I V

James I.

What does the message "stop chauf." mean on the Thorix EVOLUTION and how can it be resolved?

The message "stop chauf." is displayed when the external contact is used to suspend the operation of the Thorix EVOLUTION. This typically occurs if parameter P204 is set to 1. To resolve this, check parameter P204 in the installer menu and ensure that the external contact input is not active, unless this function is intentionally desired.

G Y

Patricia G.

Which electronic board references are used for replacement on a Thorix EVOLUTION 2C?

The references for replacing electronic boards on the Thorix EVOLUTION 2C are:

  • Power electronic board: ref. B1244203
  • Display electronic board: ref. B4992185 Board replacement is required in case of an unresolvable memory error ('mEmoire err') or persistent clock error. Interventions must always be carried out with the power disconnected.