What troubleshooting steps should be taken in case of no 12V power in the cell?

In case of no 12V power: 1. Ensure the main 12V switch on the control panel is in the "on" position. 2. Check that the battery disconnector (item 12 on the EBL 99 block) is in the "on" position. 3. Verify that the cell battery voltage is above 10.5 V; otherwise, the total discharge protection has cut off consumers (the battery must be recharged). 4. Inspect the plug-in fuses on the front of the EBL 99. 5. Check that all plugs are properly inserted into the electrical block. If the battery is completely discharged, it is possible to start the vehicle's engine to temporarily power the consumers.

P G

Mary P.

What should be checked in case of 12V power loss in a cell equipped with the EBL 99 I electrical block?

In case of 12V power loss, you should check: the main 12 V switch on your control panel, the battery disconnector (item 12 on the EBL 99), the deep discharge protection (if battery voltage is < 10.5 V), the plug-in fuses, and all connections on the electrical block.