fafnir TORRIX Version 5.5 Manuel utilisateur
PDF
Télécharger
Document
Documentation technique QR code pour accéder au site de documentation technique TORRIX Version 5.5 Le capteur de niveau magnétostrictif (fr) N° de réf. 350336 Version 4 Édition 2025-01 FAFNIR GmbH • Schnackenburgallee 149 c • 22525 Hambourg • Allemagne • Tél. : +49 /40 / 39 82 07-0 • Web : www.fafnir.com Table des matières 1 Caractéristiques ........................................................................................................ 1 2 Consignes de sécurité .............................................................................................2 3 Conception et fonctionnement ............................................................................3 3.1 Versions TORRIX ..................................................................................................................................... 4 4 Montage .....................................................................................................................5 4.1 Montage avec raccord coulissant .................................................................................................... 6 4.3 Montage sur Bypass .............................................................................................................................. 7 4.2 5 Montage avec une bride ..................................................................................................................... 7 Raccordement électrique .......................................................................................9 5.1 Schémas de connexion ......................................................................................................................10 5.1.1 Schéma de connexion TORRIX ........................................................................................................10 5.1.2 Schéma de connexion TORRIX Ex ..................................................................................................10 5.2 Longueur du câble de connexion (TORRIX variantes 4 … 20 mA) .....................................11 6 Réglages ................................................................................................................... 14 5.3 Câblage ....................................................................................................................................................12 5.3.1 Presse-étoupe .......................................................................................................................................12 5.3.2 Connecteur M12 ...................................................................................................................................13 6.1 Plage de mesure du capteur de niveau .......................................................................................14 6.1.1 Réglage de la plage de mesure sur le TORRIX..........................................................................14 6.1.2 Réglage de la plage de mesure avec le PC.................................................................................16 6.2 Consommation de courant en mode erreur ..............................................................................17 6.2.1 Réglage de la consommation de courant sur le TORRIX ......................................................17 6.2.2 Réglage de la consommation de courant avec le PC .............................................................18 7 Maintenance ............................................................................................................ 19 7.1 Entretien ..................................................................................................................................................19 8 Caractéristiques techniques ............................................................................... 20 8.1 TORRIX en version 5.5 à partir du numéro d'appareil 30000 ..............................................20 7.2 I Retour .......................................................................................................................................................19 Contenu 8.2 Flotteur ....................................................................................................................................................22 9 Liste des figures ..................................................................................................... 23 10 Annexes.................................................................................................................... 24 10.1 Déclaration UE de conformité .........................................................................................................24 10.3 Manuel d'instructions .........................................................................................................................33 10.2 10.4 10.5 Attestation d’examen UE de type .................................................................................................. 25 Certificat SIL ...........................................................................................................................................40 Manuel de sécurité SIL .......................................................................................................................44 © Copyright : Reproduction et traduction uniquement avec l’autorisation écrite de FAFNIR GmbH. La FAFNIR GmbH se réserve le droit de modifier les produits sans annonce préalable. Contenu II 1 Caractéristiques Le TORRIX est un capteur de niveau de haute précision pour la mesure continue de niveau et d'interface de liquides dans des conteneurs. Le principe de mesure utilisé par le capteur exploite l’effet physique de la magnétostriction et n’est pas affecté par la température. Cette méthode est particulièrement idéale lorsque des mesures de niveau doivent être extrêmement précises, par exemple dans l’industrie chimique. Cette documentation décrit le TORRIX en version 5.5 avec une connexion par câble sur le côté de la tête de sonde (disponible à partir du numéro d'appareil 30 000). Comme connexion par câble il est possible un presse-étoupe M16 x 1,5, un connecteur M12, ou un filetage femelle M20 ou ½ pouce NPT. Une autre version est le TORRIX M12 avec un connecteur mâle M12 sur le dessus du couvercle de la tête de la sonde, voir : Documentation technique TORRIX M12, réf. 350165 Le TORRIX génère un signal de sortie 4 ... 20 mA qui est configuré à l'aide de deux boutons dans la tête de la sonde, ou un signal de sortie numérique comme protocole HART®. Les longueurs de la sonde sont possibles en version rigide de 100 mm à 6 m et en version Flex jusqu'à 22 m, ainsi que différentes plages de température et de pression. Il existe les versions suivantes : • • • • • • • TORRIX (avec raccord coulissant, pour le positionnement en continu) TORRIX Flange (soudée à la bride) TORRIX Flex (avec tube flexible de la sonde) TORRIX Bypass (pour le montage sur un Bypass avec flotteur magnétique) TORRIX 90 (avec tête de la sonde inclinée à 90°) TORRIX 6 (avec tube de la sonde de 6 mm) TORRIX 6B (avec tube de la sonde de 6 mm et passe-câble court) Pour la description de la communication avec le protocole HART®, voir : Documentation technique TORRIX Hart, anglais, réf. 207095 Pour l'installation du capteur TORRIX Flex, voir : Guide d'installation TORRIX Flex, multilingue, réf. 350118 Les capteurs TORRIX sont également disponibles en version Ex : Le capteur de niveau TORRIX Ex … avec homologation Ex (ATEX, IECEx) peut être installé dans des zones à risque d'explosion qui nécessitent un niveau de protection Ga (zone 0), Ga/Gb (zone 0/1) ou Gb (zone 1) pour le matériel électrique. Page 1/50 Caractéristiques 2 Consignes de sécurité Le TORRIX sert pour la mesure continue de niveau et d'interface de liquides dans des conteneurs. Veuillez utiliser le capteur exclusivement pour cet usage. Le fabricant décline toute responsabilité pour les dommages qui pourraient résulter d’une utilisation incorrecte ! Respectez et suivez toutes les consignes de sécurité et les instructions d'utilisation. Ce capteur de niveau a été développé, fabriqué et contrôlé selon les règles de l’art et conformément aux règles de sécurité en vigueur. Il peut cependant représenter des risques. Respecter les consignes de sécurité suivantes : • N’effectuez jamais de modifications, extensions ou transformations sur le capteur de niveau sans autorisation préalable du fabricant. • L’installation, le fonctionnement et la maintenance du capteur de niveau ne doivent être effectués que par du personnel spécialisé. Des connaissances spécialisées doivent être acquises par des formations régulières. • Les opérateurs, les installateurs et les techniciens de maintenance doivent respecter toutes les réglementations de sécurité en vigueur. Ceci est également valable quant aux prescriptions locales de sécurité et de prévention d’accidents, lesquelles ne sont pas mentionnées dans le présent mode d’emploi. Les consignes dans ce guide d'utilisation sont indiquées des symboles suivants : Le non-respect de ces consignes de sécurité entraîne un risque d’accident ou de dommage. Les consignes utiles qui garantissent la fonctionnalité des appareils et facilitant son utilisation. Règlement REACH Les capteurs du TORRIX contiennent un oxyde de plomb-titane-zirconium, qui appartient aux substances extrêmement préoccupantes (SVHC) selon le règlement (EG) n° 1907/2006 (REACH). Vous trouverez une note correspondante sur notre site Web à l’adresse : www.fafnir.com. Consignes de sécurité Page 2/50 3 Conception et fonctionnement Les capteurs de niveau se composent d’une tête de la sonde (1) et d’un tube de la sonde (4) en acier inox. Un raccord coulissant (3) (raccord vissé à bague de serrage) repose sur le tube de sonde pour un montage réglable en hauteur dans le réservoir ou une bride pour un montage fixe ou le tube de sonde est monté sur un by-pass à l'extérieur du réservoir. Un flotteur (5) se déplace sur le tube sonde ou dans le by-pass pour la mesure continue du niveau de produit et facultatif un autre flotteur (6) pour la mesure continue d’interface. ⑥ ⑤ ④ ③ ① ② ⑦ ⑩ ⑨ ⑩ ⑧ 1 – Tête de la sonde 2 – Électronique du capteur 3 – Raccord coulissant 4 – Tube de la sonde 5 – Flotteur de produit 6 – Flotteur d’interface 7 – Fil magnétostrictif 8 – Champ magnétique circulaire 9 – Aimant permanent 10 – Impulsion de torsion Figure 1 : Principe de fonctionnement de mesure magnétostrictif Le capteur de mesure fonctionne selon le principe de mesure magnétostrictif. Le tube de la sonde contient un fil tendu (7) en matériau magnétostrictif. Au moyen de l’électronique du capteur (2), des impulsions sont émises à travers le fil, lesquelles génèrent un champ magnétique circulaire (8). Comme capteur de niveau, on utilise des aimants permanents (9), qui sont intégrés à la fois dans le flotteur de produit (5) et dans le flotteur d’interface (6). Le champ magnétique des aimants de flotteur (9) magnétise le fil dans cette zone axiale. Du fait de la superposition des deux champs magnétiques, une impulsion de torsion (10) est générée au niveau de l’aimant de flotteur, et cette impulsion se déplace depuis la position du flotteur dans les deux directions à travers le fil. Une impulsion de torsion se dirige directement vers la tête de la sonde, l’autre impulsion de torsion est réfléchie à l’extrémité inférieure du tube de la sonde. Le temps s’écoulant entre l’émission de l’impulsion de courant et l’arrivée des deux impulsions de torsion au niveau de la tête de la sonde est mesuré, puis la position du flotteur est calculée. La position du flotteur d’interface est calculée grâce à la mesure d’une deuxième impulsion. Page 3/50 Conception et fonctionnement Versions TORRIX Presseétoupe ∅ 47 Tête de la sonde Tête de la sonde Raccordement à la terre Raccordement à la terre Tube d'extension 88 Raccord coulissant ∅ 47 Presseétoupe 112,5 109 ∅ 47 109 3.1 Longueur de la sonde Tube de sonde ∅ 12 Flotteur Longueur de montage Longueur de la sonde Bride Tube de sonde ∅ 12 Flotteur Bague d'arrêt Bague d'arrêt TORRIX (avec raccord coulissant) TORRIX Flange (Bride) TORRIX Bypass Figure 2 : Versions TORRIX La version TORRIX Bypass est livrée sans raccord process ni flotteur. Conception et fonctionnement Page 4/50 4 Montage Ce paragraphe décrit le montage de chaque version du capteur de niveau (voir les figures ci-après). Les réglementations nationales ainsi que les règles techniques généralement reconnues et ce manuel sont décisifs pour l'installation et la maintenance des capteurs. Toutes les réglementations locales de sécurité et de prévention des accidents qui ne figurent pas dans ce manuel doivent également être respectées. Lors du montage, éviter de tordre le tube de la sonde et de heurter le flotteur. Il est interdit de monter le capteur de niveau dans des zones soumises à un important champ magnétique externe pouvant empêcher la détermination correcte de la valeur mesurée. Il est également possible de monter le capteur de niveau par le bas du réservoir. Lorsqu'il est monté sans aide au centrage ou au guidage, la longueur maximale du capteur de niveau est de 2 mètres. Si le flotteur est retiré pendant le montage, il est impératif de l'enfiler de nouveau sur le tube de la sonde en veillant à ce que le marquage « TOP » soit orienté vers la tête du capteur afin d'assurer une mesure correcte. Page 5/50 Montage 4.1 Montage avec raccord coulissant 5 6 4 1 3 2 1 – Raccord coulissant 2 – Écrou-raccord 3 – Filetage à visser 4 – Tube de la sonde 5 – Flotteur 6 – Bague d'arrêt Figure 3 : Montage avec raccord coulissant Le démontage des flotteurs n’est nécessaire que si les flotteurs ne rentrent pas dans à l’ouverture de réservoir. Sinon, il suffit de procéder aux étapes de montage 4, 7 et le cas échéant 8. Installation du capteur de niveau dans le réservoir (voir Figure 3) : (1) Desserrez les tiges filetées de la bague d'arrêt (6) et retirez la bague d'arrêt (2) Retirer le flotteur (5) du tube sonde (4). (3) Si nécessaire, glisser le raccord coulissant (1) sur le tube de la sonde (4) Mettez le capteur de niveau en place dans le réservoir, garnissez le filetage (3) d’un matériau d’étanchéité approprié, vissez et serrez (5) Enfiler de nouveau le flotteur (5) sur le tube de la sonde (4). Pour une mesure correcte, le flotteur doit être glissé sur le tube de la sonde avec le marquage « TOP » orienté vers la tête de la sonde. (6) Remettre la bague d'arrêt (6), positionner les tiges filetées sans tête au-dessus de la rainure et les serrer (7) Positionner en hauteur le raccord process, graisser l'écrou-raccord (2) avec de pâte de montage 5 GP ou une pâte-graisse similaire pour le prémontage de bagues coupantes en inox et serrer à la main (8) Fixez l'écrou-raccord (2) avec une clé à fourche d'un tour et un quart (voir figure ci-après). Figure 4 : Serrage du raccord de compression Montage Page 6/50 4.2 Montage avec une bride En raison du risque de flexion, TORRIX Flange (bride) ne doit pas être maintenue par le tube sonde. Les vis ou les écrous et les joints sont à la charge du propriétaire et doivent être choisis en fonction du fluide. Le tube de la sonde est soudé à la bride. Par conséquent, la longueur de montage ne pourra pas être modifiée. (1) Fixer la bride et le joint avec l’aide de vis et d’écrous. (2) Si le flotteur est trop encombrant par rapport à l’ouverture de montage, voir chapitre « Montage avec raccord coulissant ». 4.3 Montage sur Bypass Le capteur de niveau est monté à l'extérieur du tube du Bypass (voir figure ci-après) à l'aide d'un matériel de fixation approprié (non magnétique). Afin d'assurer une mesure fiable, il est impératif de monter le tube de la sonde sans contraintes et sans déformations externes. La distance entre le tube de la sonde et le tube de Bypass doit être la plus petite possible. Seuls les flotteurs validés par FAFNIR peuvent être utilisés. Page 7/50 Montage TORRIX Bypass TORRIX Bypass 50 min. Distance entre le tube de la sonde Abstand et l'axe duSondenrohr flotteur : la zu distance Schwimmermitte: max. maxi dépend du flotteur Abstand de Bypass abhängig vom Bypass-Schwimmer Position max. max. de l'aimant Magnetposition Flotteur de Bypass Bypass-Schwimmer Bypassrohr Tube de Bypass Position de l'aimant Magnetposition Fixation de la sonde Sondenbefestigung (unmagnetisch) (non magnétique) Position min. min. de l'aimant Magnetposition A A 70 min. Abstandshalter Entretoise Longueur de la sonde Sondenlänge Plage de mesure Messbereich Sondenrohr spannungsfrei Tube de sonde sans contraintes (unverformt) montiert monté (sans déformation) SCHNITT A-A Section A-A Figure 5 : Montage avec by-pass Montage Page 8/50 5 Raccordement électrique Le raccordement électrique s'effectue sur le côté de la tête de la sonde par un presseétoupe M16 x 1,5, un connecteur mâle M12 ou un filetage femelle M20 ou ½ pouce NPT. La mise à la terre capteur ou la compensation de potentiel peut être effectuée par la connexion à la terre sur la tête de la sonde. La mise à la terre ou la compensation de potentiel doit être réalisée par l’installateur conformément aux règles d’installation nationales en vigueur. Protégez la tête du capteur contre la pénétration d'eau ! L'étanchéité des filetages doit être garanti. Veillez à ce que les presse-étoupes et le couvercle de la tête de capteur soient bien serrés. Pour les versions TORRIX Ex…, les données techniques du certificat d'examen UE de type et les instructions d'utilisation doivent être respectées (voir annexe). Dans la version à sécurité intrinsèque, le capteur de niveau TORRIX Ex ne peut être exclusivement connecté dans un environnement potentiellement explosif à des équipements associés certifiés par un organisme de contrôle agréé. Si le capteur de niveau est utilisé dans un environnement potentiellement explosif, la capacité externe admissible (Co ) et l'inductance (Lo ) de l'équipement associé ne doivent pas être dépassées, voir les données électriques de l'équipement. Le câble de raccordement à l’équipement correspondant doit être marqué dans le cas d’une utilisation en zone Ex, de préférence par un câble bleu pour des circuits électriques à sécurité intrinsèque. Page 9/50 Raccordement électrique 5.1 5.1.1 Schémas de connexion Schéma de connexion TORRIX Le capteur de niveau de remplissage sans homologation Ex doit être installé selon le schéma de connexion suivant : Spannungsquelle Source de tension UU = 50 30 VDC V max max= + Y + TORRIX 8min … 50 VDC U Umin ==8 8V VDC _ 4 … 20 mA I R1 R3 Charge Bürde R2 Leitungswiderstände Résistances de ligne U Figure 6 : Schéma de connexion TORRIX Source de tension : Umax = 50 VDC Tension minimale d’alimentation : Umin = 8 VDC Consommation de courant maximal : Imax = 21,5 mA 5.1.2 Schéma de connexion TORRIX Ex En atmosphère explosible, le capteur de niveau de remplissage avec homologation Ex doit être installé selon le schéma de connexion suivant : Amplificateur d’isolement (exemple) (Beispiel) Trennverstärker (Version Ex) TORRIX (Ex-Ausführung) Y + I - 88...30 … 30 VVDC 44...20 … 20 mA mA R1 R2 + - 4...20 mA Leitungswiderstände Résistances de ligne Figure 7 : Schéma de connexion TORRIX Ex Hilfsenergie Énergie auxiliaire Source de tension : Umax = 30 VDC Tension minimale d’alimentation : Umin = 8 VDC Consommation de courant maximal : Imax = 21,5 mA Raccordement électrique Page 10/50 5.2 Longueur du câble de connexion (TORRIX variantes 4 … 20 mA) Le câble (longueur et section transversale) doit être choisi de telle sorte que la tension d'alimentation minimale spécifique de la sonde (Umin) au du capteur de niveau soit atteinte même capteur de niveau dans le cas de la consommation de courant la plus élevée (Imax), voir chapitre « Schémas de connexion ». La résistance maximale (tension d'alimentation ÷ consommation de courant maximal) résumée par la résistance du câble et la résistance de charge des appareils connectés ne doit pas être dépassée. La longueur maximale de câble se calcule comme suit : L = Longueur de câble [m] U = Tension d'alimentation [VDC] moins la valeur de tolérance (par exemple ±5 %) Umin = Tension minimale d’alimentation [VDC] Imax = Consommation de courant maximal [A] RB = Résistance maximale de charge RA = Résistance du câble par mètre [Ω/m] pour la section de câble A [mm²] Longueur de câble L L = (((U – Umin) / Imax) – RB) / RA Le tableau suivant indique la résistance de câble RA par m de câble en cuivre de différentes sections : Section de câble A [mm²] Résistance RA du câble en cuivre par mètre [Ω/m] 0,5 0,0356 1,0 0,0178 Exemple de calcul pour déterminer la longueur de câble : Tension d'alimentation U = 12 VDC – 5 % = 11,4 VDC Tension minimale d’alimentation Umin = 8 VDC Consommation de courant maximal Imax = 21,5 mA Résistance maximale de charge RB = 86,8 Ω Résistance du câble par mètre RA = 0,0356 Ω/m pour la section de câble A = 0,5 mm² L = (((11,4 – 8) / 0,0215) - 86,8) / 0,0356 = 2000 m Un câble à 2 conducteurs peut théoriquement mesurer jusqu'à 1000 m de long avec les paramètres de cet exemple. Page 11/50 Raccordement électrique 5.3 Câblage Le câblage des capteurs ne doit être effectué que hors tension. 5.3.1 Presse-étoupe À l'intérieur de la tête de la sonde du capteur de niveau, cachée par le couvercle, se trouvent les bornes de raccordement protégées et boutons de configuration. Pour le câblage du capteur de niveau, procédez de la manière suivante : (1) Dévisser le couvercle de la tête du capteur (1) à l'aide d'une clé plate. (2) Desserrer l'écrou-raccord (2) du presse-étoupe (3). 1 3 5 2 4 Figure 8 : Câblage (3) (4) (5) (6) Enfiler le câble à 2 fils (4) dans l'écrou-raccord (2) et revisser l'écrou-raccord. Le câble doit avoir un diamètre extérieur de 4 … 8 mm. Retirer la bornier (5). Connecter le câble à 2 fils (4) aux bornes repérées (+) et (–) à la bornier (5). Branchez la bornier (5) de retour sur. Utilisez uniquement les deux broches du milieu comme emplacement (flèches rouges sur la Fig. 9). Le câble doit avoir aucune traction ! 5 5 Image 9 : Bornier amovible (7) (8) Si nécessaire, régler les points de référence (voir point 6.1). Revisser le couvercle de la tête du capteur (1). Raccordement électrique Page 12/50 5.3.2 Connecteur M12 • S'il n'est pas encore raccordé, branchez le connecteur femelle M12 du câble de raccordement FAFNIR fourni au connecteur M12 de la tête de capteur. Tournez l’écrou-raccord du connecteur femelle M12 d’abord à la main, puis bloquez l’écrou à l’aide d’une clé par une rotation de 180°. Le couple de serrage devrait se situer entre 100 et 150 Ncm. • Connectez le câble provenant de l’unité d’analyse avec le câble de raccordement FAFNIR, p. ex. en utilisant un manchon d'installation, selon l’affectation suivante : Signal Tension + Utilisé en interne Tension Utilisé en interne – Codage de couleurs du câble FAFNIR Affectation du connecteur femelle M12 brun Broche 1 blanc Broche 2 bleu Broche 3 noir Broche 4 Broche 3 Broche 4 Broche 2 Broche 1 Affectation des bornes du connecteur femelle M12 du câble de raccordement FAFNIR Le câble de raccordement entre TORRIX … et l’équipement associé doit présenter les caractéristiques suivantes : • 2 fils, câble non blindé • Pour les applications Ex, couleur bleue ou marquage bleu (câble pour circuits à sécurité intrinsèque) Page 13/50 Raccordement électrique 6 Réglages Les réglages décrits ci-dessous peuvent également être effectués facilement à distance pour les versions avec protocole HART® sans qu'il soit nécessaire d'ouvrir la tête de la sonde. 6.1 6.1.1 Plage de mesure du capteur de niveau Réglage de la plage de mesure sur le TORRIX Un bouton vert (2) et un bouton rouge (3) et une diode électroluminescente (LED) verte dans la zone de connexion de la tête de la sonde servent à ajuster les points de mesure 4 mA et 20 mA du capteur de niveau. L'étendue de mesures du capteur de niveau est réglée au maximum par défaut, c'est-à-dire à 4 mA au pied de la sonde et à 20 mA à la tête de la sonde (longueur de sonde moins 100 mm). L'étendue de mesure est configurable pour l'adaptation au réservoir concernés. Toutefois, un espace libre minimum de 10 mm doit être respecté. Si la distance est inférieure à cette distance minimale, le sens d'affichage du capteur de niveau sera automatiquement inversé (mesure du niveau à vide). Grâce au réglage, il est également possible d'inverser l'affichage de la valeur mesurée : il est par exemple possible de régler l'étendue de la plage de mesures du capteur de niveau au maximum avec 4 mA à la tête du capteur et 20 mA au pied de la sonde. 4 1 2 3 1. Couvercle de la tête de sonde 2. Bouton 4 mA (vert) 3. Bouton 20 mA (rouge) 4. LED Cal / Err (verte) Figure 10 : Zone de connexion de la tête de sonde (1) Dévisser le couvercle de la tête du capteur (1) à l'aide d'une clé plate. (2) Maintenez le bouton vert (2) ou le bouton rouge (3) enfoncé pendant au moins 3 secondes. La LED verte (4) commence à clignoter. (3) Le capteur de niveau est désormais en mode réglage. La consommation de courant du capteur de niveau s'élève à 12 mA. Sans nouvel actionnement d'une touche, le capteur de niveau restera en mode de réglage pendant 20 secondes. Il retourne ensuite au mode mesure sans modification du réglage. En mode de réglage, il est Réglages Page 14/50 maintenant possible de modifier les points de référence 4 mA et 20 mA dans n'importe quel ordre. (4) Détermination d'un point de référence : − Déplacer le flotteur au point de référence souhaité − appuyer brièvement (0,1 … 2 secondes) sur le bouton vert (2) afin de définir une consommation de courant de 4 mA dans cette position. − appuyer brièvement (0,1 … 2 secondes) sur le bouton rouge (3) afin de définir une consommation de courant de 20 mA dans cette position. Après avoir appuyé sur le bouton vert, la LED reste éteinte pendant 5 secondes. Après avoir appuyé sur le bouton rouge, la LED reste allumée en continu pendant 5 secondes. Le capteur restera ensuite en mode de réglage pendant encore 15 secondes. La modification sera ensuite enregistrée automatiquement et il retournera au mode de mesure. Le réglage n'est mémorisé que lorsque le capteur de niveau passe automatiquement du mode réglage au mode mesure et que la LED s'éteint. Le réglage restera en mémoire, même si le capteur de niveau est mis hors tension par la suite. Pour le réglage « à vide » dans le cas de capteurs Bypass, il est nécessaire de disposer d'un système magnétique avec douille d'écartement fourni par le fabricant du Bypass. Il est également possible de procéder au réglage lorsque le capteur est démonté. Page 15/50 Réglages 6.1.2 Réglage de la plage de mesure avec le PC Le TORRIX peut être ajusté avec l'outil de configuration TORRIX sur le PC, voir documentation technique : TORRIX Configuration Tool, anglais, réf. 350258 La configuration avec le PC ne doit être effectuée qu'en dehors de la zone potentiellement explosive. Pour connecter le TORRIX au PC, l'adaptateur USB FAFNIR [TORRIX] et l'adaptateur M12 sont nécessaires (réf. 900223) : (1) Dévisser le couvercle de la tête de sonde (1) à l'aide d'une clé plate. (2) Fixez l'adaptateur M12 à la borne 4 voies du TORRIX (3) Connectez le connecteur M12 de l'adaptateur à l'adaptateur USB FAFNIR (4) Connectez l'adaptateur USB FAFNIR au PC Figure 11 : Connexion adaptateur M12 Pour plus d'informations, voir la documentation technique : FAFNIR USB-Adapter, anglais, réf. 350000 Aucun adaptateur M12 n'est requis pour le TORRIX avec raccord à vis M12. L'adaptateur USB FAFNIR se branche directement sur le connecteur M12. Réglages Page 16/50 6.2 Consommation de courant en mode erreur 6.2.1 Réglage de la consommation de courant sur le TORRIX Si un dysfonctionnement empêche le capteur de niveau d'enregistrer une position du flotteur plausible, c'est-à-dire si le niveau mesuré est incorrect, le capteur passe en mode erreur après un court laps de temps. La signalisation du mode erreur correspond à NAMUR NE43. Elle est réglée à 21,5 mA par défaut, mais peut également être réglée à 3,6 mA. Ajustage de la consommation de courant en mode erreur (voir Figure 10). (1) Dévisser le couvercle de la tête du capteur (1) à l'aide d'une clé plate. (2) Appuyer simultanément sur les deux touches « 4 mA » (2) et « 20 mA » (3) pendant au moins 3 secondes. La LED verte (4) « Cal/Err » clignote rapidement. La consommation de courant du capteur de niveau s'élève à 16 mA. La LED ne clignote plus au bout de 5 secondes. Elle affiche la consommation de courant d’erreur réglé pendant 2,5 secondes. Si la LED est allumée en permanence, IErreur = 21,5 mA, si la LED s’éteint, IErreur = 3,6 mA. Sans nouvel actionnement d'une touche, le capteur de niveau restera en mode erreur pendant encore 2,5 secondes. Il retourne ensuite au mode mesure sans modification de réglage. (3) Pour le réglage de la consommation de courant − de 3,6 mA pendant le temps de séjour (10 sec.) en mode erreur, appuyer brièvement (0,1 … 2 secondes) sur la touche « 4 mA » (2). − de 21,5 mA pendant le temps de séjour (10 sec.) en mode erreur, appuyer brièvement (0,1 … 2 secondes) sur la touche « 20 mA » (3). Le réglage n'est mémorisé que lorsque le capteur de niveau passe automatiquement du mode réglage au mode mesure et que la LED s'éteint. Le réglage restera en mémoire, même si le capteur de niveau est mis hors tension par la suite. (4) Revisser le couvercle de la tête du capteur (1). Si le capteur de niveau détecte pendant le fonctionnement qu'il n'est pas possible d'indiquer un niveau correct de remplissage à cause d'une tension d'alimentation trop faible, il bascule en mode erreur (indépendamment des réglages effectués relatifs au courant d'erreur) et règle la consommation de courant à 3,6 mA. Page 17/50 Réglages 6.2.2 Réglage de la consommation de courant avec le PC La consommation de courant en mode erreur peut être ajustée à l'aide de l'outil TORRIX Configuration Tool sur le PC, voir la documentation technique : TORRIX Configuration Tool, anglais, réf. 350258 La configuration avec le PC ne doit être effectuée qu'en dehors de la zone potentiellement explosive. (1) Connectez le TORRIX au PC et démarrez le TORRIX Configuration Tool (2) Dans le champ de sélection « COM Port », sélectionnez l'interface de port COM affectée. (3) Dans le champ de sélection « Alarm Current », sélectionnez la consommation de courant en cas d'erreur. Figure 12 : TORRIX Configuration Tool (4) Réglages Confirmez et enregistrez le réglage en cliquant sur le bouton « Write ». Page 18/50 7 Maintenance 7.1 Entretien Le capteur de niveau n’exige aucun entretien. 7.2 Retour Avant de renvoyer des produits FAFNIR, une validation (RMA) par le S.A.V. de FAFNIR est requise. Adressez-vous à votre conseiller client ou au S.A.V. qui vous informera sur les détails du retour. Le retour de produits FAFNIR est uniquement possible après validation par le S.A.V. de FAFNIR. Page 19/50 Maintenance 8 Caractéristiques techniques D'autres données techniques figurent également dans l'attestation d'examen UE de type et dans les instructions d'utilisation en annexe de ce manuel. 8.1 TORRIX en version 5.5 à partir du numéro d'appareil 30000 Raccordement électrique Connexion 2 fils 3,8 … 20,5 mA consommation de courant pour la sortie de mesures 3,6 mA ou 21,5 mA consommation de courant en cas d'erreur Tension d'alimentation TORRIX TORRIX EX 8 … 50 VDC 8 … 30 VDC Indice de protection : IP68 (conditions d'essai IPX8 : profondeur d’immersion 2 mètres pendant 30 jours) Raccord process Raccord coulissant pour un réglage en hauteur en continu Standard G ½ (raccord à compression) Bride sur demande Matériau voir tube de la sonde Montage du Bypass Tête de la sonde Hauteur 109 mm, version Bypass 112,5 mm Matériau Inox 1.4305 (303) Diamètre de câble 4 … 8 mm Température –40 … +85 °C Tube de la sonde Longueur 200 … 6000 mm (selon commande) Longueur TORRIX Flex 1.5 m ... 22 m Diamètre 12 mm, (autres diamètres sur demande) Matériau Inox 1.4571 (316Ti) (Hastelloy, ou autres matières sur demande) Plage de mesure librement réglable (> 10 mm) Température standard -40 °C … +85 °C Température normale (NT) -40 °C … +125 °C Température haute (HT) -40 °C … +250 °C Température très haute (HHT) -40 °C … +450 °C Température basse (LT) -65 °C … +125 °C Communication Protocole HART® (disponible) Caractéristiques techniques Page 20/50 Précision de mesure Composant numérique NT/LT Précision de mesure Composant numérique HT/HHT Précision de mesure Composant numérique Bypass Linéarité supérieure à ±0,2 mm ou ±0,01 %, supérieure à ±0,001 % par K Précision de répétabilité supérieure à 0,05 mm Résolution supérieure à 10 µm Linéarité supérieure à ±0,5 mm ou ±0,025 %, supérieure à ±0,01 % par K Précision de répétabilité supérieure à 0,1 mm Résolution supérieure à 50 µm Linéarité supérieure à ±0,5 mm ou ±0,025 %, supérieure à ±0,001 % par K Précision de répétabilité supérieure à 0,05 mm Résolution supérieure à 10 µm Précision de mesure Composant numérique Bypass HT/HHT Linéarité supérieure à ±2 mm ou ±0,1 %, supérieure à ±0,01 % par K Précision de répétabilité supérieure à 0,5 mm Résolution supérieure à 50 µm Précision de mesure Composant analogique Linéarité supérieure à ±0,01 % Coefficient de température supérieur à 0,01% par K Résolution supérieure à 0,5 µA (16 bit) Page 21/50 Caractéristiques techniques 8.2 Flotteur Le flotteur est un composant essentiel du capteur de niveau. Il doit être adapté au fluide en termes de densité, de résistance à la pression et de résistance du matériau. Les flotteurs mentionnés ci-après sont remplaçables. Ils peuvent être commandés à l’unité. D’autres modèles et matériaux de flotteurs sont disponibles sur demande. La densité et la position de l’aimant peuvent varier entre les flotteurs du même type. Un nouveau réglage peut être nécessaire. Tous les flotteurs peuvent également être utilisés à une pression de -1 bar (vide). Extrait de la gamme de flotteurs disponibles : Densité min. du liquide [g/cm³] Matériau Pression max. de fonctionnement [bar] à 20 °C *) Forme [mm] 0,5 0,6 0,7 0,7 0,7 0,85 0,95 Titane 1.4571 (316Ti) 1.4571 (316Ti) C276 1.4571 (316Ti) 1.4571 (316Ti) 1.4571 (316Ti) 20 20 16 10 40 20 50 Sphère ø 50 Sphère ø 52 Cylindre ø 53 Cylindre ø 46 Sphère ø 52 Sphère ø 43 Sphère ø 43 *) La pression maximale de fonctionnement diminue à partir de 50 °C La résistance à la pression ne pourra être garantie que pour des flotteurs non endommagés. Il suffit de petites bosselures non visibles, par exemple à la suite d’une chute du flotteur de la table sur un sol en pierre, pour réduire de manière significative la résistance à la pression. Caractéristiques techniques Page 22/50 9 Liste des figures Figure 1 : Principe de fonctionnement de mesure magnétostrictif.................................................. 3 Figure 2 : Versions TORRIX .............................................................................................................................. 4 Figure 3 : Montage avec raccord coulissant.............................................................................................. 6 Figure 4 : Serrage du raccord de compression ........................................................................................ 6 Figure 5 : Montage avec by-pass .................................................................................................................. 8 Figure 6 : Schéma de connexion TORRIX ................................................................................................ 10 Figure 7 : Schéma de connexion TORRIX Ex .......................................................................................... 10 Figure 8 : Câblage ............................................................................................................................................ 12 Image 9 : Bornier amovible .......................................................................................................................... 12 Figure 10 : Zone de connexion de la tête de sonde............................................................................ 14 Figure 11 : Connexion adaptateur M12 ................................................................................................... 16 Figure 12 : TORRIX Configuration Tool ................................................................................................... 18 Page 23/50 Liste des figures EU-Konformitätserklärung EU Declaration of Conformity Declaration UE de Conformite Dichiarazione di Conformitä UE FAFNIR FAFNIR GmbH, Deutschland / Germany / Allemagne / Germania erklärt als Hersteller in alleiniger Verantwortung, dass die Produkte declares as manufacturer under sole responsibility that the products declare sous sa seule responsabilite en qualite de fabricant que les produits dichiara sotto la sola responsabilitä del produttore, che i prodotti sono Füllstandsensoren / Filling Level Sensors / Capteurs de Niveau / Sensori di livello TORRIX .../VISY-Stick ... den Vorschriften der europäischen Richtlinien comply with the regulations of the European directives sont conformes aux reglementations des directives europeennes suivantes rispetta i regolamenti delle direttive europee 2011/65/EU 2011/65/EU 2011/65/UE 2011/65/UE 2014/30/EU 2014/30/EU 2014/30/UE 2014/30/UE 2014/34/EU 2014/34/EU 2014/34/UE 2014/34/UE Beschränkung der Verwendung bestimmter gefährlicher Stoffe in Elektro- und Elektronikgeräten Restriction of the use of certain hazardous substances in electrical and electronic equipment Limitation de l'utilisation de certaines substances dangereuses dans les equipements electriques et electroniques Restrizione deM'uso di determinate sostanze pericolose nelle apparecchiature elettriche ed elettroniche Elektromagnetische Verträglichkeit Electromagnetic compatibility Compatibilite electromagnetique Compatibilitä elettromagnetica Geräte und Schutzsysteme zur bestimmungsgemäßen Verwendung in explosionsgefährdeten Bereichen Equipment and protective Systems intended for use in potentially explosive atmospheres Appareils et systemes de protection destines ä etre utilises en atmospheres explosibles Apparecchi e sistemi di protezione destinati a essere utilizzati in atmosfera potenzialmente esplosiva RoHS RoHS RoHS RoHS EMV EMC CEM CEM ATEX ATEX ATEX ATEX durch die Anwendung folgender harmonisierter Normen entsprechen by applying the harmonised Standards par l'application des normes applicando le norme armonizzate RoHS / RoHS / RoHS / RoHS EMV / EMC / CEM / CEM ATEX / ATEX / ATEX / ATEX EN IEC 63000:2018 EN 61326-1:2013 EN IEC 60079-0:2018 EN 60079-26:2015 EN 60079-1:2014 EN 60079-31:2014 EN 60079-11:2012 Die Produkte sind bestimmt als Elektro- und Elektronikgeräte der RoHSThe products are determined as electrical and electronic equipment of RoHS Les produits sont determines comme des equipements electriques et electroniques de RoHS I prodotti sono determinati come apparecchiature elettriche ed elettroniche della RoHS Kategorie / Category / Categorie / Categoria Überwachungs- und Kontrollinstrumenten in der Industrie / Industrial Monitoring and Control Instruments / Instruments de contröle et de surveillance industriels / Strumenti di monitoraggio e controllo industriali Die Produkte entsprechen den EMV-Anforderungen The products comply with the EMC requirements Les produits sont conformes aux exigences CEM I prodotti sono conformi ai requisiti CEM Störaussendung / Emission / Emission / L'emissione Störfestigkeit / Immunity / D'immunite / Immunitä Klasse B / Class B / Classe B / Classe B Industrielle elektromagnetische Umgebung / Industrial electromagnetic environment/ Environnement electromagnetique Industrie! / Ambiente elettromagnetico industriale Die notifizierte Stelle TÜV NORD CERT GmbH, 0044 hat eine EU-Baumusterprüfung durchgeführt und folgende Bescheinigung ausgestellt The notified body TÜV NORD CERT GmbH, 0044 performed a EU-type examination and issued the certificate L'organisme notifie TÜV NORD CERT GmbH, 0044 a effectue examen UE de type et a etabli l'attestation L'organismo notificato TÜV NORD CERT GmbH, 0044 ha effettuato esame UE del tipo e rilasciato il certificato TORRIX Ex ... / VISY-Stick ... _________ Hamburg. 2023-04-14_________ Ort, Datum / Place, Date / Lieu, Date / Luogo, data Geschäftsführer / Managing Director/ Gerant / Direttore Generale: Rene Albrecht Seite / Page / Page / Pagina 1/1 FAFNIR GmbH • Schnackenburgallee 149c 22525 Hamburg . Tel.:+49 / (0)40 / 39 82 07-0 www.fafnir.de [email protected] Translation (1) EU-Type Examination Certificate (2) Equipment and protective systems intended for use in potentially explosive atmospheres, Directive 2014/34/EU (3) Certificate Number TÜV 99 ATEX 1496 X (4) for the product: Filling level sensors type VISY-Stick … and type TORRIX Ex… (5) of the manufacturer: FAFNIR GmbH (6) Address: Issue: 03 22525 Hamburg Germany Order number: Date of issue: 8003035365 See date of signature (7) The design of this product and any acceptable variation thereto are specified in the schedule to this EU-Type Examination Certificate and the documents therein referred to. (8) The TÜV NORD CERT GmbH, Notified Body No. 0044, in accordance with Article 17 of the Directive 2014/34/EU of the European Parliament and the Council of 26 February 2014, certifies that this product has been found to comply with the Essential Health and Safety Requirements relating to the design and construction of products intended for use in potentially explosive atmospheres given in Annex II to the Directive. The examination and test results are recorded in the confidential ATEX Assessment Report No. 22 203 302211. (9) Compliance with the Essential Health and Safety Requirements has been assured by compliance with: EN IEC 60079-0:2018/AC:2020-02 EN 60079-1:2014/AC:2018-09 EN 60079-11:2012 EN 60079-26:2015 EN 60079-31:2014 except in respect of those requirements listed at item 18 of the schedule. (10) If the sign ”X” is placed after the certificate number, it indicates that the product is subject to the Specific Conditions for Use specified in the schedule to this certificate. (11) This EU-Type Examination Certificate relates only to the design, and construction of the specified product. Further requirements of the Directive apply to the manufacturing process and supply of this equipment. These are not covered by this certificate. (12) The marking of the product shall include the following: See „Type code and Marking“ TÜV NORD CERT GmbH, Am TÜV 1, 45307 Essen, notified by the central office of the countries for safety engineering (ZLS), Ident. Nr. 0044, legal successor of the TÜV NORD CERT GmbH & Co. KG Ident. Nr. 0032 The deputy of the head of the notified body Hanover office, Am TÜV 1, 30519 Hannover, Tel. +49 511 998-61455, Fax +49 511 998-61590 This certificate may only be reproduced without any change, schedule included. Excerpts or changes shall be allowed by the TÜV NORD CERT GmbH P17-F-011 Rev. 02/11.21 Page 1/8 (13) SCHEDULE (14) EU-Type Examination Certificate No. TÜV 99 ATEX 1496 X Issue 03 (15) Description of product: The filling level sensors type VISY-Stick … and type TORRIX Ex… are used for continuous measurement of liquid levels within potentially explosive areas. Floaters are used to detect the fluid levels. These slide on a sensor tube. For interface or water detection, a second float can be mounted on the sensor tube. In addition, the density of the liquid can be determined by means of a density module. The temperature measuring chain VISY-Stick ... Temp ... is used to measure temperatures at different heights and does not use any floats. Type code and Marking: Type VISY-Stick … (Ex-relevant designations only): VISY-Stick Sump … Environmental sensor (Leakage control) VISY-Stick Advanced … Advanced precision of measurement and temperature sensors VISY-Stick Flex … Flexible sensor tube VISY-Stick … Serial communication VISY-Stick … RS485 RS-485 interface VISY-Stick … Temp … Temperature measuring chain VISY-Stick … TLS TLS interface Type TORRIX Ex… (Ex-relevant designations only): TORRIX Ex… 4…20 mA interface (with configuration buttons) optionally with HART protocol TORRIX Ex C… 4…20 mA interface (without configuration buttons) optionally with HART protocol TORRIX Ex RS485… RS-485 interface TORRIX Ex SC… Serial communication TORRIX Ex TAG… TAG interface (communication in accordance with EN 14116) TORRIX Ex XT… RS-485- or 4…20 mA interface optionally with display (Ex i) TORRIX Exd XT… RS-485- or 4…20 mA interface optionally with display (Ex d+t+i) TORRIX Ex…-A Advanced precision of measurement and temperature sensors TORRIX Ex… Flex Flexible sensor tube TORRIX Ex… PL With plastic coating against very aggressive media This certificate may only be reproduced without any change, schedule included. Excerpts or changes shall be allowed by the TÜV NORD CERT GmbH P17-F-011 Rev. 02/11.21 Page 2/8 Schedule to EU-Type Examination Certificate No. TÜV 99 ATEX 1496 X Issue 03 • • • • • • • • • • VISY-Stick … VISY-Stick (Flex) Temp VISY-Stick … RS485 VISY-Stick (Flex) Temp RS485 TORRIX Ex… TORRIX Ex C… TORRIX Ex RS485… TORRIX Ex SC… TORRIX Ex TAG… TORRIX Ex XT… II 1 G II 1/2 G II 2 G II 2 D Ex ia IIC T6…T1 Ga Ex ia IIC T6…T1 Ga/Gb Ex ia IIC T6…T1 Gb Ex ia IIIC TX°C Db (see thermal data) • • • • • • • • • • • • • • • • • • • • • • VISY-Stick Advanced … VISY-Stick … Flex … VISY-Stick … Advanced RS485 VISY-Stick … Flex RS485 TORRIX Ex …-A TORRIX Ex … Flex TORRIX Ex … PL TORRIX Ex C…-A TORRIX Ex C… Flex TORRIX Ex C… PL TORRIX Ex RS485…-A TORRIX Ex RS485… Flex TORRIX Ex RS485… PL TORRIX Ex SC…-A TORRIX Ex SC… Flex TORRIX Ex SC… PL TORRIX Ex TAG…-A TORRIX Ex TAG… Flex TORRIX Ex TAG… PL TORRIX Ex XT…-A TORRIX Ex XT… Flex TORRIX Ex XT… PL II 1 G II 1/2 G II 2 G II 2 D Ex ia IIB T6…T1 Ga Ex ia IIB T6…T1 Ga/Gb Ex ia IIB T6…T1 Gb Ex ia IIIC TX°C Db (see thermal data) • • VISY-Stick … TLS VISY-Stick (Flex) Temp TLS II 1 G II 1/2 G II 2 G II 2 D Ex ia IIC T4…T1 Ga Ex ia IIC T4…T1 Ga/Gb Ex ia IIC T4…T1 Gb Ex ia IIIC TX°C Db (see thermal data) • • VISY-Stick … Advanced TLS VISY-Stick … Flex TLS II 1 G II 1/2 G II 2 G II 2 D Ex ia IIB T4…T1 Ga Ex ia IIB T4…T1 Ga/Gb Ex ia IIB T4…T1 Gb Ex ia IIIC TX°C Db (see thermal data) • TORRIX Exd XT… • • • TORRIX Exd …-A TORRIX Exd … Flex TORRIX Exd … PL II 1/2 G Ex ia/db IIC T6…T1 Ga/Gb II 2 G Ex db ia IIC T6…T1 Gb II 2 D Ex ia tb IIIC TX°C Db (see thermal data) II 1/2 G Ex ia/db IIB T6…T1 Ga/Gb II 2 G Ex db ia IIB T6…T1 Gb II 2 D Ex ia tb IIIC TX°C Db (see thermal data) This certificate may only be reproduced without any change, schedule included. Excerpts or changes shall be allowed by the TÜV NORD CERT GmbH P17-F-011 Rev. 02/11.21 Page 3/8 Schedule to EU-Type Examination Certificate No. TÜV 99 ATEX 1496 X Issue 03 Electrical data: VISY-Stick …; VISY-Stick (Flex) Temp; TORRIX Ex SC…; VISY-Stick Advanced …; VISY-Stick … Flex …; TORRIX Ex SC…-A; TORRIX Ex SC… Flex and TORRIX Ex SC… PL: Signal and power supply In type of protection intrinsic safety Ex ia IIC/IIB/IIIC (Terminals +, -, A, B) or (M12-Plug) Only for connection to certified intrinsically safe circuits. Maximum values: Ui = 15 V Ii = 60 mA Pi = 100 mW Effective internal capacitance Ci = 10 nF Effective internal inductance Li = 100 µH VISY-Stick … RS485; VISY-Stick (Flex) Temp RS485; TORRIX Ex…; TORRIX Ex C…; TORRIX Ex RS485…; TORRIX Ex TAG…; TORRIX Ex XT…; VISY-Stick … Advanced RS485; VISY-Stick … Flex RS485; TORRIX Ex …-A; TORRIX Ex … Flex; TORRIX Ex … PL; TORRIX Ex C…-A; TORRIX Ex C… Flex; TORRIX Ex C… PL; TORRIX Ex RS485…-A; TORRIX Ex RS485… Flex; TORRIX Ex RS485… PL; TORRIX Ex TAG…-A; TORRIX Ex TAG… Flex; TORRIX Ex TAG… PL; TORRIX Ex XT…-A; TORRIX Ex XT… Flex and TORRIX Ex XT… PL: Signal and power supply In type of protection intrinsic safety Ex ia IIC/IIB/IIIC (Terminals +, -, A, B resp. +, -) or Only for connection to certified intrinsically safe (M12-Plug) circuits. Maximum values: Ui = 30 V Ii = 200 mA at Ta ≤ +70 °C Ii = 100 mA at Ta ≤ +85 °C Pi = 1 W Effective internal capacitance Ci = 10 nF Effective internal inductance Li = 20 µH VISY-Stick … TLS; VISY-Stick (Flex) Temp TLS; VISY-Stick … Advanced TLS and VISY-Stick … Flex TLS: Signal and power supply In type of protection intrinsic safety Ex ia IIC/IIB/IIIC (Terminals +, -) or (M12-Plug) Only for connection to certified intrinsically safe circuits. Maximum values: Ui = 13 V Ii = 200 mA Pi = 625 mW Effective internal capacitance Ci = 20 nF Effective internal inductance Li = 410 µH This certificate may only be reproduced without any change, schedule included. Excerpts or changes shall be allowed by the TÜV NORD CERT GmbH P17-F-011 Rev. 02/11.21 Page 4/8 Schedule to EU-Type Examination Certificate No. TÜV 99 ATEX 1496 X Issue 03 TORRIX Exd XT…; TORRIX Exd …-A; TORRIX Exd … Flex and TORRIX Exd … PL: Signal and power supply For connection to non-intrinsically safe circuits with (Terminals +, -, A, B) the following values: U = 12 Vd.c. … 50 Vd.c.; I = 4 mA … 20 mA Um = 253 V For connection to non-intrinsically safe circuits with the following values: Heating circuit (Terminals -, +) U = 24 Vd.c. ± 10 % I = 160 mA Thermal data: VISY-Stick …; VISY-Stick (Flex) Temp; TORRIX Ex SC…; VISY-Stick Advanced …; VISY-Stick … Flex …; TORRIX Ex SC…-A; TORRIX Ex SC… Flex and TORRIX Ex SC… PL: For EPL Ga or EPL Ga/Gb or EPL Gb, the permissible temperature range depending on the variant and the temperature class can be taken from the following table: Temperature class T6 T5 T4 T3 T2 T1 Ambient temperature range -40 °C … +50 °C -40 °C … +65 °C -40 °C … +85 °C -40 °C … +85 °C -40 °C … +85 °C -40 °C … +85 °C Medium temperature range -40 °C … +75 °C -40 °C … +90 °C -40 °C … +125 °C -40 °C … +190 °C -40 °C … +285 °C -40 °C … +435 °C For EPL Db applications, the permissible ambient temperature range depending on the permissible surface temperature can be taken from the following table: Maximum surface temperature Dust layer ≤ 5 mm With total immersion T5 X°C T X°C X°C = Ta + 30 °C X°C = 135 °C Ambient temperature range Ta -40 °C … +85 °C The equipment is suitable for dusts with an ignition temperature of more than 190 °C under a dust layer of 5 mm (glow temperature). This certificate may only be reproduced without any change, schedule included. Excerpts or changes shall be allowed by the TÜV NORD CERT GmbH P17-F-011 Rev. 02/11.21 Page 5/8 Schedule to EU-Type Examination Certificate No. TÜV 99 ATEX 1496 X Issue 03 VISY-Stick … RS485; VISY-Stick (Flex) Temp RS485; TORRIX Ex …;TORRIX Ex C…; TORRIX Ex RS485…; TORRIX Ex TAG…; TORRIX Ex XT…; VISY-Stick … Advanced RS485; VISY-Stick … Flex RS485; TORRIX Ex …-A; TORRIX Ex … Flex; TORRIX Ex … PL; TORRIX Ex C…-A; TORRIX Ex C… Flex; TORRIX Ex C… PL; TORRIX Ex RS485…-A; TORRIX Ex RS485… Flex; TORRIX Ex RS485… PL; TORRIX Ex TAG…-A; TORRIX Ex TAG… Flex; TORRIX Ex TAG… PL; TORRIX Ex XT…-A; TORRIX Ex XT… Flex and TORRIX Ex XT… PL: For EPL Ga or EPL Ga/Gb or EPL Gb, the permissible temperature range depending on the variant and the temperature class can be taken from the following table: Temperature class T6 T5 T4 T3 T2 T1 Ambient temperature range Ii ≤ 100 mA: -40 °C … +40 °C Ii ≤ 200 mA: -40 °C … +25 °C Ii ≤ 100 mA: -40 °C … +55 °C Ii ≤ 200 mA: -40 °C … +40 °C Ii ≤ 100 mA: -40 °C … +85 °C Ii ≤ 200 mA: -40 °C … +70 °C Ii ≤ 100 mA: -40 °C … +85 °C Ii ≤ 200 mA: -40 °C … +70 °C Ii ≤ 100 mA: -40 °C … +85 °C Ii ≤ 200 mA: -40 °C … +70 °C Ii ≤ 100 mA: -40 °C … +85 °C Ii ≤ 200 mA: -40 °C … +70 °C Medium temperature range -40 °C … +75 °C -40 °C … +90 °C -40 °C … +125 °C -40 °C … +190 °C -40 °C … +285 °C -40 °C … +435 °C For EPL Db applications, the permissible ambient temperature range depending on the permissible surface temperature can be taken from the following table: Maximum surface temperature Dust layer ≤ 5 mm With total immersion T5 X°C T X°C Ii ≤ 100 mA: X°C = Ta + 40 °C Observe EN 60079-14 Ii ≤ 200 mA: X°C = Ta + 55 °C Observe EN 60079-14 Ambient temperature range Ta -40 °C … +85 °C -40 °C … +70 °C The equipment is suitable for dusts with an ignition temperature of more than 200 °C under a dust layer of 5 mm (glow temperature). This certificate may only be reproduced without any change, schedule included. Excerpts or changes shall be allowed by the TÜV NORD CERT GmbH P17-F-011 Rev. 02/11.21 Page 6/8 Schedule to EU-Type Examination Certificate No. TÜV 99 ATEX 1496 X Issue 03 VISY-Stick … TLS; VISY-Stick (Flex) Temp TLS; VISY-Stick … Advanced TLS and VISY-Stick … Flex TLS: For EPL Ga or EPL Ga/Gb or EPL Gb, the permissible temperature range can be taken from the following tables, depending on the variant and the temperature class: Temperature class T4 T3 T2 T1 Ambient temperature range -40 °C … +75 °C -40 °C … +85 °C -40 °C … +85 °C -40 °C … +85 °C Medium temperature range -40 °C … +125 °C -40 °C … +190 °C -40 °C … +285 °C -40 °C … +435 °C For EPL Db applications, the permissible ambient temperature range depending on the permissible surface temperature can be taken from the following table: Maximum surface temperature Dust layer ≤ 5 mm With total immersion T5 X°C T X°C X°C = 135 °C X°C = 135 °C X°C = Ta + 110 °C Observe EN 60079-14 Ambient temperature range Ta -40 °C … +77 °C -40 °C … +85 °C The equipment is suitable for dusts with an ignition temperature of more than 270 °C under a dust layer of 5 mm (glow temperature). TORRIX Exd XT…; TORRIX Exd …-A; TORRIX Exd … Flex and TORRIX Exd … PL: For EPL EPL Ga/Gb or EPL Gb, the permissible temperature range can be taken from the following tables, depending on the variant and the temperature class: Temperature class T6 T5 T4 T3 T2 T1 Ambient temperature range -55 °C … +50 °C -55 °C … +65 °C -55 °C … +85 °C -55 °C … +85 °C -55 °C … +85 °C -55 °C … +85 °C Medium temperature range -55 °C … +75 °C -55 °C … +90 °C -55 °C … +125 °C -55 °C … +190 °C -55 °C … +285 °C -55 °C … +435 °C For EPL Db applications, the permissible ambient temperature range depending on the permissible surface temperature can be taken from the following table: Maximum surface temperature Dust layer ≤ 5 mm With total immersion T5 X°C T X°C X°C = Ta + 30 °C Observe EN 60079-14 Ambient temperature range Ta -55 °C … +85 °C The equipment is suitable for dusts with an ignition temperature of more than 190 °C under a dust layer of 5 mm (glow temperature). (16) Drawings and documents are listed in the ATEX Assessment Report No. 22 203 302211 This certificate may only be reproduced without any change, schedule included. Excerpts or changes shall be allowed by the TÜV NORD CERT GmbH P17-F-011 Rev. 02/11.21 Page 7/8 Schedule to EU-Type Examination Certificate No. TÜV 99 ATEX 1496 X Issue 03 (17) Specific Conditions for Use: 1. The permissible temperature range depending on temperature classes resp. on the maximum surface temperature is to be taken from the operating instructions. 2. A reverse heat flow from the process, e.g. by heat dissipation from components of the system, beyond the permissible ambient temperature of the filling level sensor is not permissible. This can be avoided, for example, by suitable thermal insulation of these components or by mounting the pressure transmitter at a greater distance (cooling distance). 3. The medium tangent materials of the filling level sensor have to be resistant to the media. 4. For the uses in potentially explosive gas atmospheres and when using plastic floats, the filling level sensors have to be installed and used in such a way, that electrostatic charging from operation, maintenance and cleaning is excluded. For the uses in potentially explosive dust atmospheres and when using plastic floats process-related electrostatic charges, e.g. due to passing media have to be excluded. 5. When using titanium floats or the Sump Environmental Sensor, the ignition hazard caused by impact or friction has to be excluded. 6. For EPL Ga/Gb applications the whole device filling level type VISY-Stick … resp. type TORRIX Ex has to be mounted in a way that allows an installation that results in a sufficiently tight joint (IP66 or IP67) or a flameproof joint (IEC 60079-1) in the direction of the less endangered area. 7. In case of hazards due to pendulum or swinging, the corresponding parts of the level sensor type VISY-Stick ... resp. type TORRIX Ex... have to be effectively secured against these hazards. 8. The cable glands for the filling level sensors type TORRIX Exd XT…; TORRIX Exd …-A; TORRIX Exd … Flex and TORRIX Exd … PL have to be separately assessed and certified in accordance with EN 60079-0; EN 60079-1 and EN 60079-31. In the end-use application the degree of protection min. IP6X shall be maintained in accordance with EN 60079-0 and in compliance with EN 60529. 9. The flameproof joints at type TORRIX Exd… are not intended to be repaired. (18) Essential Health and Safety Requirements: No additional ones. - End of EU-Type Examination Certificate - This certificate may only be reproduced without any change, schedule included. Excerpts or changes shall be allowed by the TÜV NORD CERT GmbH P17-F-011 Rev. 02/11.21 Page 8/8 Notice d'instruction conformément à la directive 2014/34/UE TÜV 99 ATEX 1496 X Capteurs de niveau de type VISY-Stick … et de type TORRIX Ex… I Édition : 02.2023 Domaine d'application Les capteurs de niveau de remplissage servent à mesurer en continu les niveaux de liquides. Des flotteurs sont utilisés pour la détection du niveau de liquide. Ceux-ci coulissent sur un tube de capteur. Un deuxième flotteur peut être monté sur le tube de sonde pour la détection de l'eau ou de l’interface. On peut, en outre, déterminer la densité du liquide par le biais d'un module de densité. La chaîne de mesurage de température VISY-Stick … Temp … sert à mesurer les températures à différentes hauteurs et n’utilise pas de flotteur. L’alimentation en tension des appareils VISY-Stick … ainsi que la transmission des données de mesure à un système d’exploitation maître sont réalisées par l’intermédiaire de l’amplificateur d'isolement VP-… ou VPI ou bien, dans le cas du capteur VISY-Stick … TLS, par le biais de la console TLS-… de marque Veeder-Root, par exemple. En cas d’utilisation d’une interface RS-485, le capteur VISY-Stick … RS485 peut être utilisé. Les capteurs de niveau de remplissage TORRIX Ex … peuvent être équipés de diverses interfaces. Il s’agit p. ex. des interfaces « 4 … 20 mA » (TORRIX Ex … et TORRIX Ex C...), « RS-485 » (TORRIX Ex RS485…) ou TAG (TORRIX Ex TAG…). Les capteurs de niveau TORRIX Ex SC… sont connectés à l’amplificateur d'isolement VP-… ou VPI. II Normes L'appareil est conçu conformément aux normes européennes suivantes EN IEC 60079-0:2018 EN 60079-1:2014 EN 60079-11:2012 EN 60079-26:2015 EN 60079-31:2014 Matériel – Exigences générales Protection de l'appareil par enveloppes antidéflagrantes "d" Protection de l'équipement par sécurité intrinsèque "i" Matériel d'un niveau de protection du matériel (EPL) Ga Protection contre l’inflammation de poussières par enveloppe „t“ relative au matériel III Des instructions pour effectuer sans risques … III.a … l’utilisation L'homologation est valable pour les versions d’appareil VISY-Stick … et TORRIX Ex… Les appareils sont conçus soit comme des équipements à sécurité intrinsèque, soit comme des boîtiers antidéflagrants ou des protections par des boîtiers avec une partie à sécurité intrinsèque et sont adaptés à une utilisation dans des atmosphères potentiellement explosives. Les capteurs de niveau « Advanced » (TORRIX Ex…-A, VISY-Stick Advanced …) et « flexible » (TORRIX Ex… Flex, VISY-Stick … Flex …), de même que les types avec revêtement en plastique résistant à des liquides très agressifs peuvent (TORRIX Ex… PL) être utilisés pour tous les gaz des groupes IIA et IIB. La chaîne de mesurage de température VISY-Stick … Temp … et tous les autres capteurs de niveau peuvent être utilisés pour tous les gaz des groupes IIA, IIB et IIC. En outre, tous les appareils peuvent être utilisés pour les groupes de poussières IIIA, IIIB et IIIC. Avec le capteur de niveau en boîtier antidéflagrant ou avec protection par boîtier (TORRIX Exd …), il est possible d'utiliser un chauffage pour l'affichage en cas d'utilisation à des températures ambiantes très basses. L’utilisation d’un flotteur en plastique non conducteur en atmosphère explosive avec des gaz du groupe IIC implique une prévention des risques de charge électrostatique. Certaines conditions doivent être respectées : • L'utilisation du flotteur dans des liquides non conducteurs ayant un débit élevé est interdite ; • Aucun agitateur ne doit se trouver dans la citerne ; • Les frottements avec des éléments non conducteurs doivent être évités ; • Le flotteur ne doit pas être nettoyé à sec. Les matériaux des capteurs qui entrent en contact avec les médias doivent être résistants à ces derniers. Page 1/7 FAFNIR GmbH ⚫ Schnackenburgallee 149 c ⚫ 22525 Hamburg ⚫ Tel.: +49 / (0)40 / 39 82 07-0 ⚫ www.fafnir.de ⚫ [email protected] III.b … le montage et le démontage Le système doit être hors tension lors du montage ou du démontage. Avant l'installation, il peut être nécessaire de démonter le ou les flotteurs ou le module de densité. Lors de l'assemblage, il faut veiller à monter le(s) flotteur(s) ou le module dans le bon sens sur le tube de sonde. L’ouverture de la tête de capteur n’est prévue que pour le TORRIX Ex … avec borniers à vis. Un démontage supplémentaire risquerait d’endommager le capteur de niveau et de rendre caduque son homologation. Avec le TORRIX Exd … un presse-étoupe certifié doit être installé dans le boîtier antidéflagrant conformément aux instructions du fabricant. Les couvercles du compartiment de raccordement et de l'écran peuvent être ouverts après avoir coupé les deux circuits (capteur et chauffage) avec un temps d'attente de quatre minutes, en desserrant d'abord la vis de blocage à six pans creux M4 (visser dans le boîtier). Pour fermer le couvercle, il faut le revisser complètement et le bloquer avec la vis M4 (la visser hors du boîtier contre le couvercle). III.c … l’installation Le système doit être hors tension lors de l'installation. Il est obligatoire de respecter les prescriptions particulières comme EN 60079-14 ou les prescriptions locales relatives à l'installation. Si un appareil est livré avec support taraudé, le filetage du support taraudé doit être doté d'un produit d'étanchéité approprié, être vissé et serré dans le manchon disponible. Lors de l'installation d'un tuyau montant (Riser), le centrage en matière plastique est enfiché sur la tête de capteur. Ensuite, il faut faire glisser le capteur dans le tuyau montant (Riser) jusqu'à ce qu'il soit bien posé sur le fond de la citerne. Si le capteur de niveau est livré sans raccord process, l'installateur est responsable du respect des exigences Ex. Remarque générale (voir aussi norme EN 60079-26, paragraphe 4.3) : Si un appareil est installé dans la paroi faisant limite entre la zone 0 et la zone 1, il faut s’assurer qu’un intervalle suffisamment étanche (indice de protection IP66 ou IP67) soit atteint à l'issue de l'installation. Le raccordement du processus peut provoquer une ouverture dans la cloison de séparation vers la zone nécessitant une EPL "Ga". Il y a alors un risque de libération de gaz inflammables et de transmission de la flamme. Un retour de chaleur du processus, par exemple par rayonnement thermique, au-delà de la température ambiante admissible n'est pas autorisé. Cela peut être évité, par exemple, par une isolation thermique appropriée ou par le montage de la tête du capteur à une distance plus grande (distance de refroidissement). En cas de risques d'oscillation ou de balancement, les parties correspondantes du capteur doivent être protégées efficacement contre ces risques. Capteur de niveau flexible (TORRIX Ex… Flex …, VISY-Stick … Flex …) Ce modèle peut être réalisé avec différents pieds de sonde qui servent à stabiliser la sonde. Un pied magnétique peut faire office de support. L'aimant est alors encapsulé dans une matière plastique conductrice et peut donc être utilisé en atmosphère explosive. Si cette version est fabriquée sans support de montage, elle ne peut être utilisée que dans des liquides non coulants ou il faut s'assurer qu'elle ne bascule pas, par exemple au moyen d'un tube de protection ou d'un poids servant de base au capteur. Capteur de niveau GPL VISY-Stick … LPG … Le kit d'installation variable pour les réservoirs à gaz liquéfié GPL a été développé pour pouvoir monter et démonter le capteur de mesure à tout moment sans opérations de montage supplémentaires et sans devoir ouvrir la citerne. Le kit de montage pour réservoirs à gaz liquéfié LPG est constitué d'un tube chemisé avec flotteur LPG spécial en BUNA et d'un raccord vissé à bague coupante ¾“ NPT. Lors de l'installation avec un raccord vissé à bague coupante, il n'est plus possible de changer la position du capteur après le serrage de l'écrou-raccord. Capteur environnemental VISY-Stick Sump … Ce capteur environnemental peut être fixé au moyen d'un kit de montage. Page 2/7 FAFNIR GmbH ⚫ Schnackenburgallee 149 c ⚫ 22525 Hamburg ⚫ Tel.: +49 / (0)40 / 39 82 07-0 ⚫ www.fafnir.de ⚫ [email protected] Lors du câblage du capteur à sécurité intrinsèque au matériel associé (fil bleu de préférence), il est interdit de dépasser l’inductance et la capacité admissibles du matériel associé. Les connexions du capteur doivent être raccordées aux connexions correspondantes de l’amplificateur d'isolement. Pour les capteurs de niveau avec bornes de raccordement, les désignations des bornes sont « + » et « - » et en plus « A » et « B » pour le type TORRIX Ex… XT… (« + » et « - » sont ajoutés pour le type TORRIX Exd … pour le bornier "Heater"). Pour les appareils avec connecteur M12, l’affectation des bornes s’énonce comme suit : Pin TORRIX Ex SC… VISY-Stick … TORRIX Ex C… TORRIX Ex TAG… VISY-Stick … TLS TORRIX Ex RS485… VISY-Stick … RS485 1 + + + 2 A 3 - 4 B Câble M12 (Femelle) A (+) - B (-) Tableau 1 : Affectation des bornes des capteurs Les capteurs doivent être intégrés dans l'égalisation des potentiels de la zone dangereuse. La tête de capteur est pourvue d'une borne de connexion de liaison équipotentielle pour l'intégration des appareils dans la liaison équipotentielle. Remarque générale (voir aussi EN 60079-14:2014, paragraphe 6.4.1): Les corps d'équipement électrique ne doivent pas être raccordés séparément au système de liaison équipotentielle s'ils ont un contact métallique ferme et sûr avec des parties structurelles ou des conduites qui, à leur tour, sont connectées au système d'équipotentialité. III.d … le réglage F Aucun dispositif Ex n'est nécessaire pour l'utilisation des capteurs. III.e … la mise en service Avant la mise en service, il est impératif de contrôler la connexion et le montage de tous les appareils. L'alimentation électrique, y compris celle des appareils branchés, doit être contrôlée. Pour les capteurs de niveau de type TORRIX Exd …, l'entrée de câble et les couvercles doivent être vérifiés pour une installation correcte. III.f … la maintenance (entretien et dépannage) En principe, les appareils n'exigent aucun entretien. En cas de défectuosité, il faut renvoyer l'appareil au fabricant ou à l'une de ses représentations. Pour les appareils conçus entièrement en sécurité intrinsèque, il y a concordance lors du test de rigidité diélectrique entre le circuit électrique en sécurité intrinsèque et le châssis de l'appareil avec une tension de 500 VAC selon EN 60079-11, paragraphe 6.3.13. Pour les capteurs de niveau de type TORRIX Exd …, il n'y a pas de concordance. Avec le type TORRIX Ex… XTS… l'écran peut être remplacé. Pour ce faire, il faut d'abord retirer le couvercle de l'écran (voir section III.b). En poussant les languettes de l'écran, celui-ci peut être extrait petit à petit. En particulier avec la version TORRIX Exd …, il faut faire attention pendant cette procédure à ne pas endommager le boîtier et surtout le filetage du couvercle. Les connexions (fiches et prises) au dos de l'indicateur doivent être déconnectées. Le nouvel appareil peut maintenant être raccordé. Le nombre de pôles et la protection contre l'inversion de polarité des connecteurs déterminent le bon raccordement. Après le raccordement électrique, l'appareil est placé dans les rainures à l'aide du mécanisme d'encliquetage (l'orientation peut être modifiée ultérieurement, car l'appareil peut être tourné dans le boîtier. En appuyant à nouveau sur les languettes, l'écran peut être abaissé dans le boîtier jusqu'à ce qu'il s'enclenche. Après avoir aligné le nouvel indicateur, remettre le couvercle en place (voir section III.b). Avertissement : le modèle VISY-Stick Sump … et le flotteur en matière plastique non conductrice peuvent uniquement être nettoyés avec un chiffon humide afin de réduire le risque de charge électrostatique. Avertissement : La version TORRIX Exd … ne peut être ouverte que hors tension. Page 3/7 FAFNIR GmbH ⚫ Schnackenburgallee 149 c ⚫ 22525 Hamburg ⚫ Tel.: +49 / (0)40 / 39 82 07-0 ⚫ www.fafnir.de ⚫ [email protected] IV Marquage 1 Constructeur : FAFNIR GmbH, 22525 Hamburg 2 Désignation du type : TORRIX Ex … / VISY-Stick … 3 Numéro de certification : TÜV 99 ATEX 1496 X 4 Marquage Ex : TORRIX Ex … / TORRIX Ex C… / TORRIX Ex RS485… / TORRIX Ex SC… / TORRIX Ex TAG… / TORRIX Ex XT… / VISY-Stick … / VISY-Stick RS485… / VISY-Stick (Flex) Temp / VISY-Stick (Flex) Temp RS485 II 1 G II 1/2 G II 2 G II 2 D Ex ia IIC T6…T1 Ga Ex ia IIC T6…T1 Ga/Gb Ex ia IIC T6…T1 Gb Ex ia IIIC TX °C Db TORRIX Ex …-A / TORRIX Ex … Flex / TORRIX Ex … PL / TORRIX Ex C…-A / TORRIX Ex C… Flex / TORRIX Ex C… PL / TORRIX Ex RS485…-A / TORRIX Ex RS485… Flex / TORRIX Ex RS485… PL / TORRIX Ex SC…-A / TORRIX Ex SC… Flex / TORRIX Ex SC… PL / TORRIX Ex TAG…-A / TORRIX Ex TAG… Flex / TORRIX Ex TAG… PL / TORRIX Ex XT…-A / TORRIX Ex XT… Flex / TORRIX Ex XT… PL / VISY-Stick Advanced … / VISY-Stick … Flex … / VISY-Stick Advanced … RS485 / VISY-Stick … Flex … RS485 II 1 G II 1/2 G II 2 G II 2 D Ex ia IIB T6…T1 Ga Ex ia IIB T6…T1 Ga/Gb Ex ia IIB T6…T1 Gb Ex ia IIIC TX °C Db II 1/2 G II 2 G II 2 D Ex ia/db IIC T6…T1 Ga/Gb Ex db ia IIC T6…T1 Gb Ex ia tb IIIC TX °C Db TORRIX Exd … TORRIX Exd …-A / TORRIX Exd … Flex / TORRIX Exd … PL II 1/2 G II 2 G II 2 D Ex ia/db IIB T6…T1 Ga/Gb Ex db ia IIB T6…T1 Gb Ex ia tb IIIC TX °C Db VISY-Stick … TLS / VISY-Stick (Flex) Temp TLS II 1 G II 1/2 G II 2 G II 2 D Ex ia IIC T4…T1 Ga Ex ia IIC T4…T1 Ga/Gb Ex ia IIC T4…T1 Gb Ex ia IIIC TX °C Db VISY-Stick Advanced … TLS / VISY-Stick … Flex … TLS II 1 G II 1/2 G II 2 G II 2 D 5 Étiquette d’avertissement : * Ex ia IIB T4…T1 Ga Ex ia IIB T4…T1 Ga/Gb Ex ia IIB T4…T1 Gb Ex ia IIIC TX °C Db WARNING – Potential electrostatic charging hazard – See instructions WARNING – AFTER DE-ENERGIZING, DELAY 4 MINUTES BEFORE OPENING ** 6 Marquage CE : 0044 7 Filet Ex d : 8 Caractéristiques techniques : See instructions for technical data **Entrée de câble, par exemple M20 × 1,5 * Le marquage ne s'applique qu'aux capteurs de type VISY-Stick Sump … ** Le marquage ne s'applique qu'aux capteurs de type TORRIX Exd … Page 4/7 FAFNIR GmbH ⚫ Schnackenburgallee 149 c ⚫ 22525 Hamburg ⚫ Tel.: +49 / (0)40 / 39 82 07-0 ⚫ www.fafnir.de ⚫ [email protected] V Caractéristiques techniques Les valeurs d’entrées ci-dessous s’appliquent aux capteurs de niveau de remplissage : Grandeurs électriques TORRIX Ex SC… VISY-Stick … TORRIX Ex … TORRIX Ex C… TORRIX Ex RS485… TORRIX Ex TAG… TORRIX Ex XT… VISY-Stick … RS485 VISY-Stick … TLS 13 V Ui 15 V 30 V Ii 60 mA 100 mA / 200 mA 200 mA Pi 100 mW 1W 625 mW Ci < 10 nF 10 nF 20 nF Li < 100 µH 20 µH 410 µH * Tableau 2 : Données d’entrée électriques des capteurs de niveau de remplissage à sécurité intrinsèque La tension pour le type TORRIX Exd … est de 12 V à 50 V (Um = 253 V). Le courant est compris entre 4 mA et 20 mA (mode erreur : 3,6 mA / 21,5 mA) respectivement 10 mA en cas d'utilisation de RS-485. La tension d'alimentation de l'appareil de chauffage est de 24 V ± 10 % avec un courant de 160 mA. Lors de l'utilisation de l'équipement dans des atmosphères potentiellement explosives, veuillez consulter les tableaux 3 à 6 pour connaître les températures maximales en fonction du niveau de protection de l'équipement et de la classe de température, respectivement de la température de surface. TORRIX Ex SC… / VISY-Stick … Pour utilisation avec EPL Ga, EPL Ga/Gb et EPL Gb Classe de température Ta TF T6 -40 °C … +50 °C -40 °C … +75 °C T5 -40 °C … +65 °C -40 °C … +90 °C T4 -40 °C … +125 °C T3 -40 °C … +190 °C -40 °C … +85 °C T2 -40 °C … +285 °C T1 -40 °C … +435 °C Pour utilisation avec EPL Db Température superficielle maximale Couche de poussière ≤ 5 mm immergé dans la poussière X°C = Ta + 30 °C X°C = 135 °C Température ambiante Ta -40 °C … +85 °C Tableau 3 : Températures de service des capteurs de niveau en version de base (sans carte d’interface) L'appareil convient aux poussières dont la température d'inflammation sous une couche de poussière de 5 mm est supérieure à 190 °C (température d'incandescence). Le courant d'entrée admissible Ii dépend de la température ambiante Ta Page 5/7 * FAFNIR GmbH ⚫ Schnackenburgallee 149 c ⚫ 22525 Hamburg ⚫ Tel.: +49 / (0)40 / 39 82 07-0 ⚫ www.fafnir.de ⚫ [email protected] TORRIX Ex … / TORRIX Ex C… / TORRIX Ex RS485… / TORRIX Ex TAG… / TORRIX Ex XT… / VISY-Stick … RS485 Pour utilisation avec EPL Ga, EPL Ga/Gb et EPL Gb Classe de température Ta TF T6 Ii ≤ 100 mA: -40 °C … +40 °C Ii ≤ 200 mA: -40 °C … +25 °C -40 °C … +75 °C T5 Ii ≤ 100 mA: -40 °C … +55 °C Ii ≤ 200 mA: -40 °C … +40 °C -40 °C … +90 °C T4 -40 °C … +125 °C T3 -40 °C … +190 °C Ii ≤ 100 mA: -40 °C … +85 °C Ii ≤ 200 mA: -40 °C … +70 °C T2 -40 °C … +285 °C T1 -40 °C … +435 °C Pour utilisation avec EPL Db Température superficielle maximale Couche de poussière ≤ 5 mm immergé dans la poussière Ii ≤ 100 mA: X°C = Ta + 40 °C Température ambiante Ta -40 °C … +85 °C Note EN 60079-14 Ii ≤ 200 mA: X°C = Ta + 55 °C -40 °C … +70 °C Tableau 4 : Températures de service des capteurs de niveau avec interface 4…20 mA, RS485 ou TAG L'appareil convient aux poussières dont la température d'inflammation sous une couche de poussière de 5 mm est supérieure à 200 °C (température d'incandescence). VISY-Stick … TLS Pour utilisation avec EPL Ga, EPL Ga/Gb et EPL Gb Classe de température Ta TF T4 -40 °C … +75 °C -40 °C … +125 °C T3 -40 °C … +190 °C T2 -40 °C … +85 °C -40 °C … +285 °C T1 -40 °C … +435 °C Pour utilisation avec EPL Db Température superficielle maximale Température ambiante Ta Couche de poussière ≤ 5 mm immergé dans la poussière X°C = 135 °C X°C = 135 °C -40 °C … +77 °C X°C = Ta + 110 °C Note EN 60079-14 -40 °C … +85 °C Tableau 5 : Températures de service des capteurs de niveau avec interface TLS L'appareil convient aux poussières dont la température d'inflammation sous une couche de poussière de 5 mm est supérieure à 270 °C (température d'incandescence). Page 6/7 FAFNIR GmbH ⚫ Schnackenburgallee 149 c ⚫ 22525 Hamburg ⚫ Tel.: +49 / (0)40 / 39 82 07-0 ⚫ www.fafnir.de ⚫ [email protected] TORRIX Exd … Pour utilisation avec EPL Ga, EPL Ga/Gb et EPL Gb Classe de température Ta TF T6 -55 °C … +50 °C -55 °C … +75 °C T5 -55 °C … +65 °C -55 °C … +90 °C T4 -55 °C … +125 °C T3 -55 °C … +190 °C -55 °C … +85 °C T2 -55 °C … +285 °C T1 -55 °C … +435 °C Pour utilisation avec EPL Db Température superficielle maximale Couche de poussière ≤ 5 mm immergé dans la poussière X°C = Ta + 30 °C Note EN 60079-14 Température ambiante Ta -55 °C … +85 °C Tableau 6 : Températures de service de la version Ex d+t+i L'appareil convient aux poussières dont la température d'inflammation sous une couche de poussière de 5 mm est supérieure à 190 °C (température d'incandescence). Des mesures appropriées doivent être mises en œuvre pour s'assurer que la température au niveau de la tête de sonde ne dépasse à aucun endroit la température (T a) de la classe de température correspondante. Les capteurs de niveau atteignent un degré de protection du boîtier de : Degré de protection : VI IP68 Conditions particulières d’utilisation 1. En cas d'utilisation de flotteurs en plastique, les capteurs de niveau doivent être installés et utilisés de manière à exclure les charges électrostatiques dues au fonctionnement, à l'entretien et au nettoyage. En cas d'utilisation dans des zones à risque d'explosion de poussières, les charges électrostatiques liées au processus, par exemple en raison du passage de fluides, doivent être exclues. 2. En cas d’utilisation de flotteurs en titane ou de capteurs d’environnement Sump, il faut éviter tout risque d’inflammation résultant d’impacts ou de frottements. 3. Les joints antidéflagrants de type TORRIX Exd … ne sont pas destinés à être réparés. Page 7/7 FAFNIR GmbH ⚫ Schnackenburgallee 149 c ⚫ 22525 Hamburg ⚫ Tel.: +49 / (0)40 / 39 82 07-0 ⚫ www.fafnir.de ⚫ [email protected] Manuel de sécurité à la série standard EN 61508 Capteur de niveau type TORRIX … et type VISY-Stick … N° d'enregistrement 44 799 13752002 Manuel de sécurité à la série standard EN 61508 Capteur de niveau type TORRIX … et type VISY-Stick … I Domaine d'application Les capteurs de niveau sont conçus pour les zones où il est obligatoire d'utiliser un sous-système de sécurité conforme à la norme EN 61508 de niveau SIL 2. II Normes Les capteurs de niveau sont conçus conformément aux normes suivantes EN 61508:2010, toutes les parties Sécurité fonctionnelle des systèmes électriques/électroniques/électroniques programmables relatifs à la sécurité III Des instructions pour effectuer sans risques … III.a … l’utilisation Le présent manuel de sécurité s’applique à tous les capteurs de niveau à partir de la version matérielle 4 et à partir de la version du firmware V4.9 (capteurs) ou V1.2.0 (XTS). La lecture des numéros de version s’effectue de manière différente : TORRIX … HART… : Les numéros de version peuvent être lus à l’aide du programme de configuration FAFNIR HARTSetup. TORRIX … RS485… : La version du logiciel d’exploitation peut être lue à l’aide du protocole Modbus-ASCII. TORRIX … SC… et VISY-Stick … : Les numéros de version peuvent être lus au moyen du programme de configuration VISY-Setup ou du protocole FAFNIR Universal Device Protocol (UDP). Pour savoir quelle méthode appliquer dans quel cas, reportez-vous à la documentation technique correspondante. TORRIX … TAG… : La version du logiciel d’exploitation est régulièrement publiée dans le message d'identification. Le champ s'intitule « Firmware Version » et présente une longueur de deux octets. TORRIX … XTS… : Les numéros de version peuvent être appelés dans le menu et affichés sur l'écran intégré. En principe, le capteur de niveau indique le niveau de remplissage correct (contrôle de plausibilité) et/ou, en cas d'erreur détectée, une valeur d'erreur (état de sécurité), qui correspond à un mode de fonctionnement avec une exigence continue. L'état de sécurité est atteint dans les dix secondes. En cas d'erreur de communication, le système supérieur doit l'interpréter comme un dysfonctionnement. La sortie de la fonction de sécurité est assurée différemment par les différents capteurs de niveau. Il est important de veiller à l’absence de champs magnétiques puissants dans la zone du tube de sonde. Par ailleurs, l’utilisation sûre n’est pas garantie en présence de liquides adhérents. Page 1/7 FAFNIR GmbH Édition : 2024-08 ⚫ Schnackenburgallee 149 c ⚫ 22525 Hamburg ⚫ Tel.: +49 / (0)40 / 39 82 07-0 ⚫ www.fafnir.de ⚫ [email protected] Manuel de sécurité à la série standard EN 61508 Capteur de niveau type TORRIX … et type VISY-Stick … N° d'enregistrement 44 799 13752002 Type Homolo- Concept. Construc- Précision Concept. Température gation électrique tion de mesur. mécaniq. du processus HHT HT LLT LT NT n nB 90B B Flex … HY PL SP -5T -A5T -A I VT C HART HART C RS485 SC TAG XT XTS XTSH Tube de sonde rigide de 12 mm de diamètre n = Ø du tube de sonde, par ex. 6 (mm) n = Ø du tube de sonde ; tube de sonde non centré sur la tête de capteur Tube de sonde avant la tête de capteur courbé à 90° et Bypass Tube de sonde non centré sur la tête de capteur (Bypass) Tube de sonde flexible (pièces rigides : F = 200 / 300 mm ; T = 500 mm) Version pour utilisation dans le secteur de l'hygiène Revêtement en plastique contre les liquides très agressifs Tube de prélèvement, par ex. pour prélèvement d’échantillon Standard Avec cinq capteurs de température Plus grande précision de mesure et cinq capteurs de température Plus grande précision de mesure (Advanced) Structure standard Structure en 1.4301 (304) Structure interne résistante aux vibrations pour citernes mobiles Interface de 4 … 20 mA avec boutons de réglage internes Interface de 4 … 20 mA sans bouton de réglage Interface de 4 … 20 mA avec protocole HART et boutons de réglage internes Interface de 4 … 20 mA avec protocole HART et sans bouton de réglage Interface RS-485 Communication série (pour connexion à amplificateur d'isolement VP-… ou VPI) Interface TAG ; transmission du signal selon la norme EN 14116 Interface de RS-485 et 4 … 20 mA avec protocole HART et bouton de réglage (boîtier Ex-d) Interface de RS-485 et 4 … 20 mA avec protocole HART et bouton de réglage et affichage digital Interface de RS-485 et 4 … 20 mA avec protocole HART, bouton de réglage, affichage digital et chauffage (uniquement Exd et sans Ex) Sans homologation Ex Avec homologation Ex, sécurité intrinsèque « ia » Avec homologation Ex, boîtier antidéflagrant « d » ou protection par boîtier « t » ainsi que sécurité intrinsèque « ia » pour « … XT… » Ex Exd TORRIX Température maximale -40 °C … +450 °C Température haute -40 °C … +250 °C Température minimale -200 °C ... +80 °C Température basse -65 °C … +125 °C Température normale -40 °C … (+85) +125 °C Capteur de niveau magnétostrictif (à partir de la version 5) avec bornes de connexion ou connecteur Codification des types III.a1 : Capteur de niveau TORRIX … Page 2/7 FAFNIR GmbH Édition : 2024-08 ⚫ Schnackenburgallee 149 c ⚫ 22525 Hamburg ⚫ Tel.: +49 / (0)40 / 39 82 07-0 ⚫ www.fafnir.de ⚫ [email protected] Manuel de sécurité à la série standard EN 61508 Capteur de niveau type TORRIX … et type VISY-Stick … N° d'enregistrement 44 799 13752002 Système Type (Juste pour) Précision et Utilisation Interface Stick Sump tube de sonde RS485 TLS Biodiesel E15 Ethanol LPG N Advanced Flex Dispenser Manhole Pour connexion à amplificateur d'isolement VP-… ou VPI Pour connexion à une interface RS-485 Pour connexion à un TLS (Veeder-Root) Capteur de niveau standard Capteur de niveau ; biodiesel Capteur de niveau ; addition d’éthanol jusqu’à 15 % Capteur de niveau ; éthanol Capteur de niveau ; gaz liquéfié GLP Capteur de niveau ; AdBlue Précision de mesure standard et tube de sonde rigide Précision de mesure plus élevée Tube de sonde flexible Cuve de collecte de distributeur (sous-types possibles uniquement "interface") Trou d’homme (sous-types possibles uniquement "interface") Stick Capteur de niveau magnétostrictif avec jusqu’à cinq sondes de température dans le tube de sonde Stick Interstitial Capteur environnemental de surveillance des espaces intermédiaires des réservoirs à double paroi (sous-types possibles uniquement "interface") Stick Sump Capteur environnemental de surveillance des cuves de collectes avec distinction entre les liquides (produit/eau) VISY- Volume Information System Codification des types III.a2 : Capteur de niveau VISY-Stick … III.b … le montage et le démontage Pour les capteurs de niveau avec platine de raccordement, seul le couvercle de la tête de sonde peut être retiré pour l'installation électrique et - à l'aide de boutons-poussoirs - pour le réglage du capteur de niveau. Après le montage, le couvercle doit être refermé. Les flotteurs doivent également être retirés du tube de sonde. Lors du montage des flotteurs, faire attention à la position. III.c … l’installation La tête de capteur est pourvue d'une borne de connexion de liaison équipotentielle pour l'intégration des appareils dans la liaison équipotentielle. Pour la sécurité fonctionnelle, il est important que les sondes de mesure soient incluses dans la compensation de potentiel. Pour les capteurs de niveau avec borniers, les bornes sont désignées « + » et « - » ainsi que « A » et « B » pour le type TORRIX … XT… (« + » et « - » sont ajoutés pour le bornier chauffage « Heater » ). Pour les capteurs de niveau avec connecteur M12, l’occupation des bornes est la suivante : Broche TORRIX … SC… VISY-Stick … TORRIX … C… TORRIX … TAG… VISY-Stick … TLS TORRIX … RS485… VISY-Stick … RS485 1 + + + 2 A 3 - 4 B Câble M12 (Femelle) A (+) - B (-) Tableau III.c : Affectation des bornes des capteurs Page 3/7 FAFNIR GmbH Édition : 2024-08 ⚫ Schnackenburgallee 149 c ⚫ 22525 Hamburg ⚫ Tel.: +49 / (0)40 / 39 82 07-0 ⚫ www.fafnir.de ⚫ [email protected] Manuel de sécurité à la série standard EN 61508 Capteur de niveau type TORRIX … et type VISY-Stick … N° d'enregistrement 44 799 13752002 III.d … le réglage Aucun dispositif SIL n'est nécessaire pour l'utilisation du sous-système. III.e … la mise en service Avant la mise en service, il est impératif de contrôler la connexion et le montage de tous les appareils. L'alimentation électrique, y compris celle des appareils branchés, doit être contrôlée. III.f … la maintenance (entretien et dépannage) En principe, le capteur de mesure n'exige aucun entretien. En cas de défectuosité, il faut renvoyer l'appareil au fabricant ou à l'une de ses représentations. En cas d'erreur, par ex. pas de flotteur sur le tube de la sonde, l'erreur de diagnostic correspondante est émise. Si l'erreur est corrigée pendant le fonctionnement en service, le capteur quitte le mode erreur. Capteurs de niveau avec interface de 4 … 20 mA En cas d'erreur, le courant de défaut circule (3,6 mA ou 21,5 mA, selon le réglage effectué). Si le courant de défaut de 21,5 mA ne peut pas circuler, par exemple en cas de faible alimentation, le courant de défaut de 3,6 mA s'établit automatiquement. Si le capteur de niveau est équipé de boutons de configuration, l'état de sécurité peut également être testé à l'aide de ces boutons. Pour ce faire, il faut appuyer longuement sur une ou les deux touches et la séquence suivante se produit : • Après trois secondes, le capteur passe en mode configuration soit pour la plage de mesure (un bouton enfoncé) avec une consommation de courant de 12 mA, soit pour le courant de défaut (les deux boutons enfoncés) avec une consommation de courant de 16 mA. Ceci est indiqué par le clignotement lent de la LED (1,5 Hz). • Après dix secondes d'appui, le capteur passe à l'état de sécurité. Si 21,5 mA circulent, la LED clignote rapidement (6 Hz) et à 3,6 mA, la LED est éteinte. • Après avoir relâché le bouton, vous revenez en mode configuration. Le mode configuration est quitté au plus tard 20 secondes après le dernier actionnement et, s'il fonctionne correctement, la position actuelle du flotteur est affichée. Capteurs de niveau avec protocole HART Le deuxième octet de données de la réponse du capteur de niveau contient l'état du capteur. L'indicateur « Device Malfunction » (0x80, bit 7) signale une erreur d'appareil. Si l'indicateur « More Status Available » (0x10, bit 4) est également défini, il est possible d'interroger les bits d’état propres à l’appareil (octet 0) : Bit Erreur Description 0 Paramètres HART Les paramètres HART ont été modifiés illégalement 1 Paramètres du capteur Les paramètres du capteur ont été modifiés illégalement 2 Mesure Aucune mesure possible 3 Compteur d'erreurs Trop d'anomalies pendant la mesure 4 Sous-tension La tension d'alimentation est trop faible Tableau III.f1 : Bits d’état propres à l’appareil avec le protocole HART Page 4/7 FAFNIR GmbH Édition : 2024-08 ⚫ Schnackenburgallee 149 c ⚫ 22525 Hamburg ⚫ Tel.: +49 / (0)40 / 39 82 07-0 ⚫ www.fafnir.de ⚫ [email protected] Manuel de sécurité à la série standard EN 61508 Capteur de niveau type TORRIX … et type VISY-Stick … N° d'enregistrement 44 799 13752002 Capteurs de niveau avec protocole DDA En cas d'erreur, le code d'erreur "E102" est édité dans le champ de données du niveau de remplissage. Capteurs de niveau avec protocole H, Modbus, UC et UDP En cas d'erreur, le code d’état 1 est émis. Capteurs de niveau avec protocole LC En cas d'erreur, le bit d’état (bit 7) est réglé sur 1 dans l'octet d’état. Capteurs de niveau avec protocole TAG En cas d'erreur, le bit d'erreur (bit 23) est réglé sur 1 et le niveau de remplissage indique la cause d'erreur : Niveau de remplissage (uniquement bits 22 à 0) Informations d’état 0x000000 Problème général avec le capteur 0x000001 Erreur de RAM 0x000002 Erreur de paramètre 0x000003 Le flotteur est trop près de l'extrémité 0x000005 Le flotteur est à l'envers 0x000007 Activé (Power-up) ou remis à zéro (Reset) 0x7FFFFF Dépassement de niveau Tableau III.f2 : Bits d’état propres à l’appareil avec le protocole TAG Capteurs de niveau avec interface TLS Pour chaque mesure, les sondes sont activées pendant environ 500 ms. Si la sonde ne peut pas procéder à des mesures régulières, la mesure est marquée comme non valide car le bit de parité est faussé. Page 5/7 FAFNIR GmbH Édition : 2024-08 ⚫ Schnackenburgallee 149 c ⚫ 22525 Hamburg ⚫ Tel.: +49 / (0)40 / 39 82 07-0 ⚫ www.fafnir.de ⚫ [email protected] Manuel de sécurité à la série standard EN 61508 Capteur de niveau type TORRIX … et type VISY-Stick … N° d'enregistrement 44 799 13752002 IV Données techniques Connexion électrique et communication TORRIX …, TORRIX … C… Connexion 2 fils (interface 4 ... 20 mA ; consommation de courant de 3,8 mA à 20,5 mA pour l'affichage du niveau ; consommation de courant de 3,6 mA ou 21,5 mA en cas d'erreur ; protocole HART en option) TORRIX … RS485…, VISY-Stick … RS485 Connexion 4 fils (signaux RS 485 et alimentation ; protocole MODBUS ASCII, FDA ou FAFNIR-UD) TORRIX … SC…, VISY-Stick … Connexion 4 fils (signaux TTL et alimentation ; protocole FAFNIR) TORRIX … TAG… Connexion 2 fils (transmission du signal selon EN 14116) TORRIX … XTS… Connexion 2 fils (interface 4 ... 20 mA ; consommation de courant de 3,8 mA à 20,5 mA pour l'affichage du niveau ; consommation de courant de 3,6 mA ou 21,5 mA en cas d'erreur ; protocole HART en option) ou connexion 4 fils (RS 485 signaux et alimentation ; protocole MODBUS ASCII, FDA ou FAFNIR-UD) ainsi qu'une connexion 2 fils pour le chauffage en option VISY-Stick … TLS Connexion 2 fils (alimentation et communication via une console TLS) Alimentation TORRIX … SC… / VISY-Stick … TORRIX Ex … / VISY-Stick … RS485 TORRIX … (non Ex) TORRIX Ex XTS… TORRIX … XTS(H)… VISY-Stick … TLS 6 VDC … 15 VDC 8 VDC … 30 VDC 8 VDC … 50 VDC 12 VDC … 30 VDC 12 VDC … 50 VDC (Chauffage : 24 VDC ± 10 %) 8 VDC … 13 VDC Températures Température ambiante (tête de capteur) TORRIX … & VISY-Stick … TORRIX … XTS… TORRIX … XTSH -40 °C … +85 °C -20 °C … +85 °C -55 °C … +85 °C Température du processus (tube capteur) Standard Normale (NT) Élevé (HT) Maximum (HHT) Faible (LT) Le plus bas (LLT) -40 °C … +85 °C -40 °C … +125 °C -40 °C … +250 °C -40 °C … +450 °C -65 °C … +125 °C -200 °C … +85 °C Classe de protection grâce au boîtier Boîtier en acier inoxydable IP68 (IPX8 : 30 jours à 2 m de profondeur) Page 6/7 FAFNIR GmbH Édition : 2024-08 ⚫ Schnackenburgallee 149 c ⚫ 22525 Hamburg ⚫ Tel.: +49 / (0)40 / 39 82 07-0 ⚫ www.fafnir.de ⚫ [email protected] Manuel de sécurité à la série standard EN 61508 Capteur de niveau type TORRIX … et type VISY-Stick … N° d'enregistrement 44 799 13752002 Caractéristiques techniques relatives à la sécurité Propriété Valeur Niveau d'intégrité de sécurité SIL 2 Tolérance de panne du matériel HFT = 0 Sous-système de sécurité Type B Taux de panne [h ] λS λDD λDU TORRIX … 5,94E-07 5,83E-07 1,12E-07 TORRIX … C… 3,76E-07 4,00E-07 7,65E-08 TORRIX … HART… 7,08E-07 7,05E-07 1,39E-07 TORRIX … HART C… 4,74E-07 5,13E-07 9,52E-08 TORRIX … RS485… / VISY-Stick … RS485 2,82E-07 3,40E-07 5,43E-08 TORRIX … SC… / VISY-Stick … 1,95E-07 2,54E-07 4,49E-08 TORRIX … TAG… 3,28E-07 3,61E-07 5,75E-08 TORRIX XTS…, TORRIX Ex XTS… 4,41E-07 6,69E-07 1,14E-07 TORRIX Exd XTS… 4,95E-07 7,03E-07 1,18E-07 VISY-Stick … TLS 2,68E-07 3,79E-07 5,86E-08 -1 Fréquence moyenne de pannes dangeuses par heure, PFH [h ] Voir le taux de panne λDU Durée moyenne de rétablissement MTTR = 8 h Intervalle entre essais de sûreté T1 = 1 year Architecture 1001 -1 Tableau IV.b : Caractéristiques techniques relatives à la sécurité V Exigences supplémentaires applicables aux éléments logiciels Les éléments logiciels ne sont soumis à aucune exigence. Page 7/7 FAFNIR GmbH Édition : 2024-08 ⚫ Schnackenburgallee 149 c ⚫ 22525 Hamburg ⚫ Tel.: +49 / (0)40 / 39 82 07-0 ⚫ www.fafnir.de ⚫ [email protected] Page blanche Page blanche QR code pour accéder au site de documentation technique FAFNIR GmbH Schnackenburgallee 149 c 22525 Hambourg, Allemagne Tél. : +49 / 40 / 39 82 07 – 0 E-mail : [email protected] Web : www.fafnir.com ">
Lien public mis à jour
Le lien public vers votre chat a été mis à jour.