Continental Fireplaces BLP46NTE Direct Vent Gas Fireplace spécification

Ajouter à Mes manuels
4 Des pages
Continental Fireplaces BLP46NTE Direct Vent Gas Fireplace spécification | Fixfr
ASCENT™ LINEAR PREMIUM SERIES 46 DIRECT VENT GAS FIREPLACE
Specifications
Model
BTU
BLP46
24,000
Width
Actual
Framing
46 7/8
47 3/8
Height
Actual
Framing
39 1/16
39 3/8
Depth
Actual
Framing
18 5/16 18 9/16
Viewing Area
14 1/8 x 39
Dimensions
FRONT VIEW
RIGHT SIDE VIEW
TOP VIEW
1/2" *
13mm
39 1/16"
992mm
4"
102mm
7"
178mm
22 3/4"
578mm
18 13/16" *
477mm
33 1/8"
841mm
8 11/16"
220mm
11 3/8"
289mm
42 1/2" *
1080mm
18 5/16"
465mm
4 1/2"
115mm
6 1/4"
158mm
46 7/8"
1191mm
*Finishing flange depth (the finishing flange defines the perimeter of the fireplace opening; framing or finishing materials must NEVER
encroach inside the finishing flange).
Appliance Location
Combustible Mantel Clearances
26
24
22
20
18
16
14
12
10
8
6
4
0
C
HEIGHT
MANTEL
SIDE WALL
E
B
B
B
D
C
D
1 2 3 4 5 6 7 8 9 10
MANTEL DEPTH
E
Appliance
Opening
Hood
A
Do not put objects in front of the appliance
(minimum distance of 4 feet)*
A
DIMENSIONS DE LA TABLETTE
A
B
C
18 9/16”
47 3/8”
44”
D
E
62 1/4”
6”
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada
Réf
Hauteur
A
27 1/2” (69.9cm)
Profondeur
N/A
B
12” (30.5cm)
2" (51mm)
C
14” (35.6cm)
4" (102mm)
D
16” (40.6cm)
6" (152mm)
E
18” (45.7cm)
8" (203mm)
Mantel clearances may be reduced
ONLY if the Universal Heat Management
System is installed (see Installation
Manual).
•
1(866)820-8686
•
W415-4118 / 10.07.22
www.napoleon.com
ASCENT™ LINEAR PREMIUM SERIES 46 DIRECT VENT GAS FIREPLACE
Product information provided is not complete and is subject to change without notice. Please consult the installation manual for
the most up to date installation information.
Wall Penetration
3" [76.2mm] minimum all sides for vertical venting.
Vent shield
Non-combustible
Combustible
6 1/2”
**(16.5cm)
3”
(76.2mm)
top
Center of
vent pipe
Top of
combustible
opening
14”
(35.6cm)
56”
(142.2cm)
ceiling
(min.)
46”
(117cm)*
27 1/2”
(69.9cm)
0” if non-combustible finishing
is used such as brick and stone.
1”(25.4mm)
to vent sides
3”
(76.2mm)
* See “venting requirements” and “venting installation” sections.
** Clearances within the enclosure may be higher, see
“minimum framing dimensions” section.
1”
(25.4mm)
bottom
Top of
appliance
opening
Non-combustible
material
note:
The vent shield is telescopic and
must be adjusted to shield the
full depth of the combustible wall
penetration.
0” to back standoffs
Combustible
material
0” to side standoffs
1”
(25.4mm)
0” to bottom of the
appliance
Framing
•
! WARNING
Do not build into this area - it must be left clear to provide adequate clearance for the vent in this 14”
(35.6cm) wide area centered along the front of the appliance. The appliance should be in its final location
before framing.
J**
Ceiling
CEILING
COMBUSTIBLE
HEADER
G
MINIMUM
FROM
BASE
OF
APPLIANCE
H
14”
[35.6cm]
MIN
Drywall
DRYWALL
F
F*
A
B
A
B
B
47 3/8”
H
84”
F
39 3/8”
A
18 9/16”
I
3 1/2”
G
56”
* Allow for finished floor and hearth
thickness when setting these
dimensions.
** 2” x 4” frame can be “backed”
with 3/4” ply to support TV mounting
hardware.
W415-4118 / 10.07.22
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada
•
1(866)820-8686
•
www.napoleon.com
FOYER À GAZ VENTILÉ DIRECTE SÉRIES ASCENT LINÉAIRE PRIME 46
MD
Spécifications
Modèle
BTU
BLP46
24,000
Largeur
Réel
Ossature
46 7/8
47 3/8
Hauteur
Réel
Ossature
39 1/16
39 3/8
Profondeur
Réel
Ossature
18 5/16 18 9/16
Dimensions de Vision
14 1/8 x 39
Dimensions
VUE DEVIEW
FACE
FRONT
VUE
DE CÔTÉ
VUE
DE DESSUS
RIGHT
SIDE DROITE
VIEW
TOP
VIEW
1/2" *
13mm
39 1/16"
992mm
4"
102mm
7"
178mm
22 3/4"
578mm
18 13/16" *
477mm
33 1/8"
841mm
8 11/16"
220mm
11 3/8"
289mm
42 1/2" *
1080mm
4 1/2"
115mm
6 1/4"
158mm
18 5/16"
465mm
46 7/8"
1191mm
*La profondeur de la bride definition (la bride de finition définit le périmètre de l’ouverture de la cheminée; les matériaux de
charpente ou de finition NE JAMAIS empiété à l’intérieur de la bride de finition).
Dégagements Combustibles de la
Tablette
Emplacement de l’appareil
C
MUR DU CÔTÉ
E
B
B
B
C
D
E
Ouverture de
Appliance
l’Appareil
Opening
Hotte
Hood
D
A
placez
d’objetsindevant
(distance
DoNenot
putpas
objects
frontl’appareil
of the appliance
minimum de 4 pieds)*
(minimum distance of 4 feet)*
A
DIMENSIONS DE TABLETTE
A
B
C
18 9/16”
47 3/8”
44”
D
E
62 1/4”
6”
Réf
Hauteur
B
12” (30.5cm)
Profondeur
2" (51mm)
C
14” (35.6cm)
4" (102mm)
D
16” (40.6cm)
6" (152mm)
E
18” (45.7cm)
8" (203mm)
Les dégagements de la tablette peuvent
être réduites SEULEMENT si la système
de gestion de chaleur universelle est
installée (voir la manuel d’installation).
W415-4118 / 10.07.22
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada
•
1(866)820-8686
•
www.napoleon.com
FOYER À GAZ VENTILÉ DIRECTE SÉRIES ASCENT LINÉAIRE PRIME 46
MD
L’information du produit fourni n’est pas complet et est sujet de changer sans préavis. Consultez le manuel d’installation pour plus
d’information d’installation actuel.
Pénétration du Mur
3" [76.2mm] minimum all
sides
ford’évacation
vertical venting.
toute
côtés
verticale.
Vent shield
L’écran
protecteur
Combustible
Incombustible
Non-combustible
6 1/2”
(16.5cm)
**
Center of
vent pipe
Dessus
Top ofde
l’ouverture
combustible
opening
combustible
14”
(35.6cm)
56”
(142.2cm)
Plafond
ceiling
(min.)
46”
(116.8cm)*
3”
0” (0mm) si les
(76.2mm) matériaux
0” if non-combustible
finishing
incombustibles
sont
top
is usedcomme
such aslabrick
andou
stone.
utiliser
brique
la pierre.
1” (25,4mm) des côtés d’évent
3”
(76.2mm)
** Dégagements dedans l’enceinte peut être
élevés, voir la section « dimensions minimaux de
l’encadrement ».
1”
(25.4mm)
bottom de
Dessus
Top of
appliance
opening
l’ouverture
de l’appareil
Matériau
Non-combustible
incombustible
material
* Voir la section « évacuation ».
0” pour retourner les impasses
27 1/2” Matériau
Combustible
(69.9cm) combustible
material
0” aux contraintes
latérales
1”
(25.4mm)
note:
L’écran protecteur est téléscopique et doivent
être ajusté à protection toute la profondeur de la
pénétration de la paroi combustible.
0” vers le bas de
l’appareil
Ossature
•
! AVERTISSEMENT
Ne construisez pas dans cet espace de 14” (35,6cm) de largeur, centré le long de
l’avant de l’appareil. Cet espace doit resté libre afin d’offrir un dégagement adéquat pour
l’évacuation. Aucun matériaux combustible n’est permis.
J**
Ceiling
PLAFOND
CEILING
PLAFOND
TÊTE
COMBUSTIBLE
HEADER
COMBUSTIBLE
G
MINIMUM
MINIMUM
FROM À
PARTIR
BASEDE
LA BASE DE
OF
L’APPAREIL
APPLIANCE
H
14”
[35.6cm]
MIN
CLOISON
Drywall
SÈCHE
CLOISON
DRYWALL
SÈCHE
F
F*
A
B
A
B
B
47 3/8”
H
84”
F
39 3/8”
A
18 9/16”
I
3 1/2”
G
56”
* Tenez compte de l’épaisseur du plancher et du foyer
lorsque vous définissez ces dimensions.
** Le cadre de 2” x 4” peut être « renforcé » avec
une pièce contraplaqué d’un épaisseur de 3/4” pour
supporter le matériel de montage du téléviseur.
W415-4118 / 10.07.22
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada
•
1(866)820-8686
•
www.napoleon.com