W R

Michael W.

How to replace fuses?
To replace the fuses, follow these instructions: Replace all 3 fuses at the same time and do not reuse already used fuses. It is recommended not to place your hand in the middle of the fuse. Fit the lower part of the fuse fully into the lower tulip contact, then fit the upper part of the fuse into the upper contact. Check that the field spreader is correctly replaced and orient the label towards the front side. For striker fuses: Install the striker fuses, whose melting triggers the switch. The end of the fuse equipped with the striker is marked. The characteristics and direction of assembly of the fuse are printed on the body. Orient the label on the front side with the striker at the top.
F N

Linda F.

What does the rated continuous thermal current represent for electrical devices?
The rated continuous thermal current represents the maximum current value that an electrical device can continuously withstand without overheating excessively. It is the value of continuous current that can flow through the device for an extended period without the device's temperature reaching a dangerous limit, as defined by standards and manufacturer specifications. Exceeding this value can lead to damage, failures, or fires.
F N

Linda F.

What is the rated continuous thermal current for an electrical device?
The rated continuous thermal current represents the maximum current value that the device can continuously withstand without excessive overheating. Exceeding this value can lead to damage, failures, or fires. This rating depends on factors defined by standards and manufacturer specifications.
W R

Michael W.

How to replace the fuses?
To replace the fuses, follow these instructions: 1. Change all 3 fuses at once when replacing a fuse. Do not reuse fuses that have already been used. 2. Schneider Electric recommends not placing your hand in the middle of the fuse. 3. Fit the lower part of the fuse all the way into the lower tulip contact. 4. Then, fit the upper part of the fuse into the upper contact. 5. Check that the field spreader is correctly replaced. 6. Orient the label towards the front. For striker fuses: * Install the striker fuses; their fusing triggers the switch. The end of the fuse equipped with the striker (A) is marked. The characteristics and mounting directions of the fuse are printed on the body. Orient the label to the front (striker at the top).