CU LED CHART
TABLEAU DES DEL DU CONTRÔLEUR
LD1
DOOR CLOSED WHEN ON
PORTE FERMÉE SI ALLUMÉ
LD2
JAM CLUTCH SENSOR ACTIVE WHEN TOGGLING
CAPTEUR BLOCAGE EMBRAYAGE ACTIF LORS DU BASCULEMENT
LD3
APS IN (GAS) ACTIVE WHEN ON
MANOSTAT GAZ PRÉSENT ACTIF QUAND ON
LD5
NOT USED
INUTILISÉ
LD11
JUMPERED ALWAYS ON/ COMPRESSOR HIGH LIMIT (VL) NO FAULT WHEN ON SAUTÉ TOUJOURS ALLUMÉ/ (VL) LIMITE SUPÉRIEURE AUCUN DEFAUT QUAND ON
LD12
COMPRESSOR LOW LIMIT (VL) FAULT WHEN ON
(VL) LIMITE BASSE DEFAUT QUAND BAS
LD13
EXTERNAL CONVEYOR START ACTIVE WHEN ON
SIGNAL DE DÉMARRAGE/CONVOYEUR TIERS ACTIF QUAND ON
LD14
EXTERNAL CONVEYOR OK ACTIVE WHEN ON
SIGNAL/CONVOYEUR TIERS OK ACTIF QUAND ON
LD16
RACK START ACTIVE WHEN ON
INTERRUPTEUR PANIER ACTIF QUAND ON
LD17
NOT USED
INUTILISÉ
LD18
NOT USED
INUTILISÉ
LD19
TABLE LIMIT SWITCH ACTIVE WHEN OFF
CONTACT DE FIN DE COURSE ACTIF QUAND ÉTEINT
LD20
POWER RINSE TANK OVER TEMP FAULT WHEN OFF
CUVE DE PRÉRINÇAGE SURTEMPÉRATURE DEFAUT A L'ARRÊT
LD21
WASH TANK OVERTEMP FAULT WHEN OFF
CUVE DE LAVAGE SURTEMPÉRATURE DEFAUT A L'ARRÊT
LD22
BOOSTER OVERTEMP FAULT WHEN OFF
SURCHAUFFEUR SURTEMPÉRATURE DEFAUT A L'ARRÊT
LD25
CU STATUS BLINK CODE
DEL CLIGNOTANT SUR L'ÉTAT DU CONTRÔLEUR
LD26
5VDC
5VDC
TEST POINT CHART
DO1
CONVEYOR 208-240V
DO5
BOOSTER FILL VALVE 120V
DO6
VENT FAN CONTROL 208-240V
DO7
RINSE PUMP 208-240V
DO8
BOOSTER HEATER 120V
DO9
TANK HEATER 120V
DO14
TANK FILL 120V
DO15
WASH TANK PUMP 208-240V
DO25
EXTERNAL BOOSTER 120V
DO26
DRAIN WATER TEMPERING/ COMPRESSOR (VL) 120V
N
NEUTRAL
GND
DIGITAL GROUND
3V3P
3.3V PROCESSOR POWER
5V_DC
INTERNAL COMPONENT POWER
5V_EXT SENSOR POWER
12V
RELAY COIL AND HMI POWER
5V_EXT_A14
SHORTED to 5V_EXT.
TABLEAU DES POINTS DE MESURE
CONVOYEUR 208-240V
VANNE DE REMPLISSAGE RÉSERVOIR 120V
COMMANDE DU VENTILATEUR 208-240V
POMPE-RINÇAGE 208-240V
CHALEUR DU SURCHAUFFEUR 120V
CHAUFFAGE-CUVE 120V
VANNE DE REMPLISSAGE RÉSERVOIR 120V
POMPE-LAVAGE 208-240V
SURCHAUFFEUR TIERS
REFROIDISSEMENT DES EAUX USÉES/ COMPRESSEUR/SYSTÈME VENTLESS 120V
NEUTRE
MISE À LA TERRE NUMÉRIQUE
PUISSANCE DU PROCESSEUR 3,3 V
PUISSANCE DU COMPOSANT INTERNE
PUISSANCE DU DÉTECTEUR
PUISSANCE BOBINE RELAIS ET IHM
REDIRIGÉ AU POINT 5V_EXT
EC A7/A4
EC1 A7
X1
EC2 A7
EC5 A6
EC A6
X5
X10
X6
X7
X2
X9
CU
F1
CON4 CON7 CON6 CON2 CON1
TB4
TB1
CON5 64/86
CON3 64/86
CON5 66/76
X1
RELAY1
TB2
RELAY2
TB8
RELAY3
TB3
X2
X3
X4
EC4 A4 FOR BLOWER DRYER
TUNNEL DE SÉCHAGE
PS1
F5 F6
ELEC 1PH
COMP?
HOBART
TB5
TB6
CL
0F-041266
REV B2
PAGE 4
">