Guide d'installation | Legrand 3000 Series Medium Steel Prewired Raceway Manuel utilisateur
Ajouter à Mes manuels2 Des pages
▼
Scroll to page 2
Wiremold Electrical Systems conform to and should be installed and properly grounded in compliance with requirements of the current National Electrical Code, Canadian Electrical Code or codes administered by local authorities. All electrical products may represent possible shock or fire hazard if improperly installed or used. Wiremold electrical products are UL listed. Made for interior use only and should be installed in conformance with current local and/or the National Electrical Code. 3000 Two-Piece Metal Raceway INSTALLATION INSTRUCTIONS 3000 RACEWAY WIRE FILL CAPACITIES FOR DATA/COMMUNICATIONS UNSHIELDED TWISTED PAIR 24 AWG, 4-PAIR TYPE CAT. 5 0.220 [5.6] 37 O.D. inches O.D. [mm] 40% fill TELEPHONE 24 AWG, NO. OF PAIRS CAT. 3 0.190 [4.8] 50 2 0.140 [3.6] 93 3 0.150 [3.8] 81 4 0.190 [4.8] 50 COAXIAL 25 0.410 [10.4] 10 RG58/U 0.195 [5.0] 47 RG59/U 0.242 [6.1] 31 SHIELDED TWISTED PAIR TWINAXIAL RG62/U 0.242 [6.1] 31 RG6/U 0.270 [6.9] 25 100 OHM 0.330 [8.4] 16 TYPE 1 0.390 [9.9] 11 TYPE 2 0.465 [11.8] 8 TYPE 3 0.245 [6.2] 30 FIBER OPTIC TWO STRAND (DUPLEX) MULTIMODE, 62.5/125µm 0.190 [4.8] 50 3000 RACEWAY WIRE FILL CAPACITIES FOR POWER TYPE AWG, THHN/THWN O.D. inches O.D. [mm] 40% fill 2 0.384 9.8 0 4 0.324 8.2 0 6 0.254 6.5 27 WITHOUT DEVICES 8 10 0.216 0.164 5.5 4.2 38 66 12 0.130 3.3 105 14 0.111 2.8 144 2 0.384 9.8 0 4 0.324 8.2 0 WITH DEVICES (SURGE / GFCI) 6 8 10 0.254 0.216 0.164 6.5 5.5 4.2 11 15 26 12 0.130 3.3 42 14 0.111 2.8 58 • Use No. 8 (5/16", 7.9mm head size) flat head fastener or equivalent to mount base to surface. • Grounding: Use ground location when provided or install a suitable ground lug, ring terminal or locknut and ground bushing. • Utiliser une attache à tête plate de calibre 8 (tête de 7.9mm, 5/16" po.) ou une fixation équivalente pour assujettir le tube guide-fils et les raccords à la surface de montage. • Mise à la terre: Utiliser l’emplacement de terre prévu ou poser le matériel qui convient: patte de mise à la terre, cosse circulaire à oeil ou écrou de blocage et manchon de terre. • Use un sujetador de cabeza plana No. 8 (tamaño de cabeza: 7.9mm, 5/16" de pulgada) o su equivalente para unir la canalita y los accesorios a la superficie de montaje. • Conexión a tierra: Use un localizador de tierra cuando se proporcione o instale una orejeta de tierra, anillo terminal o contratuerca y cojinetes de tierra apropiados. 630B 630C 3000B 3000C 3000WC 9.4" [23.9cm] Precut Covers 3001A 3001 3007C 3000C075 = 12" [30.5 cm] 3000C195 = 24" [60.9 cm] 1 3008C 2 3010AE 3 1.5" [38mm] 3010C 2" [51mm] 1 3011E 2 3014C 1 3015E 1 1 2 3017NE 2 3017TCE 2 Wire Capacity as a through fitting. THHN, THWN 3018AE 1 3082 1 3046BE #8 AWG 18 #10 AWG 24 2 3086A 1 #12 AWG 55 3046H-2 3046KTSQ 1 2 3 #14 AWG 75 2 2 3046KD 3089E #6 AWG 13 3046QUO 1 1 2 2 3 3 GE: THQC, THHQC. Westinghouse: QuicklagC, QCH Square D, QuickGard QOB Bolt-on, 50A. Wire Capacity THHN, THWN Square D, Type QOU, 50A #6 AWG 6 #8 AWG 8 #10 AWG 10 #12 AWG 18 #14 AWG 26 The Wiremold Company 60 Woodlawn Street West Hartford, CT 06110 1-800-621-0049 • Fax 860-232-2062 ©1999 The Wiremold Company 41402R1 399