John B.

How to force a shutdown of a pellet stove if the remote control is not working?

To force a shutdown of the pellet stove, particularly if the remote control is faulty or its batteries are depleted, use the emergency panel located at the back of the stove. On this panel, find selector 'D' (a three-position selector for functionality) and move it to the 'OFF' position. This action will manually turn off the stove. Once the remote control issue is resolved and you wish to use it again, remember to return selector 'D' to the 'REMOTE' position, otherwise the stove will not respond to remote commands.

Q B

James Q.

How to adjust or restore ventilation settings on the MAX remote control?

From the main screen, press key D to access the VENTILATION setting. Use key C to select the desired ventilation level (1 to 5) or the 'auto' option. Return to the main screen by briefly pressing key A or leaving the keypad idle for 7 seconds. If using a replacement remote that does not control ventilation, turn the remote on, press and hold keys D and E together for 10 seconds until a flashing number appears, select 1, 2, or 3 using key C according to the stove model, and confirm with key E.

Q B

James Q.

How to set the ventilation on the MAX remote control?

From the main screen, press button D to access the VENTILATION setting. Use button C to select the desired level (1 to 5) or the 'auto' option. Press button A briefly or leave the remote inactive for 7 seconds to return to the home screen.

Q B

James Q.

How to adjust or reset the ventilation on the MAX remote control?

To access ventilation settings, press D, select the desired level with C, and press A to return. To reset or configure the remote, hold D and E for 10 seconds until a number flashes, select 1, 2, or 3 with C, and confirm with E.

Q B

James Q.

What are the functions of the emergency panel controls?

The emergency panel includes an OFF/REMOTE/ON selector for operation without a remote, a MIN/MED/MAX power selector, a diagnostic button, and a pairing button for the remote control.