John D.

What is the procedure for programming the operator after a reset or during initial setup?
To program the operator, program the OPEN position by moving the door to that position and memorizing it. Then, program the CLOSED position by moving the door to that position and memorizing it. Finally, program the remote control by activating the handheld transmitter, releasing it, and memorizing the remote.
D I

John D.

What action should be performed after programming the operator?
A functional check should be performed after programming.
D I

John D.

How can the operator be reset to its factory default settings?
The operator can be reset to factory settings via 'Menu 11 – REINITIALISATION'.
B H

Linda B.

What to do if the gate blocks while closing?
If the gate blocks while closing, check the gate's movement for difficulties or irregularities, and lubricate if necessary. Consider having the automatic stop checked by a specialist and consider adjusting settings in menus 5 and 6. Inspect the photocell for obstructions or malfunctions. Verify and readjust the gate's 'CLOSE' position settings, and check the gate itself.
D I

John D.

How to program the Programmer Confort 50?
To correctly commission the operator and after a reset, it is necessary to perform quick programming. First, program the OPEN position by bringing the door to that position and memorizing it. Then, program the CLOSED position by bringing the door to that position and memorizing it. Finally, program the remote control by pressing the hand-held transmitter, then releasing it and memorizing the remote control. A functional check should be carried out after quick programming.
D I

John D.

How to reset the Programmer Confort 50 to factory settings?
It is possible to return to factory settings by performing a reset via « Menu 11 – REINITIALISATION ».
B H

Linda B.

What to do if the gate blocks while closing?
If the gate blocks while closing, possible causes include: the gate running irregularly or being blocked, the automatic stop being too sensitive, the photocell being interrupted or defective, or the gate positions being incorrectly set. Check the gate movement and lubricate if necessary. A specialist dealer can check the automatic stop. Check for obstacles blocking the photocell or have the photocell checked. Check the gate positions and readjust if necessary.
B H

Linda B.

What are the possible causes of a gate blocking while closing and how can they be resolved?
If the gate blocks while closing, possible causes and solutions include: Difficult or uneven gate movement (lubricate the gate); overly sensitive automatic stop (have it checked by a specialist; photoelectric sensor interruption (check for obstructions or sensor defects); and incorrect gate position settings (check and readjust the OPEN and CLOSURE positions and inspect the gate).