Actassi- S-One RJ45 Network Socket | Schneider Electric Actassi Mode d'emploi
Ajouter à Mes manuels98 Des pages
▼
Scroll to page 2
of
98
How to connect S-One & S-One DPM connectors to reach performance Cat 5e Cat 6 Cat 6A * Power Over Ethernet (Ethernet et alimentation électrique) RJ45 connectors S-One & S-One DPM Installation Sheet GEX94517000 V3 PoE+* 4P PoE IEEE 802.3bt - 100W/52V (1A per pair maximum) 4-pair Power over Ethernet type 4 - IEC 60512-99-002 Download the Acrobat app for a better experience WARNING HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH • This equipment must only be installed by a qualified person. This operation must only be carried out after reading all the instructions in this document. • NEVER work alone. •B efore making the visual inspections, tests or maintenance operations on this equipment, disconnect all electrical power supplies. • Tart off with the principle that all circuits are live until they have been completely powered down, tested and labeled. Pay special attention to the design of the power supply circuit. Take account of all power supply sources, including the possibility of feedback. This instruction must be kept for future use. IMPORTANT NOTE • This equipment be installed, repaired en maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this documentation. • A qualified person is one who has skills and knowledge related to the construction, installation and operation of electrical equipment and who has received safety training to recognize and avoid the hazards involved. • Read this guide carefully and examine the equipment to become familiar with its operation before installing it. • All applicable local, regional, and national regulations must be respected when installing, repairing, and maintaining this equipment. • This device should not be installed if, when unpacking you observe that it is damaged. • Wear suitable personal protective equipment and respect applicable electrical safety instructions. IMPORTANT Plugs compliant with IEC 60603-7 series (RJ45) • Use a Voltage Tester of the appropriate rating. • Take account of possible hazards. Carefully inspect the work area to check that no tools or objects could have been left inside the equipment. Failure to follow these instructions will result in death or serious injury. RJ11 RJ 45 DANGER RISQUE D’ÉLECTROCUTION, D’EXPLOSION OU D’ARC ÉLECTRIQUE • L’installation de cet équipement doit impérativement être réalisée par une personne qualifiée. Cette opération doit être exécutée uniquement en ayant pris connaissance de l’ensemble des instructions du présent document. • Ne travaillez JAMAIS seul. • Avant d’entreprendre des inspections visuelles, des tests ou des opérations de maintenance sur cet équipement, débrancher toutes les sources d’alimentation électrique. • Partez du principe que tous les circuits sont sous tension jusqu’à ce qu’ils aient été mis complètement hors tension, testés et étiquetés. Faites particulièrement attention à la conception du circuit d’alimentation. Tenez compte de toutes les sources d’alimentation, y compris à la possibilité d’une rétroalimentation. La présente instruction de service doit être conservée pour une utilisation future. REMARQUE IMPORTANTE • L’installation, la réparation et la maintenance de cet appareil doivent être assurées uniquement par des personnes qualifiées. Schneider Electric décline toute responsabilité quant aux éventuelles conséquences découlant de l’utilisation de cette documentation. • Une personne qualifiée est une personne disposant de compétences de connaissances en matière de construction, installation et fonctionnement du matériel électrique ayant bénéficié d’une formation de sécurité afin de percevoir et d’éviter les dangers associés. • Lisez attentivement cette instruction de service et examinez l’appareil pour vous familiariser avec son fonctionnement avant de faire son installation. • Toutes les réglementations locales, régionales et nationales applicables doivent être respectées lors de l’installation, réparation et maintenance de cet appareil. • Cet appareil ne doit pas être installé si vous constatez lors du déballage qu’il est endommagé. IMPORTANT Les plugs RJ45 doivent être conformes à la norme IEC 60603-7 séries (RJ45) • Portez un équipement de protection personnelle adapté et respectez les consignes de sécurité électrique courantes. Le non-respect de ces instructions provoquera la mort ou des blessures graves. RJ11 RJ 45 Choice a connector I select the connector Unshielded Shielded Actassi S-One Actassi S-One Actassi S-One DPM Actassi S-One DPM Click on the tab of your choice Choice a connector > Choice a cable S-One Unhielded S-One DPM Unhielded I select the cable Cable U/UTP Cat 5e ≤ 6 mm Cat 6 Click on the tab of your choice Cable U/UTP ≥ 6 mm Cat 6A Choice a connector > Choice a cable S-One Shielded S-One DPM Shielded I select the cable F/UTP U/FTP F/FTP F/FTP (CLMX) SF/UTP Click on the tab of your choice S/FTP Grade 2 TV Grade 3 TV Choice a connector > Choice a cable > Unshielded connector & U/UTP cable Composition (U/UTP) Unshielded connector S-One U/UTP Cat 5e Cat 6 120 mm ≤ 6 mm VDIR580020 x1 S-One DPM 3 1 2 Choice a connector > Choice a cable > Unshielded connector & U/UTP cable 1 2 2 1 60 mm U/UTP x1 3 3 4 2 mm maxi 19 mm Cable preparation Choice a connector > Choice a cable > Unshielded connector & U/UTP cable Connector wiring 11 12 1 U/UTP 2 13 14 19 mm 2 mm U-UTP_cat6A Choice a connector > Choice a cable > Unshielded connector & U/UTP cable Pairs crossing 1 2 3 4 U/UTP How to prepare a U/UTP cable with EIA-TIA 568B to reach high performance EIA-TIA 568B (100Ω) 6 3 2 1 5 4 8 7 Choice a connector > Choice a cable > Unshielded connector & U/UTP cable Pairs crossing 5 6 7 8 U/UTP How to prepare a U/UTP cable with EIA-TIA 568B to reach high performance EIA-TIA 568B (100Ω) 6 3 2 1 5 4 8 7 Choice a connector > Choice a cable > Unshielded connector & U/UTP cable Connector connection U/UTP 1 1 2 Choice a connector > Choice a cable > Unshielded connector & U/UTP cable Connector connection 2 3 U/UTP m 0,5 m maxi mm 0,5 maxi Choice a connector > Choice a cable > Unshielded connector & U/UTP cable Connector disconnection 1 2 3 U/UTP 2 1 2 1 1 2 Choice a connector > Choice a cable > Unshielded connector & U/UTP cable 40 mm 35 mm 27 mm Important: Plugs compliant with IEC 60603-7 series (RJ45) RJ11 41 mm mini RJ 45 Choice a connector > Choice a cable > Unshielded connector & U/UTP cable 7 mm Composition (U/UTP) Unshielded connector S-One U/UTP 120 Cat 6A mm 7 mm VDIR580020 x1 S-One DPM 3 1 2 Choice a connector > Choice a cable > Unshielded connector & U/UTP cable 7 mm 1 2 2 1 60 mm Cable preparation U/UTP x1 3 3 1 3 2 4 Choice a connector > Choice a cable > Unshielded connector & U/UTP cable 7 mm Cable preparation 4 5 19 mm 14 mm U/UTP Ø 7 mm Ø 7 mm Choice a connector > Choice a cable > Unshielded connector & U/UTP cable 7 mm Connector wiring 11 12 1 U/UTP 2 13 5 mm 2 mm 19 mm 14 mm 2 mm 14 Choice a connector > Choice a cable > Unshielded connector & U/UTP cable 7 mm Pairs crossing 1 2 3 4 U/UTP How to prepare a U/UTP cable 7 mm with EIA-TIA 568B to reach high performance EIA-TIA 568B (100Ω) 6 3 2 1 5 4 8 7 Choice a connector > Choice a cable > Unshielded connector & U/UTP cable 7 mm Pairs crossing 5 6 7 8 U/UTP How to prepare a U/UTP cable 7 mm with EIA-TIA 568B to reach high performance EIA-TIA 568B (100Ω) 6 3 2 1 5 4 8 7 Choice a connector > Choice a cable > Unshielded connector & U/UTP cable 7 mm Connector connection U/UTP 1 1 2 Choice a connector > Choice a cable > Unshielded connector & U/UTP cable 7 mm Connector connection 2 3 U/UTP m 0,5 m maxi mm 0,5 maxi Choice a connector > Choice a cable > Unshielded connector & U/UTP cable 7 mm Connector disconnection 1 2 3 U/UTP 2 1 2 1 1 2 Choice a connector > Choice a cable > Unshielded connector & U/UTP cable 7 mm 40 mm 35 mm 27 mm Important: Plugs compliant with IEC 60603-7 series (RJ45) RJ11 41 mm mini RJ 45 Choice a connector > Choice a cable > Shielded connector & F/UTP Composition Shielded connector F/UTP 210 S-One VDIR580020 mm x1 S-One DPM 3 1 2 Choice a connector > Choice a cable > Shielded connector & F/UTP 2 1 F/UTP 3 2 2 20 m m 1 100 mm Cable preparation x1 3 4 5 1 6 2 mm maxi Choice a connector > Choice a cable > Shielded connector & F/UTP Connector wiring 11 2 3 1 F/UTP 2 4 5 2 1 Choice a connector > Choice a cable > Shielded connector & F/UTP Pairs crossing 1 2 3 4 F/UTP How to prepare a F/UTP cable with EIA-TIA 568B to reach high performance EIA-TIA 568B (100Ω) 6 3 2 1 5 4 8 7 Choice a connector > Choice a cable > Shielded connector & F/UTP Pairs crossing 5 6 7 8 F/UTP How to prepare a F/UTP cable with EIA-TIA 568B to reach high performance EIA-TIA 568B (100Ω) 6 3 2 1 5 4 8 7 Choice a connector > Choice a cable > Shielded connector & F/UTP Connector connection F/UTP 1 1 2 Choice a connector > Choice a cable > Shielded connector & F/UTP Connector connection 2 3 F/UTP m 0,5 m maxi mm 0,5 maxi Choice a connector > Choice a cable > Shielded connector & F/UTP Connector disconnection 1 2 3 F/UTP 2 1 2 1 1 2 Choice a connector > Choice a cable > Shielded connector & F/UTP 40 mm 35 mm 27 mm Important: Plugs compliant with IEC 60603-7 series (RJ45) RJ11 41 mm mini RJ 45 Choice a connector > Choice a cable > Shielded connector & U/FTP Composition Shielded connector U/FTP 210 S-One VDIR580020 mm x1 S-One DPM 3 1 2 Choice a connector > Choice a cable > Shielded connector & U/FTP 2 100 mm 1 U/FTP 1 2 3 x1 3 2 30 mm Cable preparation 1 4 Choice a connector > Choice a cable > Shielded connector & U/FTP Pairs crossing 1 2 3 4 U/FTP How to prepare a U/FTP cable with EIA-TIA 568B to reach high performance EIA-TIA 568B (100Ω) 6 3 2 1 5 4 8 7 Choice a connector > Choice a cable > Shielded connector & U/FTP Pairs crossing 5 6 7 8 U/FTP How to prepare a U/FTP cable with EIA-TIA 568B to reach high performance EIA-TIA 568B (100Ω) 6 3 2 1 5 4 8 7 Choice a connector > Choice a cable > Shielded connector & U/FTP Connector wiring 11 2 3 1 U/FTP 2 4 5 2 1 Choice a connector > Choice a cable > Shielded connector & U/FTP Connector connection U/FTP 1 1 2 Choice a connector > Choice a cable > Shielded connector & U/FTP Connector connection 2 3 U/FTP m 0,5 m maxi mm 0,5 maxi Choice a connector > Choice a cable > Shielded connector & U/FTP Connector disconnection 1 2 3 U/FTP 2 1 2 1 1 2 Choice a connector > Choice a cable > Shielded connector & U/FTP 40 mm 35 mm 27 mm Important: Plugs compliant with IEC 60603-7 series (RJ45) RJ11 41 mm mini RJ 45 Choice a connector > Choice a cable > Shielded connector & F/FTP Composition Shielded connector F/FTP 210 S-One VDIR580020 mm x1 S-One DPM 3 1 2 Choice a connector > Choice a cable > Shielded connector & F/FTP 1 2 1 100 mm F/FTP 2 3 x1 3 4 2 30 mm Cable preparation 1 5 Choice a connector > Choice a cable > Shielded connector & F/FTP Pairs crossing 1 2 3 4 F/FTP How to prepare a F/FTP cable with EIA-TIA 568B to reach high performance EIA-TIA 568B (100Ω) 6 3 2 1 5 4 8 7 Choice a connector > Choice a cable > Shielded connector & F/FTP Pairs crossing 5 6 7 8 F/FTP How to prepare a F/FTP cable with EIA-TIA 568B to reach high performance EIA-TIA 568B (100Ω) 6 3 2 1 5 4 8 7 Choice a connector > Choice a cable > Shielded connector & F/FTP Connector wiring 11 2 3 1 F/FTP 2 4 5 2 1 Choice a connector > Choice a cable > Shielded connector & F/FTP Connector connection F/FTP 1 1 2 Choice a connector > Choice a cable > Shielded connector & F/FTP Connector connection 2 3 F/FTP m 0,5 m maxi mm 0,5 maxi Choice a connector > Choice a cable > Shielded connector & F/FTP Connector disconnection 1 2 3 F/FTP 2 1 2 1 1 2 Choice a connector > Choice a cable > Shielded connector & F/FTP 40 mm 35 mm 27 mm Important: Plugs compliant with IEC 60603-7 series (RJ45) RJ11 41 mm mini RJ 45 Choice a connector > Choice a cable > Shielded connector & S/FTP Composition Shielded connector S/FTP 210 S-One VDIR580020 mm x1 S-One DPM 3 1 2 Choice a connector > Choice a cable > Shielded connector & S/FTP 1 2 S/FTP 3 1 100 mm 2 3 x1 25 mm 4 5 6 2 30 mm Cable preparation 1 25 mm x4 Choice a connector > Choice a cable > Shielded connector & S/FTP Pairs crossing 1 2 3 4 S/FTP How to prepare a S/FTP cable with EIA-TIA 568B to reach high performance 6 3 2 1 5 4 8 7 30 mm EIA-TIA 568B (100Ω) Choice a connector > Choice a cable > Shielded connector & S/FTP Pairs crossing 5 6 7 8 S/FTP How to prepare a S/FTP cable with EIA-TIA 568B to reach high performance 6 3 2 1 5 4 8 7 30 mm EIA-TIA 568B (100Ω) Choice a connector > Choice a cable > Shielded connector & S/FTP Connector wiring 1 2 1 S/FTP 2 3 4 Choice a connector > Choice a cable > Shielded connector & S/FTP Connector connection S/FTP 1 1 2 Choice a connector > Choice a cable > Shielded connector & S/FTP Connector connection 2 3 S/FTP m 0,5 m maxi mm 0,5 maxi Choice a connector > Choice a cable > Shielded connector & S/FTP Connector disconnection 1 2 3 S/FTP 2 1 2 1 1 2 Choice a connector > Choice a cable > Shielded connector & S/FTP 40 mm 35 mm 27 mm Important: Plugs compliant with IEC 60603-7 series (RJ45) RJ11 41 mm mini RJ 45 Choice a connector > Choice a cable > Shielded connector & CLMX cable Composition (CLMX) Shielded connector CLMX F/FTP 210 S-One VDIR580020 mm x1 S-One DPM 3 1 2 Choice a connector > Choice a cable > Shielded connector & CLMX cable 1 2 CLMX 3 1 100 mm Cable preparation 2 x1 3 4 5 6 2 28 mm 32 mm 4 1 3 5 Choice a connector > Choice a cable > Shielded connector & CLMX cable Connector wiring 11 2 3 1 CLMX 2 4 5 2 1 Choice a connector > Choice a cable > Shielded connector & CLMX cable Pairs crossing 1 2 3 4 CLMX How to prepare a CLMX cable with EIA-TIA 568B to reach high performance EIA-TIA 568B (100Ω) 6 3 2 1 5 4 8 7 Choice a connector > Choice a cable > Shielded connector & CLMX cable Pairs crossing 5 6 7 8 CLMX How to prepare a CLMX cable with EIA-TIA 568B to reach high performance EIA-TIA 568B (100Ω) 6 3 2 1 5 4 8 7 Choice a connector > Choice a cable > Shielded connector & CLMX cable Connector connection CLMX 1 1 2 Choice a connector > Choice a cable > Shielded connector & CLMX cable Connector connection 2 3 CLMX m 0,5 m maxi mm 0,5 maxi Choice a connector > Choice a cable > Shielded connector & CLMX cable Connector disconnection 1 2 3 CLMX 2 1 2 1 1 2 Choice a connector > Choice a cable > Shielded connector & CLMX cable 40 mm 35 mm 27 mm Important: Plugs compliant with IEC 60603-7 series (RJ45) RJ11 41 mm mini RJ 45 Choice a connector > Choice a cable > Shielded connector & SF/UTP cable Composition Shielded connector SF/UTP 210 S-One VDIR580020 mm x1 S-One DPM 3 1 2 Choice a connector > Choice a cable > Shielded connector & SF/UTP cable 1 2 80 mm SF/UTP 3 1 2 3 x1 30 mm 4 5 6 30 mm Cable preparation 30 mm Choice a connector > Choice a cable > Shielded connector & SF/UTP cable Connector wiring 1 2 1 SF/UTP 2 3 4 Choice a connector > Choice a cable > Shielded connector & SF/UTP cable Pairs crossing 1 2 3 4 SF/UTP How to prepare a SF/UTP cable with EIA-TIA 568B to reach high performance EIA-TIA 568B (100Ω) 6 3 2 1 5 4 8 7 Choice a connector > Choice a cable > Shielded connector & SF/UTP cable Pairs crossing 5 6 7 8 SF/UTP How to prepare a SF/UTP cable with EIA-TIA 568B to reach high performance EIA-TIA 568B (100Ω) 6 3 2 1 5 4 8 7 Choice a connector > Choice a cable > Shielded connector & SF/UTP cable Connector connection SF/UTP 1 1 2 Choice a connector > Choice a cable > Shielded connector & SF/UTP cable Connector connection 2 3 SF/UTP m 0,5 m maxi mm 0,5 maxi Choice a connector > Choice a cable > Shielded connector & SF/UTP cable Connector disconnection 1 2 3 SF/UTP 2 1 2 1 1 2 Choice a connector > Choice a cable > Shielded connector & SF/UTP cable 40 mm 35 mm 27 mm Important: Plugs compliant with IEC 60603-7 series (RJ45) RJ11 41 mm mini RJ 45 Choice a connector > Choice a cable > Shielded connector & Grade 2 TV cable Composition Shielded connector Grade 2 TV 210 S-One VDIR580020 mm x1 S-One DPM 3 1 2 Choice a connector > Choice a cable > Shielded connector & Grade 2 TV cable 1 2 90 mm Grade 2 TV 3 1 4 2 2 Paire 7/8 20 m m Cable preparation 3 1 5 6 20 m m 2 1 7 Choice a connector > Choice a cable > Shielded connector & Grade 2 TV cable Connector wiring 11 2 3 1 Grade 2 TV 2 4 5 2 1 Choice a connector > Choice a cable > Shielded connector & Grade 2 TV cable Pairs crossing 1 2 3 4 Grade 2 TV How to prepare a Grade 2 TV cable with EIA-TIA 568B to reach high performance EIA-TIA 568B (100Ω) 6 3 2 1 5 4 8 7 Choice a connector > Choice a cable > Shielded connector & Grade 2 TV cable Pairs crossing 5 6 7 8 Grade 2 TV How to prepare a Grade 2 TV cable with EIA-TIA 568B to reach high performance EIA-TIA 568B (100Ω) 6 3 2 1 5 4 8 7 Choice a connector > Choice a cable > Shielded connector & Grade 2 TV cable Connector connection Grade 2 TV 1 1 2 Choice a connector > Choice a cable > Shielded connector & Grade 2 TV cable Connector connection 2 3 Grade 2 TV m 0,5 m maxi mm 0,5 maxi Choice a connector > Choice a cable > Shielded connector & Grade 2 TV cable Connector disconnection 1 2 3 Grade 2 TV 2 1 2 1 1 2 Choice a connector > Choice a cable > Shielded connector & Grade 2 TV cable 40 mm 35 mm 27 mm Important: Plugs compliant with IEC 60603-7 series (RJ45) RJ11 RJ 45 Choice a connector > Choice a cable > Shielded connector & Grade 3 TV cable Composition Shielded connector Grade 3 TV 210 S-One VDIR580020 mm x1 S-One DPM 3 1 2 Choice a connector > Choice a cable > Shielded connector & Grade 3 TV cable 1 2 90 mm Grade 3 TV 3 1 4 2 2 Paire 7/8 20 m m 3 1 1 6 7 2 20 mm 5 20 mm Cable preparation Choice a connector > Choice a cable > Shielded connector & Grade 3 TV cable Pairs crossing 1 2 3 4 Grade 3 TV How to prepare a Grade 3 TV cable with EIA-TIA 568B to reach high performance EIA-TIA 568B (100Ω) 6 3 2 1 5 4 8 7 Choice a connector > Choice a cable > Shielded connector & Grade 3 TV cable Pairs crossing 5 6 7 8 Grade 3 TV How to prepare a Grade 3 TV cable with EIA-TIA 568B to reach high performance EIA-TIA 568B (100Ω) 6 3 2 1 5 4 8 7 Choice a connector > Choice a cable > Shielded connector & Grade 3 TV cable Connector wiring 11 2 3 1 Grade 3 TV 2 4 5 2 1 Choice a connector > Choice a cable > Shielded connector & Grade 3 TV cable Connector connection Grade 3 TV 1 1 2 Choice a connector > Choice a cable > Shielded connector & Grade 3 TV cable Connector connection 2 3 Grade 3 TV m 0,5 m maxi mm 0,5 maxi Choice a connector > Choice a cable > Shielded connector & Grade 3 TV cable Connector disconnection 1 2 3 Grade 3 TV 2 1 2 1 1 2 Choice a connector > Choice a cable > Shielded connector & Grade 3 TV cable 40 mm 35 mm 27 mm Important: Plugs compliant with IEC 60603-7 series (RJ45) RJ11 RJ 45 Schneider Electric Industries SAS 35, rue Joseph Monier CS 30323 F - 92506 Rueil Malmaison Cedex Ce produit doit être installé, raccordé et utilisé en respectant les normes et/ou les règlements d’installation en vigueur. En raison de l’évolution des normes et du matériel, les caractéristiques et cotes d’encombrement données ne nous engagent qu’après confirmation par nos services. RCS Nanterre 954 503 439 Capital social 896 313 776 € www.schneider-electric.com This product must be installed, connected and used in compliance with prevailing standards and/or installation regulations. As standards, specifications and designs change from time to time, always ask for confirmation of the information given in this publication. GEX94517000 © 11-2022 Schneider Electric - All rights reserved.