampling rate: 4096 samples/s @ 50Hz 4096
samples/s @ 60Hz. Display: 1 line (max: 6 DGT). Type: LCD, h
7mm. Energie indication: total: 6 DGT. LEDs: red LED (Energy
consumption), 1000 pulses/kWh (Max Frequency 16 Hz) according to EN50470-1. Measurements: kWh from 0,01 to 999999
(autoranging). Method TRMS measurements of distorted wave
forms. Coupling type: direct. Crest factor: Iref 5A ≤4 (45A max.
peak). Current overload: continuous 32A, @ 50Hz. For 10ms
960A, @ 50Hz. Voltage overload: continuous 1.2 Un. For 500ms
2 Un. Input impedance: 230VL-N (AV8) >720KΩ; 5(32) A (AV8)
<0.5VA. Frequency: 48 to 62 Hz.
Digital output (on request): number of outputs 1. Type: open
collector, 1000 pulses/kWh. Signal: VON 1.2 VDC/ max. 100 mA
VOFF 30 VDC max. Pulse duration: ≥100ms < 120msec (ON),
CARATTERISTICHE TECNICHE
Ingressi di misura: sistema: 1. Corrente (shunt) AV7 e AV8: 5(32)
A. Tensione AV7: 120VLN CA; AV8: 230VLN CA. Precisione
(Display) (@25°C ±5°C, U.R. ≤60%, 48-62Hz), modello AV8:
Iref: 5A, Imax: 32A; Un: 230VLN -20% +20%. Energia: Classe B
secondo EN50470-3. Iref: 5A, Imax: 32A; 0,1 Iref: 0,5A. Corrente
di avviamento: 20mA. Errori addizionali. Grandezze di influenza
secondo EN50470-3. Deriva termica: ≤200ppm/°C. Frequenza
di campionamento. 4096 campioni/s a 50Hz, 4096 campioni/s
a 60Hz. Display: 1 linea (max 6 DGT). Tipo LCD, h 7mm,
Indicazione energia, totale: 6 DGT. LED rosso (energia consumata), 1000 impulsi/kWh (massima frequenza 16Hz) secondo
EN50470-1. Misure: kWh da 0,01 a 999999 (autorange); misura
delle forme d’onda distorte con metodo TRMS . Tipo di accoppiamento: diretto. Fattore di cresta: Iref 5A ≤4 (45A max. picco).
Sovraccarico corrente: continuo 32A, a 50Hz, per 10ms: 960A,
a 50Hz. Sovraccarico tensione: continuo: 1,2 Un, per 500ms 2
Un. Impedenza d’ingresso: 230VL-N (AV8); >720KΩ; 5(32)A
(AV8) < 0,5VA. Frequenza: da 48 a 62 Hz.
Uscita ad impulsi (a richiesta): numero uscite 1. Tipo a collettore
aperto, 1000 impulsi/kWh. Segnale VON: 1,2VCC max 100mA.
VOFF: 30VCC max. Durata dell’impulso ≥100ms <120msec (ON),
≥120ms (OFF), secondo EN62052-31. Isolamento mediante
TECHNISCHE DATEN
Messeingänge: 1 Phasensystem. Strommessung: AV7 und
AV8: 5(32)A. Spannung AV7: 120VLN AC; AV8: 230VLN AC.
Genauigkeit (Anzeige) (@25°C ±5°C, r.F. ≤60%, 48-62Hz),
Modell AV8: Iref: 5A, Imax: 32A; Un: 230VLN -20% +20%.
Wirkleistung Klasse B gemäß EN50470-3. Iref: 5A, Imax: 32A;
0,1 Iref: 0,5A. Startstrom 20mA. Zusätzlicher Energiefehler.
Bereichsüberschreitung gemäß EN50470-3. Temperaturdrift:
≤200ppm/°C. Abtastrate. 4096 Abtastwerte/s bei 50Hz, 4096
Abtastwerte/s bei 60Hz. Anzeige: 1 Zeile (max 6 stellig). Typ
LCD, h 7mm, Energien, Gesamt Tarif: 6 stellig. LEDs: rote LED
(Energie Verbrauch), 1000 Imp/kWh (max. Frequenz 16Hz)
gemäß EN50470-1. Messung: kWh von 0.01 bis 999999 (mit
automatischer Messbereichsumschaltung); TRMS-Messungen
von verzerrten Wellenformen. Anschlußtyp: Direkt.
Scheitelwertfaktor: Iref 5A ≤4 (45A max. Spitzenwert).
Überlaststrom: Dauer 32A, @ 50Hz, für 10ms: 960A, @
50Hz. Überlastspannung: dauer: 1,2 Un, für 500ms 2 Un.
Eingangsimpedanz: 230VL-N (AV8); >720KΩ; 5(32)A (AV8) <
0,5VA. Frequenz: 48 bis 62 Hz.
Digitalausgänge (auf Anfrage): Anzahl der Ausgänge 1. Typ:
open Kollektor, 1000 Impuls/kWh. Signal: VON: 1,2VDC max
100mA. VOFF: 30 VDC max. Impulsdauer ≥100ms <120msec
CARACTÉRISTIQUES TECHNIQUES
Entrées nominales: système monophasé. Plage de courant (par
shunt): AV7 et AV8: 5(32)A. Plage de tension: AV7: 120VLN
CA; AV8: 230VLN CA. Précision: (afficheur) (@25°C ±5°C,
H.R. ≤60%, 48-62Hz), modèle AV8: Iref: 5A, Imax: 32A; Un:
230VLN -20% +20%. Energie: Classe B selon EN62053-21,
classe B selon EN50470-3. Iref: 5A, Imax: 32A; 0,1 Iref: 0,5A.
Courant de démarrage: 20mA. Erreurs additionnelles énergie:
quantités influentes selon EN50470-3. Dérive de température:
≤200ppm/°C. Taux d’échantillonnage. 4096 échantillons/s @
50Hz, 4096 échantillons/s @ 60Hz. Afficheur: 1 ligne (max 6
DGT). Type LCD, h 7mm, Energie, totale: 6 DGT. LED rouge
(consommation d’énergie), 1000 imp./kWh (fréquence max.
16Hz) selon EN50470-1. Mesures: kWh de 0,01 a 999999 (auto
étallonage de la gamme); mesures TRMS de formes d’ondes
déformées . Type de raccordement: direct. Facteur de crête:
Iref 5A ≤4 (45A pic. max). Surcharges de courant: continu 32A,
a 50Hz, pour 10ms: 960A, à 50Hz. Surcharges de tension:
continu: 1,2 Un, pour 500ms 2Un. Impédance d’entrée: 230VLN (AV8); >720KΩ; 5(32)A (AV7-AV8) < 0,5VA. Fréquence: 48
à 62 Hz.
Sortie logique (sur demande): nombre de sorties 1. Type:
collecteur ouvert, 1000 impulsions/kWh. Signal VON: 1,2VCC
NORMAS DE SEGURIDAD
Lea atentamente este manual de instrucciones.
Si el instrumento se usa de modo distinto al indicado
por el fabricante, la protección de seguiridad ofrecida por el
instrumento podrá resultar dañada. Mantenimiento: asegúrese
de montar correctamente los módulos extraibles y los cables
correspondientes para evitar un mal funcionamiento y posibles
daños en el equipo. Para limpiar el equipo, utilizar siempre un
trapo ligeramente humedecido, nunca productos abrasivos o
disolventes. Se recomienda desconectar siempre el instrumento
antes de limpiarlo.
!
!
!
!
!
ESPECIFICACIONES TÉCNICAS
Entradas de medida: sistema monofásico: 1. Escala de intensidad (mediante shunt interno) AV7 y AV8: 5(32)A. Escala de
tensión AV7: 120VLN CA; AV8: 230VLN CA. Precisión (@25°C
±5°C, H.R. ≤60%, 48-62Hz), modelo AV8: Iref: 5A, Imax: 32A;
Vn: 230VLN -20% +20%. Energía: Clase B según EN50470-3.
Iref: 5A, Imax: 32A; 0,1 Iref: 0,5A. Intensidad de arranque: 20mA.
Errores adicionales de energía: según norma EN50470-3.
Deriva térmica: ≤200ppm/°C. Frecuencia de muestreo: 4096
lecturas/s a 50Hz, 4096 lecturas/s a 60Hz. Display: 1 línea (máx
6 díg). Tipo LCD, altura 7mm, Energías: total: 6 DGT. LED rojo
(consumo de energía), 1000 imp./kWh (frecuencia máx. 16Hz)
según EN50470-1. Medidas: kWh de 0,01 a 999999 (autorrango); Medida TRMS de tensión de una onda distorsionada. Tipo de
conexión: directa. Factor de cresta: Iref 5A ≤4 (45A pico máx.).
Protec. contra sobrecargas intensidad: continua 32A, a 50Hz,
durante 10ms: 960A, a 50Hz. Protec. contra sobrecargas de
tensión: continua: 1,2 Vn, durante 500ms 2 Vn. Impedancia
de entrada: 230VL-N (AV8); >720KΩ; 5(32)A (AV7-AV8) <
0,5VA. Frecuencia: de 48 a 62 Hz. Salidas digitales (opcional):
número de salidas 1. Tipo a colector abierto, 1000 pulsos/kWh.
Señal VON: 1,2 VCC máx 100mA. VOFF: 30VCC máx. Duración
≥120ms (OFF), according to EN62052-31. Insulation: by means
of optocouplers, 4000 VRMS output to measuring inputs.
Operating temperature: -25°C to +55°C (13°F to 131°F) (R.H.
from 0 to 90% non-condensing @ 40°C) according to EN504703. Storage temperature: -30°C to +70°C (22°F to 140°F)
(R.H. < 90% non-condensing @ 40°C) according to EN50470-3.
Installation category: cat. III (IEC60664, EN60664). Insulation
(for 1 minute) 4000 VRMS between measuring inputs and
digital output (O1). Dielectric strength: 4000 VRMS for 1 minute
CMRR. Noise rejection: 100 dB, 48 to 62 Hz. EMC: according to EN50470-1. Electrostatic discharges: 8kV air discharge;
immunity to irradiated electromagnetic fields: test with applied
current: 10V/m from 80 to 2000MHz; test without any applied
current: 30V/m from 80 to 2000MHz; burst: on current and
voltage measuring input circuits: 4kV. Immunity to conducted
disturbances 10V/m from 150KHz to 80MHz. Surge: on current
and voltage measuring input circuits: 4kV. Radio frequency
suppression according to CISPR 22. Standard compliance:
safety IEC60664, IEC61010-1 EN60664, EN61010-1 EN504701. Metrology: EN50470-3, EN50470-3. Pulse output DIN43864,
IEC62053-31. Approvals: CE, PTB (Revenue Approvals).
Connections: screw-type. Cable cross-section area Min. 2.5
mm2, Max. 10 mm2 (measuring inputs). Screws tightening torque:
0.5 Nm / 1.1 Nm; Other terminals: 1.5 mm2, Screws tightening
torque: max 0.5 Nm. DIN Housing: dimensions (WxHxD) 17.5
x 90 x 67.5 mm. Material nylon PA66, self-extinguishing: UL 94
V-0. Mounting DIN-rail. *Protection degree: front IP40. Screw
terminals: IP20. Weight: approx. 100 g (packing included). Self
supplied version: 230 VLN (-20% +20%) 48-62Hz. Power
consumption: ≤ 3VA.
MID compliance
Accuracy: 0.9 Un ≤ U ≤ 1.1 Un; 0.98 fn ≤ f ≤ 1.02 fn; fn: 50Hz;
cosj: 0.5 inductive to 0.8 capacitive. Class B: I st: 0.02A; I min:
0.25A; I tr: 0.5A; I max: 32A. Operating temperature: -25°C to
+55°C (13°F to 131°F) (R.H. from 0 to 90% non-condensing @
40°C). EMC compliance: E2. *Protection degree: in order to
achieve the protection against dust and water required by the
norms harmonized to MID, the meter must be used only installed
in IP51 (or better) cabinets.
optoisolatori 4000VRMS tra uscita e ingressi di misura.
Temperatura di funzionamento: da -25°C a +55°C (da 13°F
a 131°F) (U.R. da 0 a 90% senza condensa @ 40°C) secondo
EN50470-3 . Temperatura di immagazzinamento: da -30°C
a +70°C (da 22°F a 140°F) (U.R. < 90% senza condensa
@ 40°C) secondo EN50470-3 . Categoria di installazione:
Cat. III (IEC60664, EN60664). Isolamento (per 1 minuto)
4000VRMS tra ingressi di misura ed uscita (O1). 4000VRMS tra
alimentazione e uscita digitale. Rigidità dielettrica 4000VRMS
per 1 minuto. Reiezione CMRR 100 dB, da 48 a 62 Hz EMC
secondo EN50470-1. Scariche elettrostatiche: 8kV scarica in
aria; Immunità campi elettromagnetici irradianti. Provato con corrente applicata: 10V/m da 80 a 2000MHz; Provato senza corrente
applicata: 30V/m da 80 a 2000MHz; Immunità ai transitori veloci
sui circuiti degli ingressi di misura in corrente e tensione: 4kV.
Immunità ai radiodisturbi condotti 10V/m da 150KHz a 80MHz.
Immunità ad impulso sui circuiti degli ingressi di misura in corrente
e tensione: 4kV. Emissioni in radiofrequenza secondo CISPR
22. Conformità alle norme: sicurezza IEC60664, IEC610101 EN60664, EN61010-1 EN50470-1. Metrologia EN50470-3,
EN50470-3. Uscita impulsiva DIN43864, IEC62053-31
Approvazioni: CE. Connessioni: a vite. Sezione del cavo: Min.
2,5 mm2, Max. 10 mm2 (ingressi di misura), coppia serraggio viti:
0,5 Nm/1,1 Nm.; altri morsetti: 1,5 mm2, coppia serraggio viti: max
0,5. Custodia DIN: dimensioni: 17,5 x 90 x 67 mm. Materiale:
Nylon PA66, autoestinguenza: UL 94 V-0. Montaggio: a guida
DIN. *Grado di protezione: frontale IP40. Connessioni: IP20.
Peso: circa 100 g (imballo incluso). Autoalimentazione: 230
VLN (-20% +20%) 48-62Hz. Autoconsumo: ≤ 3VA.
Conformità MID
Precisione 0,9 Un ≤ U ≤ 1,1 Un; 0,98 fn ≤ f ≤ 1,02 fn; fn: 50Hz;
cosj: da 0,5 induttivo a 0,8 capacitivo. Classe B; I st: 0,02A; I min:
0,25A; I tr: 0,5A; I max: 32A. Temperatura di funzionamento
da -25°C a +55°C (da 13°F a 131°F) (U.R. da 0 a 90% senza
condensa a 40°C). Conformità EMC: E2. *Grado di protezione:
al fine di conseguire la protezione contro polvere e acqua richieste dalle norme MID, il contatore deve essere utilizzato solo se
installato in armadietti IP51 (o superiore).
MID COMPLIANCE
CONFORMITÀ MID
For legal metrology all EM10 models have to be further
certified according to Annex II modules “D” or “F” of MID
directive. PAY ATTENTION: for legal purpose, the proper
metrology mark followed by the ID number referred to
the Annex II module “D” notified body or Annex II
module “F” verification laboratory shall be printed/
sticked on the meter.
Per la misura fiscale, tutti i modelli EM10 devono essere
ulteriormente certificati secondo l’Allegato II moduli “D”
o “F” della direttiva MID. ATTENZIONE: per la misura
fiscale, la marcatura metrologica seguita dal numero
identificativo dell’ente notificato Allegato II modulo “D”
o del laboratorio Allegato II modulo “F” deve essere
presente sullo strumento.
!
ATTENTION: To ensure correct function of
the instrument it is necessary to adhere to the
indicated screw tightening torque.
!
ATTENZIONE: a garanzia del buon funzionamento dello strumento si necessita il rispetto
della coppia di serraggio viti indicata.
(ON), ≥120ms (OFF), gemäß EN62052-31. Isolation durch
Optokoppler 4000VRMS Ausgang zu Messeingänge.
Betriebstemperatur: -25°C bis +55°C (13°F a 131°F) (r.F. von
0 bis 90% nicht kondensierend bei 40°C) gemäß EN50470-3 .
Lagertemperatur: -30°C bis +70°C (22°F bis 140°F) (r.F. von
0 bis 90% nicht kondensierend bei 40°C) gemäß EN504703 . Installationskategorie: Kat. III (IEC60664, EN60664).
Isolationsspannung (für 1 Minute) 4000 VRMS zwischen
Messeingang und Digitalausgang (O1). 4000VRMS zwischen
Stromversorgung und Digitalausgang. Durchschlagfestigkeit:
4000 VRMS für 1 Minute. Rauschdrückungsverhältnis:
CMRR 100 dB, von 48 bis 62Hz. EMC gemäß EN504701. Elektrostatische Entladungen: 8kV Luftentladungen;
Strahlungsimmunität Elektromagnetfeld. Test bei angelegtem
Strom: 10V/m bei 80 bis 2000MHz; Test ohne angelegten Strom:
30V/m von 80 bis 2000MHz; Überspannungsfestigkeit Stromund Eingangsspannungsmesskreis: 4kV. L e i t e r s t ö r u n g s immunität: 10V/m von 150KHz bis 80MHz. Surge: Strom- und
Eingangsspannungsmesskreis: 4kV. Störausstrahlung gemäß
CISPR 22. Standardkonformität: Sicherheit IEC60664,
IEC61010-1 EN60664, EN61010-1, EN50470-1. Metrologie
EN50470-3, EN50470-3. Impulsausgang DIN43864, IEC6205331 Zulassungen: CE. Anschlüsse: Schraubklemmen.
Kabelquerschnitt: Min. 2.5mm2, Max. 10mm2 (Messeingänge),
Anzugsmoment: 0.5Nm/1.1Nm; weitere Eingänge: 1.5mm2,
Anzugsmoment: max 0.5Nm. Gehäuse DIN: Abmessungen:
17.5 x 90 x 67 mm. Material: Nylon PA66, selbstlöschend: UL
94 V-0. Montage: DIN-Schiene. *Schutzgrad: Vorderseite IP40.
Schraubenklemmen: IP20. Gewicht: ca. 100g (inkl. Verpackung).
Modelle mit Eigenversorgung: 230VCA VLN (-20% +20%)
48-62Hz. Leistungsaufnahme: ≤ 3VA.
MID Konformität
Genauigkeit: 0,9 Un ≤ U ≤ 1,1 Un; 0,98 fn ≤ f ≤ 1,02 fn; fn:
50Hz; cosj: 0,5 induktiv bis 0,8 kapazitiv. klasse: B; I st: 0,02A;
I min: 0,25A; I tr: 0,5A; I max: 32A. Betriebstemperatur: -25°C
bis +55°C (13°F bis 131°F) (r.F. von 0 bis 90% nicht kondensierend bei 40°C). EMV Konformität: E2. *Schutzgrad: um den
Schutz gegen Staub und Wasser entsprechend der spezifischen
Normen gemäß MID zu erreichen, muss der Energiezähler in einem
Gehäuse oder Schaltschrank mit Schutzgrad IP51 (oder höher)
installiert werden.
max 100mA. VOFF: 30VCC max. Durée d’impulsion: ≥100ms
<120msec (ON), ≥120ms (OFF), selon EN62052-31. Isolation
au moyen d’optocoupleurs, 4000VRMS de la sortie aux entrées
de mesure.
Température de fonctionnement: de -25°C à +55°C (de 13°F
à 131°F) (H.R. de 0 à 90% sans condensation @ 40°C) selon
EN62053-21 . Température de stockage: de -30°C à +70°C
(de 22°F à 140°F) (H.R. < 90% sans condensation @ 40°C)
selon EN50470-3 . Catégorie d’installation: Cat. III (IEC60664,
EN60664). Isolation (pendant 1 minute) 4000 VRMS entre
entrées de mesure et sortie (O1). 4000VRMS entre alimentation
et sortie logique. Tension diélectrique 4000VRMS pour 1
minute. Émission de bruit: CMRR 100dB, de 48 à 62 Hz EMC
selon EN50470-1. Décharges électrostatiques: 8kV air discharge;
Immunité aux champs électromagnétiques induits. Test avec courant: 10V/m de 80 à 2000MHz; Test sans courant: 30V/m de 80
à 2000MHz; Transitoires sur circuits d’entrées de mesure courant
et tension: 4kV. Immunité aux bruits par conduction 10V/m de
150KHz à 80MHz. Surtension sur circuit d’entrées de mesure
courant et tension: 4kV. Suppression fréquence radio: CISPR
22. Conformité aux standards: sécurité IEC60664, IEC610101 EN60664, EN61010-1 EN50470-1. Métrologie EN50470-3,
EN50470-3. Sortie impulsion DIN43864, IEC62053-31.
Approbations: CE. Connexions: a vis. Section de câble: min.
2,5 mm2, max. 10 mm2 (entrées de mesure), couple de serrage
de vis: 0,5 Nm/1,1 Nm.; autres entrées: 1,5 mm2, couple de
serrage de vis: max 0,5 Nm. Boîtier DIN: dimensions: 17,5 x
90 x 67 mm. Matériau: Nylon PA66, autoextinguible: UL 94 V-0.
Montage: sur rail DIN. *Indice de protection: face avant IP40.
Terminaisons de vis: IP20. Poids: environ 100 g (emballage
inclus). Caractéristiques de l’alimentation: 230 VLN (-20%
+20%) 48-62Hz. Version auto-alimentée: ≤ 3VA.
Conformité à MID
Précision 0,9 Un ≤ U ≤ 1,1 Un; 0,98 fn ≤ f ≤ 1,02 fn; fn: 50Hz;
cosj: de 0,5 inductif à 0,8 capacitif. Classe B; I st: 0,02A; I min:
0,25A; I tr: 0,5A; I max: 32A. Température de fonctionnement
de -25°C à +55°C (de 13°F à 131°F) (H.R. de 0 à 90% sans
condensation @ 40°C). Conformité CEM: E2. *Indice de
protection: afin d’assurer la protection contre la poussière et
l’eau conformément aux normes MID, le compteur étant IP51, il
est recommandé pour les applications à environnement sévère
d’utiliser un coffret de protection ayant un IP adapté.
MID KONFORMITÄT
CERTIFICATION
Lt. gesetzlichen Richtlinen des Messwesen müssen
alle EM10 Modelle nach Anhang D bzw. Anhang II
Module “D” oder “F” der MID-Richtlinie zertifiziert werden. ACHTUNG: aus rechtlichen Gründen muss die
ordnungsgemäße Eichkennzeichnung gefolgt von der
ID-Nummer, des Zertifizierers nach Anhang II Modul
“D” oder jener Eichstelle Anhang II Modul “F” am
Zähler aufgedruckt / aufgeklebt werden.
Pour la métrologie légale, tous les modèles EM10 doivent, en complément, être certifiés en accord avec
l’Annexe II modules “D” ou “F” de la Directive MID.
ATTENTION: le logo type métrologique suivi du numéro
d’identification se référant à l’Annexe II module “D”
ou à l’Annexe II module “F” doit être imprimé/collé
sur le compteur.
!
HINWEIS: Um eine korrekte Funktion des
Energiezählers zu gewährleisten ist es notwendig, das die Schrauben entsprechend dem angegebenen Anzugsmoment angezogen werden.
!
ATTENTION: Pour le bon fonctionnement du
produit, s’assurer que les vis des bornes sont
serrées avec le bon couple de serrage comme
indiqué.
del pulso≥100ms <120msec (ON), ≥120ms (OFF), según norma
EN62052-31. Aislamiento mediante optoacopladores 4000VRMS
entre salida y entrada de medida. Temperatura de trabajo:
de -25°C a +55°C (de 13°F a 131°F) (H.R. de 0 a 90% sin
condensación @ 40°C) según EN50470-3 . Temperatura almacenamiento: de -30°C a +70°C (de 22°F a 140°F) (H.R. < 90%
sin condensación @ 40°C) según EN62053-21 . Categoría
de la instalación: Cat. III (IEC60664, EN60664). Aislamiento
(durante 1 minuto) 4000 VRMS entre entradas de medida y
salida digital (O1). 4000 VRMS entre alimentación y salida digital.
Resistencia dieléctrica: 4000 VRMS por 1 minuto. Rechazo al
ruido CMRR 100 dB, de 48 a 62 Hz EMC según EN50470-1.
Descargas electrostáticas: 8kV descarga en el aire; Inmunidad a
los campos electromagnéticos. Prueba con intensidad: 10V/m de
80 a 2000MHz; Prueba sin intensidad: 30V/m de 80 a 2000MHz;
Ráfagas: en el circuito de entradas de medida de intensidad
y tensión: 4kV. Immunidad a las perturbaciones conducidas:
10V/m de 150KHz a 80MHz. Tension de pulso en el circuito de
entradas de medida de intensidad y tensión: 4kV. Emisiones
de radiofrecuencia según norma CISPR 22. Conformidad
con las normas: seguridad IEC60664, IEC61010-1 EN60664,
EN61010-1 EN50470-1. Metrología EN62053-21, EN50470-3.
Salida de pulso DIN43864, IEC62053-31 Homologaciones:
CE. Conexiones: a tornillo. Sección del cable: Mín. 2,5 mm2,
Máx. 10 mm2 (entradas de medida), par de apriete: 0,5 Nm/1,1
Nm.; otras entradas: 1,5 mm2, par de apriete: max 0,5 Nm. Caja
DIN: dimensiones: 17,5 x 90 x 67 mm. Material: Nylon PA66,
autoextinguible: UL 94 V-0. Montaje: carril DIN. *Grado de protección: panel frontal IP40. Conexiones: IP20. Peso: aprox. 100
g (embalaje incluido). Autoalimentación: 230 VLN (-20% +20%)
48-62Hz. Consumo de potencia: ≤ 3VA.
Conformidad MID
Precisión 0,9 Vn ≤ V ≤ 1,1 Vn; 0,98 fn ≤ f ≤ 1,02 fn; fn: 50Hz;
cosj: de 0,5 inductiva a 0,8 capacitiva. Clase B; I st: 0,02A; I min:
0,25A; I tr: 0,5A; I max: 32A. Temperatura de trabajo de -25°C
a +55°C (de 13°F a 131°F) (H.R. de 0 a 90% sin condensación
a 40°C). Compatibilidad electromagnética (EMC): E2. *Grado
de protección: Con el fin de alcanzar la protección contra polvo
y agua requerida por las normas armonizadas según MID, el
medidor debe instalarse sólo en armarios con protección IP51
o superior.
EN CUMPLIMIENTO CON LA DIRECTIVA MID
Para su uso en mediciones legales, todos modelos EM10
deben estar certificados además según el Anexo II módulos “D” o “F de la directiva MID. ¡ATENCIÓN! Por razones
legales, la marca indicadora de metrología seguida del
número ID en referencia a la etiqueta del Anexo II módulo
“D” de la entidad notificadora o de verificación del
Anexo II módulo “F” debe estar impresa/adherida en el
medidor.
!
ATENCIÓN: Para asegurar el correcto funcionamiento del equipo es necesario atenerse al
especificado par de apriete del tornillo.

Related manuals