User questions

E Q

Patricia E.

Can the NTC probe be replaced by the user or an installer?

Yes, it can. The NTC probe is a replaceable part. Typically, it plugs into a socket on the main circuit board. To replace it, you would disconnect the old probe and connect the new one, ensuring it's properly seated. It's recommended that this procedure be performed by a qualified technician or installer to ensure proper installation and avoid potential damage or safety issues.

N T

Linda N.

How to react to a safety alarm or error code on the boiler?

Identify the error code on the display. For certain codes such as E01, E02, or E35, the system can be reset by holding the RESET button for at least 2 seconds.

N T

Linda N.

What should be done if the boiler emits an alarm or an error code is displayed?

Identify the error code on the screen and consult the official safety signaling table. For certain codes (such as E01, E02, or E35), the boiler can be reset by pressing the RESET button for at least 2 seconds.

W U

James W.

What checks should be performed if the boiler indicates a malfunction or error code?

Identify the numerical error code displayed on the screen (e.g., E10). Check the manometer to ensure the water pressure is between 0.7 and 1.5 bar; use the filling valve if the pressure is too low. To restart the boiler after a safety shutdown, press and hold the 'R' (Reset) key for at least 2 seconds.

W U

James W.

What steps should be taken if the boiler displays an error code?

Identify the error code on the display and check the water pressure on the manometer to ensure it is between 0.7 and 1.5 bar. If necessary, restart the boiler by pressing the 'R' (Reset) button for at least 2 seconds.

W U

James W.

What should be done if the boiler displays an error code or an anomaly?

Check the digital display to identify error codes (such as E01 or E10). Ensure the water pressure on the manometer is between 0.7 and 1.5 bar, using the filling tap if necessary. To restart the boiler after a safety shutdown, press and hold the reset (R) button for at least 2 seconds.

W U

James W.

What to do if the boiler displays an error code or experiences a malfunction?

Check the digital display for error codes (such as E10). Ensure that the water pressure on the gauge is between 0.7 and 1.5 bar; use the filling valve to adjust it if necessary. To restart the boiler after a safety shutdown, press the Reset (R) button for at least 2 seconds.

G F

Robert G.

What does error code E03 mean?

Error code E03 indicates a tripping of the flue gas thermostat or flue pressure switch.

U E

Michael U.

How to turn on the heating mode on a boiler?

Turn on the boiler power supply and open the gas valve. Press the mode selection button for at least 2 seconds, select WINTER or HEATING ONLY mode, and adjust the heating flow temperature using the corresponding +/- buttons.

U E

Michael U.

How to turn on the heating mode on the boiler?

  1. Turn on the power supply to the boiler and open the gas valve.
  2. Press and hold the operating mode selection key for at least 2 seconds.
  3. Select WINTER mode (heating + domestic hot water) or HEATING ONLY.
  4. Set the heating flow temperature using the corresponding +/- keys.