Mitsubishi Electric QD77MS2/QD77MS4/QD77MS16 Manuel du propriétaire
Ajouter à Mes manuels1 Des pages
◉
Touch to zoom
*7 Do not connect to any of the terminal explained as "No connect". *8 Set the external command signal [DI, FLS, RLS, DOG, STOP] in "[Pr.80] External input signal selection" and "[Pr.95] External command signal selection" at QD77MS16 use. *9 Do not use 1A20, 1A19, 1A(B)15 and 1A(B)14 for other than the power supply of manual pulse generator. BCN-B62008-300-G(2303)MEE QD77MS2 QD77MS4 QD77MS16 The table below shows applicable external input wiring connector. When wiring, use applicable wires. Before Using the Product Please read this document before use. Keep this for future reference and make sure that end users will read this. External input wiring connector Wire Model Tightening torque Diameter Type Material Temperature rating Related manuals A6CON1 0.20 to 0.29 N⋅m AWG22 Stranded Copper 75 or more Before using the product, please read "Safety Guidelines" that is supplied with the Main base unit. Confirm the following descriptions: ●SAFETY PRECAUTIONS ●CONDITIONS OF USE FOR THE PRODUCT ●EMC AND LOW VOLTAGE DIRECTIVES ●WARRANTY A6CON2 AWG24 A6CON4 AWG22 Affectation des signaux au connecteur de raccordement d'entrée externe Connecteur de raccordement d'entrée externe (côté module) Manuels associés Avant d'utiliser ce produit, prenez la peine de lire les "Consignes de sécurité" fournies avec l'unité de base principale. Revoir les points suivants : ●PRÉCAUTIONS DE SÉCURITÉ ●CONDITIONS D'UTILISATION DU PRODUIT ●DIRECTIVES EMC ET BASSE TENSION ●GARANTIE Details of the product are also described in the manual shown below (sold separately). Please read the manual and understand the functions and performance of the product to use it correctly. • MELSEC-Q QD77MS Simple Motion Module User's Manual (Positioning Control) IB-0300185 (1XB947) • MELSEC-Q/L QD77MS/QD77GF/LD77MS/LD77MH Simple Motion Module User's Manual (Synchronous Control) IB-0300174 (1XB943) Packing list *2 *2 Numéro Nom du signal de broche Numéro Nom du signal de broche 1B20 Générateur d'impulsions manuel/Encodeur synchrone incrémentiel Phase B/SIGN (HB)*3*4*5 1A20 Sortie alimentation générateur d'impulsions manuel (+5VDC) (5V)*9 1B19 Générateur d'impulsions manuel/Encodeur synchrone incrémentiel Phase A/PLS (HA)*3*4*5 1A19 Sortie alimentation générateur d'impulsions manuel (+5VDC) (5V)*9 1B18 Générateur d'impulsions manuel/Encodeur synchrone incrémentiel Phase B/SIGN (HBL)*3*4*6 1A18 Générateur d'impulsions manuel/Encodeur synchrone incrémentiel Phase B/SIGN (HBH)*3*4*6 1B17 Générateur d'impulsions manuel/Encodeur synchrone incrémentiel Phase A/PLS (HAL)*3*4*6 1A17 Générateur d'impulsions manuel/Encodeur synchrone incrémentiel Phase A/PLS (HAH)*3*4*6 1B16 Non connecté*7 1A16 Non connecté*7 1B15 Sortie alimentation générateur d'impulsions manuel (+5VDC) (5V)*9 1A15 Sortie alimentation générateur d'impulsions manuel (+5VDC) (5V)*9 1B14 Sortie alimentation générateur d'impulsions manuel (GND) (SG)*9 1A14 Sortie alimentation générateur d'impulsions manuel (GND) (SG)*9 1B13 Non connecté*7 1A13 Non connecté*7 *1 Axe4 (AX4) Axe3 Axe2 (AX3) (AX2) Axe1 (AX1) 2B20 2B19 2B18 2B17 2B16 2B15 2B14 2B13 2B12 2B11 2B10 2B9 2B8 2B7 2B6 2B5 2B4 2B3 2B2 2B1 2A20 2A19 2A18 2A17 2A16 2A15 2A14 2A13 2A12 2A11 2A10 2A9 2A8 2A7 2A6 2A5 2A4 2A3 2A2 2A1 1A20 1A19 1A18 1A17 1A16 1A15 1A14 1A13 1A12 1A11 1A10 1A9 1A8 1A7 1A6 1A5 1A4 1A3 1A2 1A1 1B20 1B19 1B18 1B17 1B16 1B15 1B14 1B13 1B12 1B11 1B10 1B9 1B8 1B7 1B6 1B5 1B4 1B3 1B2 1B1 Vue de l'avant du module Check that the following items are included in the package. Item Quantity Module 1 "Before Using the Product" (this document) 1 Operating ambient temperature *1 1B12 1A12 1B11 1A11 Use the product within the range from 0 to 55. 1B10 1A10 Température ambiante de fonctionnement 1B9 1A9 Utiliser le produit à une température ambiante entre 0 et 55. Signal layout for external input connection connector External input connection connector (module side) *2 *2 Axis4 (AX4) Axis3 Axis2 (AX3) (AX2) Axis1 (AX1) 2B20 2B19 2B18 2B17 2B16 2B15 2B14 2B13 2B12 2B11 2B10 2B9 2B8 2B7 2B6 2B5 2B4 2B3 2B2 2B1 2A20 2A19 2A18 2A17 2A16 2A15 2A14 2A13 2A12 2A11 2A10 2A9 2A8 2A7 2A6 2A5 2A4 2A3 2A2 2A1 1A20 1A19 1A18 1A17 1A16 1A15 1A14 1A13 1A12 1A11 1A10 1A9 1A8 1A7 1A6 1A5 1A4 1A3 1A2 1A1 1B20 1B19 1B18 1B17 1B16 1B15 1B14 1B13 1B12 1B11 1B10 1B9 1B8 1B7 1B6 1B5 1B4 1B3 1B2 1B1 Front view of the module Pin Signal name number Pin Signal name number 1B20 Manual pulse generator/Incremental synchronous encoder Bphase/SIGN (HB)*3*4*5 1A20 1B19 Manual pulse generator/Incremental synchronous encoder Aphase/PLS (HA)*3*4*5 1A19 Manual pulse generator power supply output (+5VDC) (5V)*9 1B18 Manual pulse generator/Incremental synchronous encoder Bphase/SIGN (HBL)*3*4*6 1A18 Manual pulse generator/Incremental synchronous encoder Bphase/SIGN (HBH)*3*4*6 1B17 Manual pulse generator/Incremental synchronous encoder Aphase/PLS (HAL)*3*4*6 1A17 Manual pulse generator/Incremental synchronous encoder Aphase/PLS (HAH)*3*4*6 1B16 No connect*7 1A16 No connect*7 1B15 Manual pulse generator power supply output (+5VDC) (5V)*9 1A15 Manual pulse generator power supply output (+5VDC) (5V)*9 1B14 Manual pulse generator power supply output (GND) (SG)*9 1A14 Manual pulse generator power supply output (GND) (SG)*9 1B13 No connect*7 1A13 No connect*7 *1 1B8 Signal d'entrée d'arrêt forcé Commun (EMI.COM) 1A8 Signal d'entrée d'arrêt forcé (EMI) 1B7 Commun (COM) 1A7 Commun (COM) 1B6 Commun (COM) 1A6 Commun (COM) 1B5 Signal de commande externe/signal de commutation (DI2)*8 1A5 Signal de commande externe/signal de commutation (DI1)*8 1B4 Signal d'arrêt (STOP)*8 1A4 1B3 Signal de surveillance 1A3 point d'approche (DOG)*8 Signal de surveillance point d'approche (DOG)*8 1B2 Signal de limite inférieure (RLS)*8 1A2 Signal de limite inférieure (RLS)*8 1B1 Signal de limite supérieure (FLS)*8 1A1 Signal de limite supérieure (FLS)*8 *1 1B12 1A12 1B11 1A11 1B10 1A10 1B9 1A9 Manual pulse generator power supply output (+5VDC) (5V)*9 *1 1A(B)20 à 1A(B)1 correspondent aux bornes d'axe 1 et d'axe 2 du connecteur. Pour les bornes 2A(B)20 à 2A(B)1 des axes 3 et 4, voir 1A(B)20 à 1A(B)1. Cependant, les bornes 2A(B)20 à 2A(B)8 sont "Non connecté", 2A5 est "DI3", et 2B5 est "DI4". *2 Le QD77MS2 n'a pas de connecteur AX3 et AX4 sur le côté gauche. *3 Le type d'entrée en provenance du générateur d'impulsions manuel/encodeur synchrone incrémentiel permute en mode "[Pr.89] Manual pulse generator/Incremental synchronous encoder input type selection". (Seule la valeur spécifiée pour axe 1 est valide.) ⋅ 0: Type différentiel-sortie ⋅ 1: Type tension-sortie/ouvert-collecteur (valeur par défaut) *4 Adopter une forme d'entrée de signal dans "[Pr.24] Manual pulse generator/Incremental synchronous encoder input selection". *5 Type tension-sortie/ouvert-collecteur du générateur d'impulsions manuel/encodeur synchrone incrémentiel: Raccorder le signal Phase A/PLS sur HA, et le signal Phase B/SIGN sur HB. *6 Type différentiel-sortie du générateur d'impulsions manuel/encodeur synchrone incrémentiel: Raccorder le signal Phase A/PLS sur HAH, et le signal Phase A/PLS inversé sur HAL. Raccorder le signal Phase B/SIGN sur HBH, et le signal Phase B/SIGN inversé sur HBL. *7 Ne rien raccorder à aucune des bornes portant la mention "Non connecté". *8 Régler le signal de commande externe [DI, FLS, RLS, DOG, STOP] dans "[Pr.80] External input signal selection" et "[Pr.95] External command signal selection" pour utiliser un QD77MS16. *9 Ne pas utiliser 1A20, 1A19, 1A(B)15 et 1A(B)14 dans un but autre que l'alimentation du générateur d'impulsions manuel. Le tableau ci-dessous indique quels connecteurs on peut utiliser comme connecteur de câblage des entrées externes. Pour le câblage, utiliser les fils prescrits. 1B8 Forced stop input signal common (EMI.COM) 1A8 Forced stop input signal (EMI) 1B7 Common (COM) 1A7 Common (COM) 1B6 Common (COM) 1A6 Common (COM) 1B5 External command signal/switching signal (DI2)*8 1A5 External command signal/ switching signal (DI1)*8 1B4 Stop signal (STOP)*8 1A4 Stop signal (STOP)*8 A6CON2 AWG24 1B3 Proximity dog signal (DOG)*8 1A3 Proximity dog signal (DOG)*8 A6CON4 AWG22 1B2 Lower limit signal (RLS)*8 1A2 Lower limit signal 1B1 Upper limit signal (FLS)*8 1A1 Upper limit signal (FLS)*8 Signal d'arrêt (STOP)*8 Connecteur de câblage des entrées externes Fil Modèle Couple de serrage Diamètre Type Matériau Classe de température A6CON1 0,20 à 0,29 N⋅m AWG22 Torsadé Cuivre 75 ou plus (RLS)*8 *1 1A(B)20 to 1A(B)1 indicates the case of axis 1 and axis 2 terminals of the connector. For the 2A(B)20 to 2A(B)1 terminals of axis 3 and axis 4, refer to 1A(B)20 to 1A(B)1. However, the 2A(B)20 to 2A(B)8 terminals are "No connect", 2A5 is "DI3", and 2B5 is "DI4". *2 QD77MS2 does not have AX3 and AX4 connector on the left side. *3 Input type from manual pulse generator/incremental synchronous encoder is switched in "[Pr.89] Manual pulse generator/Incremental synchronous encoder input type selection". (Only the value specified against the axis 1 is valid.) ⋅ 0: Differential-output type ⋅ 1: Voltage-output/open-collector type (Default value) *4 Set the signal input form in "[Pr.24] Manual pulse generator/Incremental synchronous encoder input selection". *5 Voltage-output/open-collector type of manual pulse generator/incremental synchronous encoder: Connect the A-phase/PLS signal to HA, and the B-phase/SIGN signal to HB. *6 Differential-output type of manual pulse generator/incremental synchronous encoder: Connect the A-phase/PLS signal to HAH, and the A-phase/PLS inverse signal to HAL. Connect the B-phase/SIGN signal to HBH, and the B-phase/SIGN inverse signal to HBL. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN NAGOYA WORKS: 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA 461-8670, JAPAN QD77MS-U-HW