PG 8591 | Miele PG 8593 Laboratory glassware washer Manuel utilisateur
Ajouter à Mes manuels10 Des pages
▼
Scroll to page 2
of
10
Installation Plan / Plan d’installation PG 8591 – PG 8593 Mat. no. Version 10 344 180 00 en, fr - CA Technical data sheet PG 8591 Washer-disinfector PG 8593 Laboratory Glassware Washer PG 8591 - 8593 Legend: Circled, bold-type abbreviations: Connection required Abbreviations surrounded by broken circle: Connection optional or required, depending on model Electrical connection (PG 8591) Electrical connection (PG 8591) Electrical connection (240V Option PG8591) Electrical connection (240V Option PG8591) Electrical connection (PG 8593) Electrical connection (PG 8593) Voltage (default) 2 AC 208V 60 Hz 2 AC 208V 60 Hz Rated load 6.2 kW 6.2 kW Fuse rating 2 x 30 A 2 x 30 A Minimum cross-section 3 × AWG 10 3 × 5.2 mm² Length of electrical cord (UL 921) with plug approx. 5‘9“ approx. 1.8 m Electrical connection NEMA L6-30 NEMA L6-30 Voltage (convertible) 3 AC 208V 60 Hz 3 AC 208V 60 Hz Rated load 6.2 kW 6.2 kW Fuse rating 3 x 20 A 3 x 20 A Minimum cross-section 4 × AWG 12 4 × 3.3 mm² Length of electrical cord (UL 921) with plug approx. 5‘9“ approx. 1.8 m Electrical connection NEMA L15-20 NEMA L15-20 Voltage (default) 2 AC 240V 60 Hz 2 AC 240V 60 Hz Rated load 6.2 kW 6.2 kW Fuse rating 2 x 30 A 2 x 30 A Minimum cross-section 3 × AWG 10 3 × 5.2 mm² Length of electrical cord (UL 921) with plug approx. 5‘9“ approx. 1.8 m Electrical connection NEMA L6-30 NEMA L6-30 Voltage (convertible) 3 AC 240V 60 Hz 3 AC 240V 60 Hz Rated load 6.2 kW 6.2 kW Fuse rating 3 x 20 A 3 x 20 A Minimum cross-section 4 × AWG 12 4 × 3.3 mm² Length of electrical cord (UL 921) with plug approx. 5‘9“ approx. 1.8 m Electrical connection NEMA L15-20 NEMA L15-20 Voltage (default) 3 AC 208V 60 Hz 3 AC 208V 60 Hz Rated load 6.2 kW 6.2 kW Fuse rating 3 x 20 A 3 x 20 A Minimum cross-section 4 × AWG 12 4 × 3.3 mm² Length of electrical cord (UL 921) with plug approx. 5‘9“ approx. 1.8 m Electrical connection NEMA L15-20 NEMA L15-20 Voltage (convertible) 2 AC 208V 60 Hz 2 AC 208V 60 Hz Rated load 6.2 kW 6.2 kW Fuse rating 2 x 30 A 2 x 30 A Minimum cross-section 3 × AWG 10 3 × 5.2 mm² Length of electrical cord (UL 921) with plug approx. 5‘9“ approx. 1.8 m Electrical connection NEMA L6-30 NEMA L6-30 Installation plan / Schéma d'implantation PG 8591 – PG 8593 Date created / Date de création: 13.11.2015 M.-Nr. 10 344 180 / 00 Page 2 / 10 The machine is supplied with electrical cord and plug. The receptacle must be accessible after machine installation. For hard-wired machines, connection should be made via a suitable mains switch with all-pole isolation. The contact opening between all open contacts must be at least 3 mm wide and the mains switch must be lockable in the open position. If necessary, an equipotential bond with good contact connection must be provided in accordance with all appropriate national and local regulations. Splash protection class IP 21 Equipotential bonding and earthing There is a screw connection point at the back of the machine, to which equipotential bonding can be connected if required. Network/ printer connection (optional) Optional machine interface for transmission or process data output Communication module (not supplied) Ethernet module or RS232 module (install electrical sockets near machine if required) Connections/installation must comply with IEC 60950. Cold Water Two cold water connections are required for machines with steam condenser (DK). Use supplied Y-adapter if only one cold water connection is available. Hot Water Connection Demineralised water (DI) Connect equipotential bonding and protective earth conductor! Max. temperature 68 °F 20 °C Max. water hardness 73 gpg 70 °dH Recommended flow pressure 29 psi 200 kPa Min. flow pressure 14.5 psi 100 kPa Max. pressure 145 psi 1,000 kPa Throughput 2 gal/min 7.5 l/min Connection thread - on site (flat sealing) 3/4“ Male Garden 3/4“ Male Garden Hose Thread Hose Thread Length of connection hose (supplied) approx. 5‘ 7“ approx. 1.7 m Length of the steam condenser hose approx. 5‘ 7“ approx. 1.7 m Max. temperature 150 °F 65 °C Max. water hardness 73 gpg 70 °dH Recommended flow pressure 29 psi 200 kPa Min. flow pressure 5.8 psi 40 kPa Max. pressure 145 psi 1,000 kPa Throughput 2 gal/min 7.5 l/min Connection thread - on site (flat sealing) 3/4“ Male Garden 3/4“ Male Garden Hose Thread Hose Thread Length of connection hose (supplied) approx. 5‘ 7“ approx. 1.7 m Max. temperature 150 °F 65 °C Recommended flow pressure 29 psi 200 kPa Min. flow pressure 4.4 psi 30 kPa Max. pressure 145 psi 1,000 kPa Connection thread - on site (flat sealing) 3/4“ Male Garden 3/4“ Male Garden Hose Thread Hose Thread Throughput 2 gal/min 7.5 l/min Length of connection hose (supplied) approx. 5‘ 7“ approx. 1.7 m Hose from supply container to machine to be fitted on site. Installation plan / Schéma d'implantation PG 8591 – PG 8593 Date created / Date de création: 13.11.2015 M.-Nr. 10 344 180 / 00 Page 3 / 10 Drain Water Drainage temperature 200 °F 93 °C Length of drain hose approx. 4’ 6” approx. 1.4 m Drain hose, max. drainage length approx. 13’ 1” approx. 4.0 m Drain pump head height from floor level, max. approx. 3’ 3” approx. 1 m Drain hose delivery, max. 4.2 gal/min 16 l/min On-site hose connector (external diameter x length) 7/8” × 1 3/16” 22 mm × 30 mm It is advisable to lay the drain hose in a curve min. 600 mm above floor level to the drainage point. External dispensing (optional) Connection for up to two dispensing units for liquid agents on the back panel. (note machine model) Machine feet Height-adjustable 0-2 3/8“ 0 – 60 mm Foot diameter 1 3/8“ 35 mm Entry point into housing 8M 8M Heat Dissipation to Room Heat transfer by emission 1,194 btu/h 0.35 kWh/h Load on removal 1,365 btu/h 0.40 kWh/h Machine data Height 32 7/8“ 835 mm Height without lid 32 1/4“ 820 mm Width 23 5/8“ 598 mm Depth 23 5/8“ 598 mm Door height 24 1/2“ 622 mm Net weight 172 lbs 78 kg Dynamic floor load 1,200 N 1,200 N Width including transport pallet 26 3/8“ 670 mm Depth including transport pallet 29 3/8“ 740 mm Height including transport pallet 36 1/4“ 920 mm Ambient temperature 40-105 °F 5-40 °C Max. humidity 80% 80% Max. altitude above sea level 4,921‘ 1,500 m Set-up Conditions It is essential to observe the installation instructions when installing the machine. In order to reduce the risk of steam damage, the area around the machine should be limited to furniture and fittings that are designed for use in commercial environments. Installation should only be performed by Miele Service or authorized installers in accordance with valid regulations, relevant standards and health and safety codes! Subject to change! Installation plan / Schéma d'implantation PG 8591 – PG 8593 Date created / Date de création: 13.11.2015 M.-Nr. 10 344 180 / 00 Page 4 / 10 Caractéristiques techniques PG8591 Laveur-désinfecteur PG8593 Laveur de verrerie laboratoire PG 8591 - 8593 Légende: Raccordement électrique (PG8591) Raccordement électrique (PG8591) Raccordement électrique (240V Option PG8591) Raccordement électrique (240V Option PG8591) Raccordement électrique (PG8593) Raccordement électrique (PG8593) Signification des symboles entourés d’un cercle continu. Raccordement nécessaire. Signification des symboles entourés d’un cercle discontinu. Raccordement optionnel ou en fonction de la machine. Tension (à la livraison) Puissance de raccordement Fusible Câble d’alimentation, section minimum Longueur du câble de raccordement (UL 921) avec fiche Fiche Tension (commutable) Puissance de raccordement Fusible Câble d’alimentation, section minimum Longueur du câble de raccordement (UL 921) Fiche Tension (à la livraison) Puissance de raccordement Fusible Câble d’alimentation, section minimum Longueur du câble de raccordement (UL 921) avec fiche Fiche Tension (commutable) Puissance de raccordement Fusible Câble d’alimentation, section minimum Longueur du câble de raccordement (UL 921) Fiche Tension (à la livraison) Puissance de raccordement Fusible Câble d’alimentation, section minimum Longueur du câble de raccordement (UL 921) avec fiche Fiche Tension (commutable) Puissance de raccordement Fusible Câble d’alimentation, section minimum Longueur du câble de raccordement (UL 921) Fiche Installation plan / Schéma d'implantation PG 8591 – PG 8593 Date created / Date de création: 13.11.2015 2 AC 208V 60 Hz 6.2 kW 2 x 30 A 3 × AWG 10 2 AC 208V 60 Hz 6.2 kW 2 x 30 A 3 × 5.2 mm² Env. 5‘9“ Env. 1.8 m NEMA L6-30 3 AC 208V 60 Hz 6.2 kW 3 x 20 A 4 × AWG 12 Env. 5‘9“ NEMA L15-20 2 AC 240V 60 Hz 6.2 kW 2 x 30 A 3 × AWG 10 NEMA L6-30 3 AC 208V 60 Hz 6.2 kW 3 x 20 A 4 × 3.3 mm² Env. 1.8 m NEMA L15-20 2 AC 240V 60 Hz 6.2 kW 2 x 30 A 3 × 5.2 mm² Env. 5‘9“ Env. 1.8 m NEMA L6-30 3 AC 240V 60 Hz 6.2 kW 3 x 20 A 4 × AWG 12 Env. 5‘9“ NEMA L15-20 3 AC 208V 60 Hz 6.2 kW 3 x 20 A 4 × AWG 12 NEMA L6-30 3 AC 240V 60 Hz 6.2 kW 3 x 20 A 4 × 3.3 mm² Env. 1.8 m NEMA L15-20 3 AC 208V 60 Hz 6.2 kW 3 x 20 A 4 × 3.3 mm² Env. 5‘9“ Env. 1.8 m NEMA L15-20 2 AC 208V 60 Hz 6.2 kW 2 x 30 A 3 × AWG 10 Env. 5‘9“ NEMA L6-30 NEMA L15-20 2 AC 208V 60 Hz 6.2 kW 2 x 30 A 3 × 5.2 mm² Env. 1.8 m NEMA L6-30 M.-Nr. 10 344 180 / 00 Page 5 / 10 L’appareil est fourni avec un câble de raccordement et une fiche. La prise doit être accessible après l’installation de l’appareil. En cas de raccordement fixe de l’appareil, il faut prévoir un interrupteur principal équipé d'un dispositif de disjonction phases et neutre et une ouverture de contact d'au moins 3 mm et doit pouvoir être fermé dans la position zéro. Conformément aux prescriptions nationales et internationales, une liaison équipotentielle doit être établie. Classe de protection IP21 Liaison équipotentielle et terre Pour effectuer le branchement d'une liaison équipotentielle, une vis de branchement est disponible à l'arrière de l’appareil. La liaison équipotentielle et la terre doivent être raccordées ! Raccordement réseau/ imprimante (option) Interfaces côté machine en option pour le transfert ou l'impression de données de cycle. Modules de communication (non fournis) : Module Ethernet ou module RS232 (Installer si nécessaire des prises au niveau de l'appareil.) Les raccordements/installations doivent être effectués conformément à IEC 60950. Eau froide Deux raccordements à l'eau froide sont nécessaires pour les variantes de machines avec condensateur vapeur (DK). Le cas échéant, raccorder le deuxième tuyau d’eau froide avec l’élément en "Y" joint. Eau chaude Température max. 68 °F 20 °C Dureté de l’eau max. admissible 73 gpg 70 °dH Pression recommandée 29 psi 200 kPa Pression minimale 14.5 psi 100 kPa Pression maximale 145 psi 1,000 kPa Débit volumétrique 2 gal/min 7.5 l/min Raccord fileté à prévoir par l'exploitant (joint plat) ¾ po, filage d’arrosage, mâle ¾ po, filage d’arrosage, mâle Longueur tuyau de raccordement eau froide env. 5‘ 7“ env. 1.7 m Longueur du tuyau de raccordement du condenseur vapeur env. 5‘ 7“ env. 1.7 m Température max. 150 °F 65 °C Dureté de l’eau max. admissible 73 gpg 70 °dH Pression recommandée 29 psi 200 kPa Pression minimale 5.8 psi 40 kPa Pression maximale 145 psi 1,000 kPa Débit volumétrique 2 gal/min 7.5 l/min Raccord fileté à prévoir par l'exploitant (joint plat) ¾ po, filage d’arrosage, mâle ¾ po, filage d’arrosage, mâle Longueur tuyau de raccordement eau chaude env. 5‘ 7“ env. 1.7 m Installation plan / Schéma d'implantation PG 8591 – PG 8593 Date created / Date de création: 13.11.2015 M.-Nr. 10 344 180 / 00 Page 6 / 10 Eau déminéralisée Vidange Température max. 150 °F 65 °C Pression recommandée (AD résistant à la pression) 29 psi 200 kPa Pression minimale 4.4 psi 30 kPa Pression maximale (AD résistant à la pression) 145 psi 1,000 kPa Débit volumétrique ¾ po, filage d’arrosage, mâle ¾ po, filage d’arrosage, mâle Raccord fileté à prévoir par l'exploitant (joint plat) 2 gal/min 7.5 l/min Longueur tuyau de raccordement eau déminéralisée env. 5‘ 7“ env. 1.7 m Température de l'eau de vidange 200 °F 93 °C Longueur du tuyau de vidange env. 4’ 6” env. 1.4 m Longueur max. de la rallonge du tuyau de vidange env. 13’ 1” env. 4.0 m Hauteur de refoulement de la pompe de vidange à partir du rebord inférieur de l'appareil (max.) env. 3’ 3” env. 1 m Débit volumétrique temporaire max. de la vidange 4.2 gal/min 16 l/min Obturateur à prévoir par l’utilisateur par tuyau de vidange (da × l) 7/8” × 1 3/16” 22 mm × 30 mm Il est conseillé de guider dans la vidange, le tuyau de vidange dans un coude de 600 mm min. au-dessus du bord supérieur du sol fini. Dosage externe Raccordement jusqu'à deux dispositifs de dosage pour produits liquides sur la paroi (en option) arrière. (Respecter le modèle de l'appareil) Socle Emission de chaleur dans la pièce d'installation Caractéristiques Hauteur réglable 0-2 3/8“ 0 – 60 mm Diamètre du socle 1 3/8“ 35 mm Emplacement pour les pieds de l'appareil 8M 8M Emission de chaleur par rayonnement 1,194 btu/h 0.35 kWh/h Emission de chaleur par produit de rinçage lors de prélèvement 1,365 btu/h 0.40 kWh/h Hauteur avec couvercle 32 7/8“ 835 mm Hauteur d’encastrement 32 1/4“ 820 mm Largeur 23 5/8“ 598 mm Profondeur 23 5/8“ 598 mm Hauteur de la porte 24 1/2“ 622 mm Poids net 172 lbs 78 kg Charge au sol en fonctionnement 1,200 N 1,200 N Largeur de chargement minimale de l’appareil avec palette de transport 26 3/8“ 670 mm Profondeur de chargement minimale de l’appareil avec palette de transport 29 3/8“ 740 mm Hauteur de chargement minimale de l’appareil avec palette de transport 36 1/4“ 920 mm Installation plan / Schéma d'implantation PG 8591 – PG 8593 Date created / Date de création: 13.11.2015 M.-Nr. 10 344 180 / 00 Page 7 / 10 Conditions d’installation Température ambiante 40-105 °F 5-40 °C Humidité relative de l'air max 80% 80% Hauteur d'installation max. au-dessus du niveau de 4,921‘ la mer (NN) 1,500 m Respectez impérativement les instructions de montage lors de l'installation de l’appareil. Il est conseillé de n’utiliser que des meubles adaptés à un usage industriel à proximité de l'appareil afin d’éviter les dommages éventuels provoqués par la condensation. L’installation doit exclusivement être effectuée par le Service Miele ou des installateurs agréés, conformément aux prescriptions et aux règlements et aux règlements de prévention des accidents en vigueur. Sous réserve de modifications ! Installation plan / Schéma d'implantation PG 8591 – PG 8593 Date created / Date de création: 13.11.2015 M.-Nr. 10 344 180 / 00 Page 8 / 10 AW Drain water NW Network and printer connection DK Cold water connection, steam condenser PA Equipotential bonding DS External dispensing system connection VE Demineralized water connection WW Hot water connection Raccordement réseau et à une imprimante (en option) Liaison équipotentielle EL Electrical connection KW Cold water connection AW Vidange NW DK Raccordement eau froide pour condensateur PA DS Raccordement Dosage externe (en option) VE Raccordement à l'eau déminéralisée EL Branchement électrique WW Raccordement à l'eau chaude KW Raccordement eau froide Installation plan / Schéma d'implantation PG 8591 – PG 8593 Date created / Date de création: 13.11.2015 M.-Nr. 10 344 180 / 00 Page 9 / 10 AW Drain water NW Network and printer connection DK Cold water connection, steam condenser PA Equipotential bonding DS External dispensing system connection VE Demineralized water connection WW Hot water connection Raccordement réseau et à une imprimante (en option) Liaison équipotentielle EL Electrical connection KW Cold water connection AW Vidange NW DK Raccordement eau froide pour condensateur PA DS Raccordement Dosage externe (en option) VE Raccordement à l'eau déminéralisée EL Branchement électrique WW Raccordement à l'eau chaude KW Raccordement eau froide Installation plan / Schéma d'implantation PG 8591 – PG 8593 Date created / Date de création: 13.11.2015 M.-Nr. 10 344 180 / 00 Page 10 / 10