G D

Patricia G.

Why does the roller shutter stop immediately after starting to open?

This behavior can be caused by force detection (obstacle), incorrect limit switch programming, or an interruption in the safety circuit. Check for error messages such as 'ERR FORCE' or 'ERR FIN DE COUR' and observe the H6 LED indicator for diagnostic pulses.

H D

Jennifer H.

Why does the roller shutter stop immediately during the closing phase?

During closing, an immediate stop may be due to a safety edge malfunction (ERR SKS FER), an obstructed photocell (ERR C/PHOTO), incorrect limit switch adjustment, or mechanical resistance triggering the force control (ERR FORCE).

G D

Patricia G.

What causes a roller shutter to stop immediately after starting to move upwards?

This behavior may be caused by the safety force control (Error 'ERR FORCE' or 5 flashes of LED H6) if a mechanical obstacle is detected. It can also occur if the end-limit positions are not correctly programmed or if there is an interruption in the safety circuit.

H D

Jennifer H.

What should be checked if a roller shutter stops or reverses during descent?

Verify that the safety edge (Error 'ERR SKS FER') and the photoelectric cells (Error 'ERR C/PHOTO') are not obstructed or faulty. Additionally, ensure the 'Close' end-limit position is correctly adjusted and that no mechanical resistance is triggering the force control safety feature.

G D

Patricia G.

What should be checked if a roller shutter stops shortly after starting to move up?

If a roller shutter stops after a short movement when moving up, it may be due to a force detection problem or incorrect limit switch configuration. Check for errors via the display: an ERR FORCE detection (5 blinks of LED H6) indicates active force control. If the positions are not correctly programmed or the door is out of the defined area, the system may lock, indicated by an ERR FIN DE COUR. message. An interruption in the safety circuit (stop chain) can also cause untimely stops, indicated by LED H6 blinking once. It is recommended to check for mechanical obstructions.

H D

Jennifer H.

What should be checked if a roller shutter stops shortly after starting to move down?

If a roller shutter stops during descent (closure), check the following: the safety edge (barre palpeuse 1 on X4 or radio system on X20) for ERR SKS FER; ensure the photocell (on X4) is not obstructed or defective if an ERR C/PHOTO occurs; confirm the CLOSURE limit switch position is correctly programmed, as a reset or readjustment via ADJUSTMENT mode may be necessary; and check for mechanical resistance if an ERR FORCE occurs.