PERFORMANCES DU CHAUFFAGE STANDARD AB - 7M. Ferroli RMA 21 VB, RMA 25 VB, RMA 14 VB, RMA 18 VB, RMA 14 VA, RMA 18 VA, RMA 32 VB, RMA 37 VB, RMA 32 VA, RMA 37 VA
DONNÉES TECHNIQUES ET PERFORMANCES STANDARD - R407C
Performances en mode refroidissement standard AB-7M5
MODELE
14
18
21
25
32
37
Tw
7
8
5
6
9
10
7
8
5
6
9
10
7
8
5
6
9
10
7
8
5
6
9
10
7
8
5
6
9
10
7
8
5
6
9
10
25 30
TEMPERATURE AIR EXTERIEUR (°C B.S.)
35 40 43 46
kWf kWa kWf kWa kWf kWa kWf kWa kWf kWa kWf kWa
16.1
4.73
16.7
4.85
17.1
4.85
17.6
4.85
18.2
4.97
18.8
4.97
15.2
15.7
16.1
16.6
17.1
17.7
5.35
5.35
5.47
5.47
5.47
5.60
14.3
14.7
15.1
15.5
16.1
16.7
5.98
6.10
6.10
6.22
6.22
6.34
13.1
13.5
14.0
14.4
14.8
15.3
6.77
6.89
6.89
7.01
7.01
7.13
12.5
12.9
13.2
13.6
14.0
14.6
7.29
7.42
7.42
7.42
7.54
7.66
11.7
12.1
12.5
12.8
13.2
13.8
7.83
7.95
7.95
8.08
8.08
8.20
16.7
5.26
17.4
5.26
17.9
5.37
18.5
5.37
19.2
5.37
19.6
5.48
15.8
16.4
17.0
17.6
18.1
18.6
5.80
5.80
5.91
5.91
6.02
6.02
14.9
15.4
16.0
16.5
17.0
17.5
6.45
6.45
6.56
6.56
6.67
6.67
13.8
14.3
14.8
15.3
15.8
16.2
7.26
7.26
7.26
7.37
7.37
7.48
13.1
7.73
13.6
7.73
14.1
7.84
14.6
7.84
15.1
15.5
7.95
7.95
12.4
12.9
13.4
13.9
14.3
14.7
8.20
8.31
8.31
8.42
8.42
8.53
20.4
6.12
21.0
6.22
21.7
6.22
22.3
6.32
23.1
6.32
23.9
6.43
23.8
7.17
24.7
7.17
25.4
7.28
26.1
7.38
26.9
7.38
27.8
7.49
19.2
19.9
20.5
21.2
21.8
22.5
22.6
23.3
24.0
24.7
25.4
26.2
6.85
6.96
6.96
7.06
7.06
7.16
8.03
8.03
8.13
8.24
8.24
8.34
18.1
18.7
19.3
19.8
20.5
21.3
21.1
21.9
22.5
23.2
23.9
24.7
7.59
7.70
7.80
7.80
7.90
8.01
8.99
8.99
9.10
9.21
9.21
9.31
16.7
17.3
17.8
18.4
19.0
19.7
19.5
20.3
20.9
21.5
22.1
22.8
7.65
8.70
8.70
8.81
8.91
8.91
10.0
10.1
10.2
10.4
10.4
10.5
15.9
16.5
17.0
17.5
18.0
18.7
18.6
10.8
19.2
10.9
19.8
10.9
20.4
21.0
21.7
9.17
7.27
9.38
9.38
9.48
9.59
11.0
11.2
11.3
15.1
15.6
16.1
16.6
17.1
17.7
17.7
18.2
18.8
19.4
20.0
20.6
11.5
11.6
11.8
11.9
12.0
12.1
9.8
10.0
10.0
10.1
10.2
10.3
31.2
9.27
32.1
9.37
33.2
9.48
34.2
9.59
35.2
9.69
36.4
9.80
35.9
10.8
37.1
10.9
38.2
39.3
11.0
11.1
40.5
41.9
11.3
11.4
34.0
35.1
36.1
37.2
38.3
39.6
29.5
30.5
31.5
32.4
33.3
34.4
12.0
12.2
12.3
12.4
12.5
12.6
10.3
10.4
10.5
10.6
10.7
10.8
32.0
33.0
34.0
35.0
36.1
37.3
27.8
28.7
29.6
30.5
31.4
32.4
13.4
13.5
13.6
13.7
13.9
14.0
11.4
11.5
11.6
11.7
11.8
11.9
29.6
30.5
31.5
32.4
33.4
34.6
25.8
26.6
27.5
28.4
29.2
30.2
14.9
15.1
15.2
15.3
15.4
15.6
12.6
12.7
12.9
13.0
13.2
13.3
24.6
13.4
25.4
13.6
26.2
13.8
27.0
13.9
27.7
14.0
28.8
14.1
28.2
16.0
29.1
16.1
29.9
16.2
30.9
16.4
31.8
16.5
32.9
16.7
26.7
27.6
28.5
29.3
30.2
31.2
23.3
24.0
24.8
25.6
26.4
27.3
17.0
17.1
17.3
17.5
17.6
17.8
14.4
14.5
14.6
14.7
14.8
15.0
50
60
7
8
5
6
9
10
7
8
5
6
9
10
49.8
51.5
53.1
54.7
56.4
58.0
61.3
63.2
65.1
67.0
68.9
70.8
14.8
15.0
15.2
15.4
15.6
15.8
18.0
18.2
18.5
18.8
19.0
19.3
47.3
48.9
50.5
52.0
53.5
55.1
58.4
60.3
62.2
63.9
65.6
67.3
16.3
16.5
16.8
17.0
17.2
17.4
19.8
20.1
20.5
20.7
20.9
21.2
45.3
46.6
47.9
49.5
51.1
52.7
56.0
57.6
59.3
61.1
62.8
64.6
18.1
18.2
18.4
18.6
18.8
18.9
21.9
22.2
22.5
22.7
22.8
23.0
42.6
42.8
44.1
45.5
46.9
49.5
52.8
52.9
54.7
56.4
58.1
60.8
20.0
20.2
20.4
20.7
20.9
21.1
24.1
24.4
24.7
25.0
25.3
25.6
41.0
40.9
42.2
43.5
44.8
47.6
50.8
50.6
52.2
53.9
55.5
58.6
21.3
21.6
21.8
22.1
22.3
22.6
25.8
26.1
26.4
26.7
27.0
27.4
39.4
40.6
41.9
43.1
44.4
45.7
48.9
50.4
51.8
53.3
54.8
56.3
27.4
27.7
28.1
28.4
28.7
29.1
22.7
23.0
23.2
23.5
23.8
24.0
Tw= Température eau à la sortie en °C kWf = Puissance frigorifique (kW). kWa = Puissance absorbée par le compresseur (kW).