CL
0F-041260
TB10
PITB?01
POUR LES CONNEXIONS
ÉLECTRIQUES, UTILISER DU
FIL EN CUIVRE D'UNE
RÉSISTANCE MINIMALE DE
90°C À LA TENSION INDIQUÉE
SUR LA PLAQUE
SIGNALÉTIQUE
PITB?0401
PITB?04
PITB?0401
PITB?02
PITB?04
PITB?01
PITB?0401
PITB?02
PITB?04
RINÇAGE (RPS1 & RPS2) 1.5A @ TENSION D'ALIMENTATION
DE LA PLAQUE SIGNALÉTIQUE, "ACTIF" PENDANT LE RINÇAGE
VENT FAN CONTROL (VFC1 & VFC2) 1HP @ 120VAC/ 2.5HP @ 240VAC,
SWITCHING CIRCUIT "ON" WHEN MACHINE ON OR ON A TIMER
COMMANDE DU VENTILATEUR (VFC1 & VFC2) 1HP @ 120VAC/ 2.5HP @ 240VAC,
"ACTIF" LORSQUE LA MACHINE EST EN MARCHE OU SUR UNE MINUTERIE
PIHEATER?0401
PIHEATER?05
PIHEATER?0502
COF??
PIHEATER?04010101
PITB?01
PITB?02
REMOVE HEATER WIRES FROM TB10 POSITION RETIRER LES CÂBLES DE L'ÉLÉMENT
DE LA POSITION TB10, 4, 5, ET 6.
4, 5, AND 6. JUMPER THE REMOVED WIRES
JOINDRE LES CÂBLES RETIRÉS
TOGETHER USING THE PROVIDED JUMPER
ENSEMBLE À L'AIDE DU CAVALIER LIVRÉ
PIHEATER?040101
PITB?04
PIHEATER?0501
HTR3
REMOVE HEATER WIRES FROM TB10 POSITION
7, 8, 9, 10, 11, AND 12. INSULATE ENDS AND SECURE WIRES
PITB1004
RETIRER LES CÂBLES DE L'ÉLÉMENT DE LA POSITION TB10, 7, 8, 9, 10, 11 ET 12.
ISOLER LES BOUTS ET SÉCURISER LES CÂBLES
COTB6
TB6
BSTREN1
6
BSTREN2
5
REMOVE JUMPER AT TB6
PIN 5 AND 6 FOR NON-BOOSTER
PITB601
PITB60401
PITB602
PITB604
RETIRER LE CAVALIER SUR LES POINTS TB5 ET 6 SI SANS SURCHAUFFEUR
PIHEATER?0401
PIHEATER?05
PIHEATER?040101
PIHEATER?0502
PIHEATER?04010101
PIHEATER?0501
PITB?04
PITB?0401
PITB?02
PITB?04
PITB?02
PITB?04
PITB1001
PITB100401
PITB1002
PITB1004
3KW 44/66
PITB10S 10 1
HTR2
REMOVE HEATER WIRES FROM TB10 POSITION RETIRER LES CÂBLES DE L'ÉLÉMENT
DE LA POSITION TB10, 4, 5, ET 6.
4, 5, AND 6. JUMPER THE REMOVED WIRES
JOINDRE LES CÂBLES RETIRÉS
TOGETHER USING THE PROVIDED JUMPER
ENSEMBLE À L'AIDE DU CAVALIER LIVRÉ
PITB?04
PITB?01
PITB10S0102
PITB10S01010
CHALEUR DU
SURCHAUFFEUR
PIWAGO?0S010101
PITB?0401
PITB?02
BOOSTER HEATER
COWAGO?
PIWAGO?0S0103
PIHEATER?0401
PIHEATER?05
PIHEATER?040101
PIHEATER?0502
PIHEATER?04010101
PIHEATER?0501
BOOSTER HEATER
HTR3
CHALEUR DU
SURCHAUFFEUR
9KW 44/66
PITB10S0101 01
PITB10S01
PITB10S0103
PITB10S0101
COTB1
TB1
PITB10S0106
PITB10S0104
PITB10S
PITB10S0105
PITB10S0107
PITB10S0109
PITB10S02
PITB10S0108
64/86
REMOVE FOR
DUAL POINT
NON-BOOSTER
SERVICE CONNECTION
AT TB1 AND TB2
RETIRER POUR DEUX POINTS
SI SANS SURCHAUFFEUR
CONNEXION AU SERVICE
À TB1 ET TB2
-4 PITB20S01010
REFERENCE FORM 0F-046016
CONVERSION DU SURCHAUFFEUR À 12 KW
FORMULAIRE DE RÉFÉRENCE 0F-046016
TB10
COTB10
1 COTB?
BOOSTER HEATER
HTR2 RED
CHALEUR DU
2
SURCHAUFFEUR
HTR2 BLK
12KW 54/64/76/86
3
HTR2 BLU
HTR2
4
HTR2 REDPITB?04
5
HTR2 BLK
6
HTR2 BLU
7
HTR3 RED
8
PITB?02 HTR3 BLK
COF?
9
HTR3 BLU
HTR3
10
HTR3 RED
11
REMOVE HEATER WIRES FROM TB10 POSITION
HTR3 BLK
7,
8,
9, 10, 11, AND 12. INSULATE ENDS AND SECURE WIRES
12
HTR3 BLU
PITB?01
PITB?0401
PITB?02
PITB?04
COHEATR?
PITB?01
PIHEATER?0401
PIHEATER?05
PIHEATER?040101
PIHEATER?0502
PIHEATER?04010101
PIHEATER?0501
-6
PITB20S0101 01
64/86
PITB20S01
PITB20S0103
PITB20S0101
PITB20S0106
PITB20S0107
PITB20S0101
54/64/76/86 12KW BOOSTER CONVERSION
PITB20S0102
COTB2 PITB20S0105
TB2
-5
PITB20S0104
PITB20S
PITB20S0109
PITB20S02
PITB20S0108
REMOVE FOR
THREE POINT
WITH BOOSTER
SERVICE CONNECTION
AT TB1,TB2, AND TB8
RETIRER POUR TROIS POINTS
AVEC SURCHAUFFEUR
CONNEXION AU SERVICE
À TB1, TB2, ET TB8
-7
PITB30S 10
PITB30S0102
PITB30S01
PITB30S0103
PITB30S0101
PITB?0401
-8
PITB30S0101
L2
CONTRÔLE DU SURCHAUFEUR TIERS (BSTR1 & BSTR2) 0,15A @ 120 VOLTS
"EN MARCHE" SI L'APPAREIL EST EN MARCHE
HTR2
PITB?0401
PITB?02
L1
EXTERNAL BOOSTER CONTROL (BSTR1 & BSTR2) 0.15A @ 120VAC
"ON" WHEN MACHINE ON
3KW 44/66
4KW 54/64/76/86
1
HTR2 RED
2
HTR2 BLK
3
HTR2 BLU
4
HTR2 RED
PITB?01
5 PITB?0401
HTR2 BLK
6
HTR2 BLU
7
HTR3 RED
8
HTR3 BLK
PITB?01
9 PITB?0401
HTR3 BLU
10
HTR3 RED
11
HTR3 BLK
12
HTR3 BLU
PITB?01
L3
RINSE (RPS1 & RPS2) 1.5A @ NAMEPLATE SUPPLY VOLTAGE
"ON" DURING RINSE CYCLE
PITB100401
CHALEUR DU
SURCHAUFFEUR
L2
DÉTERGENT (DPS1 & DPS2) 1,5A @ TENSION D'ALIMENTATION
DE LA PLAQUE SIGNALÉTIQUE, "ACTIF" PENDANT LE LAVAGE
PIHEATER?0501
PIWAGO0S010101
PITB?04
PITB?01
PITB1002
PIHEATER?04010101
COWAGO
L1
DETERGENT (DPS1 & DPS2) 1.5A @ NAMEPLATE SUPPLY VOLTAGE
"ON" DURING WASH CYCLE
PIWAGO0S0103
PITB?0401
PITB?02
PITB1001
PIHEATER?05
PIHEATER?0502
PITB?04
PITB?01
BOOSTER HEATER
PIWAGO0S0102
PIHEATER?0401
PIHEATER?040101
PIWAGO?0S0102
L3
1PITB?0401
HTR2 RED
2
HTR2 BLK
3
HTR2 BLU
4
HTR2 RED
5
HTR2 BLK
6
HTR2 BLU
7
HTR3 RED
8
HTR3 BLK
9
HTR3 BLU
10
HTR3 RED
11
HTR3 BLK
12
HTR3 BLU
PITB?02
REFERENCE FORM 0F-046019
CONVERSION DEPUIS UN SEUL POINT DE CONNEXION À DEUX OU TROIS POINTS
FORMULAIRE DE RÉFÉRENCE 0F-046019
TB10
PITB?01
PITB?02
FOR SUPPLY
CONNECTION USE
COPPER WIRE
SUITABLE FOR 90°C
MINIMUM AND FOR
VOLTAGE LISTED ON
THE DATA PLATE
REFERENCE FORM 0F-046016
CONVERSION DU SURCHAUFFEUR À 12 KW
FORMULAIRE DE RÉFÉRENCE 0F-046016
L2
AVERTISSEMENT
LES RACCORDEMENTS ÉLECTRIQUES ET LA MISE À
LA TERRE DOIVENT ÊTRE CONFORMES AUX
NORMES CONCERNÉES DU CODE CANADÍEN DE
L'ÉLECTRICITÉ ÉDITION LA PLUS RÉCENTE
ET/OU DE TOUT ÀUTRE CODE D'ÉLECTRICITÉ ÉN
VIGUEUR.
SINGLE POINT TO DUAL POINT
OR THREE POINT CONVERSION
44/66 12KW BOOSTER CONVERSION
NON-BOOSTER CONVERSION
REFERENCE FORM 0F-046016
CONVERSION SI SANS SURCHAUFFEUR
FORMULAIRE DE RÉFÉRENCE 0F-046016
L1
REV B2
PAGE 3
WARNING
ELECTRICAL AND GROUNDING CONNECTIONS
MUST COMPLY WITH THE APPLICABLE
PORTIONS OF THE NATIONAL ELECTRICAL
CODE, ANSI/NFPA 70, LATEST EDITION,
AND/OR OTHER LOCAL ELECTRICAL CODES.
W AGO?
COMP?
HOBART
W AGO
ELEC
COTB3
TB3
PITB30S0106
PITB30S0104
PITB30S
PITB30S0105
PITB?02
PITB?01
PITB?0401
PITB30S0101 01
PITB30S0107
L3
-9
PITB30S0109
PITB30S02
PITB30S0108
PITB?02
PITB?04
PITB?01
PITB?0401
PIHEATER?0401
PIHEATER?05
PIHEATER?0502
PIHEATER?04010101
PIHEATER?0501
PITB?04
PITB?0401
PITB?02
PITB?04
PITB1001
PITB100401
PITB1004
RETIRER LES CÂBLES DE L'ÉLÉMENT DE LA POSITION TB10, 7, 8, 9, 10, 11 ET 12.
ISOLER LES BOUTS ET SÉCURISER LES CÂBLES
PITB80S01010
PITB80S01
PITB80S0103
PITB80S0101
-11
PITB80S01011
-12 PITB80S0101101
L3
PITB1002
RETIRER POUR DEUX POINTS
AVEC SURCHAUFFEUR
CONNEXION AU SERVICE
À TB1, ET TB8
PITB80S0102
-10
L2
PITB?01
REMOVE FOR
DUAL POINT
WITH BOOSTER
SERVICE CONNECTION
AT TB1 AND TB8
L1
PIHEATER?040101
44/54/64/66/76/86
PITB80S0106
COTB8
TB8
PITB80S0104
PITB80S
PITB80S0105
PITB80S 107
PITB80S0109
PITB80S02
PITB80S0108
64/86
ONLY
SEULEMENT
">