Allen-Bradley 800H / HL Illuminated Device Guide d'installation
PDF
Скачать
Документ
Illuminated Device Installation and Mounting Instructions Instructions lumineuses d'installation et de support de dispositif Instrucciones iluminadas de la instalación y del montaje del dispositivo (Cat 800H-_ _ _ , 800HL-_ _ _ ) WARNING To prevent electrical shock, disconnect from power source before installing or servicing. NOTICE Enclosure must comply with U.L. standard 698 and CSA standard C22.2 No 30 for Class I Groups B, C and D hazardous locations or C22.2 No. 25 for Class II Groups E, F and G hazardous locations. For GROUP B locations, seal fitting required within 18 inches on suitable Allen-Bradley base. Lens must be assembled to operator for use in Class I, Division 1 hazardous locations. REMARQUE La clôture doit être conforme à la norme 698 de U.L. et à la norme de CSA C22.2 numero 30 pour la classe I groupe B, C et D ou C22.2 numero 25 pour La classe II groupe E, de F et G. Pour les endroits dangereux pour les location de GROUPE B, ajustage de précision de joint requis à moins de 18 pouces sur la base appropriée d'Allen-Bradley. 1/2" (12.7 mm) Minimum Minimo Les lentilles doit etre assembler pour l’utilisation dans des localités dangereuses de la Classe I Division 1 NOTA El alojamiento debe cumplir con la norma 698 de UL y la norma de CSA C22.2 numero 30 para localidades peligrosas Clase I Grupos B,C y D oC22.2 No. 25 Clase II Grupos E,Fy G. Para localidades Grupo B, se requiere de aditamento de sellado dentro de 18 pulgadas de la base Allen-Bradley disponible 1/2" (12.7 mm) Minimum Minimo Los lentes deben ensamblarse al operador para uso en localidades peligrosas Clase I Div 1 800H- PP, QP, PPT, QPT, PPB, QPB, FPX 800H-LP 3/8”... 23/32” (9.52mm ... 18.25mm) 800HL- PP, QP, PPT, QPT, PPB, QPB, FPX, LP 23/32” ... 29/32” (18.25mm ... 23.01mm) 29/32” ... 1” (23.01mm ... 25.4mm) PN-111716 DIR 10000183966 (Version 01) Printed in U.S.A. 1” ... 2” (25.4mm ... 50.8mm) 2” ... 2 1/2” (50.8mm ... 63.5mm) 1 2 1 Ø .958” / .970” 2 Grease Graisse Grasa 3/4-14 NPSM 2 1 11/32" (8.7 mm) [4 - 5 Threads] 3 1 2 9/32" (7.1 mm) [3 - 4 Threads] 2 800H-Y_ _ 17 - 23 lb-in (1.92 - 2.59 Nm) 17 - 23 lb-in (1.92 - 2.59 Nm) 5 4 800H/ 800HL -PT -PPB -QPB -FPX 1 “Click” PN-111716 DIR 10000183966 (Version 01) 7 - 8 lb-in (.79 - .90 Nm) (2) 2 Assembly of Contact Blocks Illuminated Units: 800_-_P...AAA Position 1 Position 3 Position 4 NOTE: Power module is located in Position 2 No. of Standard Contacts 1-NO, 1-NC 800TXA Code A 1-NO, 1-NCLB 2-NO 2-NC 1-NC, 1-NCLB 1-NO 1-NC 1-NOEM XA1 XA2 XA4 XA7 XD1 XD2 XD3 B M N C D E G 1-NCLB 1-SMCB XD4 XD4S 3 J MaxDuty 800T- Code XD1M XD2M 1 2 XD4M 4 Mini Blocks 800T- XD5 XD6 PenTUFF Code 800TXAV K L Code F XD1V XD2V XD3V H U I XD4V Q Power Module Position 2 Position 1 Position 4 Position 3 Logic Reed 800TXAR Code T XA2R XA4R Y Z XD1R XD2R V W Additional contacts cannot be stacked on XA2, XA2R, XD5 and XD6 contact blocks. Block Type Cat No. Wire Range Tight Torque AWG lb-in Comments (mm2) (Nm) 14 - 18 (.5 - 2.5) 6-8 (.7 - .9) 14 - 18 (.5 - 2.5) 6-8 (.7 - .9) High current. Horsepower rated. Short Circuit Rating: 5KA, 240VAC when protected by fuses. 10 - 18 (.5 - 6.0) 6-8 (.7 - .9) Requires special screw provided with blocks 14 - 18 (.5 - 2.5) 6-8 (.7 - .9) 14 - 18 (.5 - 2.5) 6-8 (.7 - .9) 14 - 18 (.5 - 2.5) 6-8 (.7 - .9) 800T-XAR, XA2R, XA4R 800T-XD1R, XD2R 14 - 18 (.5 - 2.5) 6-8 (.7 - .9) 800T/TC-XAV, XD1V, XD2V, XD3V, XD4V 14 - 18 (.5 - 2.5) 6-8 (.7 - .9) Standard 800T/TC-XD1, 2, 3, 4 800T/TC–XA, 1, 2, 4, 7 Self Monitoring 800TC-XD4S MaxDuty 800T/TC-XD1M, -XD2M, -XD4M Mini 800T-XD5, 6 Sealed — Hi Current 800T-XAP, XD1P, XD2P Sealed — Medium Current 800T-XAY, XA2Y, XA4Y 800T-XD1Y, XD2Y Sealed — Logic Reed PenTUFF Series A (large profile, no longer available) Series B & later (shallow profile) Requires special screw (extended head) provided with blocks. Note: For two circuit contact blocks, it is recommended that the same wire size be used for each circuit. PN-111716 DIR 10000183966 (Version 01) (3) Sealed Switch Stackable Sealed Switch 800TXAP 800TXAY Code 7 XA2Y XA4Y 8 9 XD1Y XD2Y 5 6 XD1P XD2P Code P R S Operator / Color Cap Compatibility Device Type Pilot Light, Pigtail Type Pilot Light, Standard Type Pilot Light, Push-to-Test Type Illuminated Push Button Illuminated Push-Pull PN-111716 DIR 10000183966 (Version 01) Printed in U.S.A. Operator Cat. No. 800H-LP* 800HL-LP* 800H-PP*, 800H-QP* 800HL-PP*, 800HL-QP* 800H-PPT*, 800H-QPT* 800HL-PPT*, 800HL-QPT* 800H-PPB*, 800H-QPB* 800HL-PPB*, 800HL-QPB* 800H-FPX* 800HL-FPX* Color Cap Cat. No. 800H-N104* 800H-N104* 800H-N105* 800H-N106* 800H-NP50* ">

Публичная ссылка обновлена
Публичная ссылка на ваш чат обновлена.