DONNÉES TECHNIQUES ET PERFORMANCES STANDARD - R407C
Performances en mode chauffage standard AS-7M5
MODELE
14
18
21
25
32
37
50
60
Tw
35
40
45
50
55
35
40
45
45
50
55
50
55
40
45
50
55
35
40
35
40
45
50
55
35
40
45
50
55
35
40
45
50
55
35
40
45
50
55
35
-5 0
TEMPERATURE AIR EXTERIEUR (°C B.S.)
5 7 10 15
kWf kWa kWf kWa kWf kWa kWf kWa kWf kWa kWf kWa
11.7
4.56
12.1
5.12
12.4
5.68
12.8
6.39
13.2
7.05
12.7
4.96
14.6
14.7
14.9
15.1
15.2
15.7
4.67
5.25
5.83
6.56
7.24
5.03
17.4
17.4
17.3
17.1
17.0
18.7
4.78
5.37
6.02
6.77
7.47
5.10
18.6
18.4
17.7
17.9
17.8
19.9
4.82
5.43
5.93
6.84
7.55
5.13
20.3
20.0
19.4
19.3
19.1
21.7
4.89
5.50
6.06
6.93
7.69
5.17
23.2
22.7
22.2
21.8
21.3
24.7
4.99
5.63
6.26
7.08
7.82
5.24
13.1
5.67
13.4
6.38
13.8
7.28
14.2
8.11
14.8
5.98
15.3
6.82
15.9
16.0
16.2
16.3
18.4
18.7
5.73
6.44
7.34
8.16
6.05
6.90
18.7
18.6
18.3
18.2
22.1
22.1
5.80
6.52
7.41
8.22
6.12
6.97
19.8
18.9
19.2
19.0
23.5
23.4
5.82
6.54
7.43
8.24
6.15
7.00
21.4
20.7
20.6
20.4
25.7
25.4
5.86
6.57
7.46
8.28
6.20
7.05
24.2
23.7
23.3
22.8
29.3
28.8
15.8
7.66
16.3
8.74
16.8
9.72
18.1
6.88
18.6
7.84
19.0
8.80
19.5
10.0
20.0
11.1
22.0
8.72
22.7
9.84
23.3
11.0
24.0
12.4
24.7
13.7
26.5
10.0
27.1
11.3
27.6
12.7
28.2
14.4
28.7
16.0
36.8
13.9
37.8
15.8
38.8
17.7
39.7
20.1
40.7
22.4
46.6
16.5
47.7
18.6
48.9
20.7
50.0
23.4
51.2
25.8
18.9
19.2
19.4
22.1
22.3
22.5
22.7
22.9
27.8
28.1
28.3
28.6
28.8
33.0
33.1
33.2
33.4
33.5
45.7
46.2
46.7
47.2
47.7
56.6
57.3
58.0
58.7
59.5
7.74
8.83
9.81
6.96
7.93
8.91
10.2
11.3
8.91
10.0
11.2
12.6
13.9
10.2
11.6
12.9
14.7
16.3
14.1
16.0
17.9
20.4
22.7
16.7
18.9
21.0
23.8
26.4
22.1
21.8
21.7
26.1
26.1
26.0
25.7
25.6
33.6
33.5
33.3
32.7
32.5
39.4
39.2
38.9
38.1
37.7
54.6
54.6
54.6
53.9
53.9
66.7
66.9
67.2
66.6
66.8
7.85
8.93
9.92
7.03
8.03
9.06
10.3
11.5
9.10
10.2
11.5
12.9
14.3
10.4
11.8
13.3
15.1
16.7
14.3
16.2
18.2
20.7
23.0
16.9
19.1
21.5
24.4
27.0
22.6
22.8
22.7
27.7
27.6
26.6
26.9
26.7
36.0
35.6
34.4
34.4
34.0
42.0
41.6
40.2
40.0
39.5
58.1
58.0
56.2
56.8
56.5
70.7
70.8
69.4
69.9
69.9
7.84
8.97
10.0
7.06
8.06
9.14
10.4
11.6
9.17
10.3
11.5
13.0
14.4
10.5
11.9
13.3
15.2
16.8
14.3
16.3
18.3
20.8
23.1
17.0
19.3
21.8
24.6
27.3
24.7
7.90
24.6
9.01
24.4
30.2
10.0
7.11
29.8
8.12
29.0
28.9
28.6
39.4
9.28
38.9
10.5
37.7
11.6
37.2
13.1
36.7
9.18
10.4
11.7
14.6
45.9
10.7
45.2
12.1
43.9
13.5
43.2
15.3
42.6
17.1
63.5
14.5
63.0
16.4
61.6
18.4
61.3
21.0
61.0
23.3
76.7
17.1
76.6
19.4
75.5
21.9
75.3
24.8
75.2
27.6
28.3
27.8
27.2
34.2
33.6
33.0
32.5
31.9
45.3
44.3
43.3
42.3
41.3
71.4
70.5
69.6
68.7
86.8
52.4
51.2
50.1
49.0
47.9
72.3
86.2
85.6
85.0
84.4
16.7
18.7
21.2
23.5
17.3
10.9
12.3
13.8
15.6
17.3
14.7
19.7
22.1
25.2
28.0
9.47
10.7
11.8
13.4
14.7
7.99
9.09
10.1
7.18
8.21
9.24
10.6
11.8
5.93
6.62
7.51
8.31
6.27
7.13
Tw= Température eau en sortie en °C kWf =Puissance thermique (kW). kWa =Puissance absorbée par le compresseur (kW).