WM14DINAV63HR2XXAX | WM14DINAV63HO2S1AX | WM14DINAV63HO2XXAX | WM14DINAV63LO2S1AX | WM14DINAV63LO2XXAX | WM14DINAV63HXXS1AX | WM14DINAV63HXXXXAX | WM14DINAV53LR2S1AX | WM14DINAV53LR2XXAX | WM14DINAV53LO2S1AX | Installation manual | CARLO GAVAZZI WM14DINAV63HR2S1AX Guide d'installation
Add to My manuals4 Pages
▼
Scroll to page 2
of
4
SETUP OUT2 WM14DIN A/WM1496 A Instrument instruction sheet OUT1 or OUT2 Three Phase power analyser S Measuring mode S SETUP ALARMS d 0...100 (%) RESET S S S S S S 1...32 RESET S S S S S S 1...255 RESET S S S S S S 4,8 - 9,6 - 19,2 - 38,4 0...999 S S Uncorrect password S S Correct password S S Main menu S 0...999 S S S S S S 3P.n- 3P.1 - 3P.A - 3P - 2P - 1P S S S S Measuring mode 1 1...999 S S E W dmd max A dmd max A1 max A2 max A3 max WL1 max WL2 max WL3 max VL1 max VL2 max VL3 max PF1 min PF2 min PF3 min A1 min A2 min A3 min VL1 min VL2 min VL3 min 1.0...99.9 S F S S S ■ RESET AND ACCESS TO THE MAIN MENU S.rE : resets all minimum and maximum stored values (see table “F”). P.rE : resets all maximum stored values (see table “E”). E.P.r: resets kvarh/kWh partial counters. PAS : if you enter the correct password (the default password is 0) you access to the main menu. ■ THE MAIN MENU FUNCTIONS n_P : new password, change password function. SYS : electrical system, choose the correct electrical system; 3P.n: 3-phase unbalanced with or without neutral; 3P.A: 3-phase ARON; 3P: 3-phase balanced without neutral; 3P.I: 3-phase balanced with neutral (requires only one voltage input “VL1-N” and one current input “I1)”; 2P: twophase, 1P: single phase. Ct.r : CT ratio, “dP” selects the position of the decimal point and the of the “k” or “M” multiplyer. “Ct.r” selects the required CT value from 1 to 999. Example: if the primary of the CT being connected is 300kA and the secondary is 5A, the CT ratio corresponds to 60,0k (obtained from the calculation: 300000/5). Ut.r : VT ratio. “dp” selects the decimal point position and the VT ratio “k” or “M” multiplyer . “Ut.r” selects the required VT ratio from 1 to 999. Example: if the primary of the VT being connected is 5kV and the secondary is 100V, the VT ratio will be 50 (given by 5000/100). P.i.t. : integration time for the calculation of power dmd: select the required value from 1 to 30 minutes. A.i.t: current integration time of thermical current: select the required value from 1 to 30 minutes. thd : selects whether to activate (YES) or deactivate (NO) the harmonic analysis. ou.1 / ou.2 : selects the type of output among: pulses, alarm or remote control. See the relevant instructions on the following page. SEt : setting of alarm output parameters. See the relevant instructions on the following page. Fis : filtering range programming to set the operating range of the digital filter. The value is expressed as % of the full scale value. Fic : selection of filtering coefficient value from 1 to 32. Increasing the value, also the stability and the settling time of the measurements are increased. Adr : instrument serial port address: from 1 to 255. Bdr : baudrate selection (38.400; 19.200; 9.600; 4.800). H.rE: reset of the hour counter. E.tr: reset of the total and partial energy counters. End : to confirm the new selected values press the S key, or press ▲ ▼ to remain in the programming menu. ■ RESET E ACCESSO AL MENÙ PRINCIPALE S.rE : azzera tutti i valori minimi e massimi memorizzati (vedi tabella “F”). P.rE : azzera i valori massimi memorizzati (vedi tabella “E”). E.P.r : azzera i contatori kvarh/kWh parziali. PAS : inserendo il valore di password corretto (di default 0) si accede al menù principale. ■ LE FUNZIONI DEL MENÙ PRINCIPALE n_P : nuova password, personalizza la password. SYS : sistema elettrico, scegliere il sistema elettrico corretto: 3P.n: trifase sbilanciato con o senza neutro, 3P.A: trifase ARON, 3P: trifase bilanciato senza neutro, 3P.I: trifase bilanciato con neutro (richiede un solo ingresso voltmetrico “VL1-N” e un ingresso amperometrico “I1”), 2P: bifase, 1P: monofase. Ct.r : rapporto TA. “dP” seleziona la posizione del punto decimale e il moltiplicatore del rapporto TA “k” o “M”. “Ct.r” seleziona il valore del rapporto TA richiesto da 1 a 999. Esempio: se il primario del TA ha una corrente di 300kA e il secondario di 5A, il rapporto TA corrisponde a 60,0k (ottenuto eseguendo il calcolo: 300000/5). Ut.r : rapporto TV. “dP” seleziona la posizione del punto decimale e il moltiplicatore del rapporto TV “k” o “M”. “Ut.r” seleziona il valore TV richiesto da 1 a 999. Esempio: se il primario del TV connesso è di 5kV e il secondario è di 100V il rapporto di TV corrisponde a 50 (ottenuto eseguendo il calcolo: 5000/100). P.i.t: tempo di integrazione per il calcolo della potenza media: selezionare il tempo desiderato da 1 a 30 minuti. A.i.t: tempo di integrazione per il calcolo della corrente termica: selezionare il valore desiderato da 1 a 30 minuti. thd : seleziona se attivare l’analisi armonica (YES) o disattivare l’analisi armonica (no). ou.1 / ou.2 : selezione del tipo di uscita: impulsi, allarme o remoto. Vedere le istruzioni dedicate nella pagina seguente. SEt : impostazioni parametri uscita allarme. Vedere le istruzioni dedicate nella pagina seguente. Fis : selezione del campo di intervento del filtro digitale espresso in % del valore di fondo scala. Fic : selezione del coefficiente di filtraggio da 1 a 32. Aumentando il coefficiente aumenta la stabilità e il tempo di assestamento delle misure. Adr : indirizzo seriale: da 1 a 255. Bdr : seleziona la velocità di trasmissione dati (38.400; 19.200; 9.600; 4.800). h.rE: azzeramento del conta ore. E.tr: azzeramento dei contatori di energia totali e parziali. End : per confermare i dati impostati e tornare al modo misura premere S , o ▲ ▼ per restare nel menù di programmazione. ■ RÜCKSETZEN UND DAS HAUPTMENÜ AUFRUFEN S.rE : rücksetzen aller gespeicherten Mindest. und Max. Werte (siehe Tafel “F” ). P.rE : rücksetzen aller gespeicherten max. Werte (siehe Tafel “E”). E.P.r : rücksetzen der kvarh/kWh Teilzähler. PAS : Wenn Sie das richtige Passwort eingeben, gelangen Sie in das Hauptmenü (das Standard-Passwort ist 0) . ■ DIE FUNKTIONEN DES HAUPTMENÜS n_P : Neues Passwort, Passwortfunktion ändern. SYS : Wahl der korrekten Systemart: 3P.n: unsymmetrische Last, 3Phasen mit oder ohne Nulleiter; 3P.A: 3-Phasig ARON, 3P: 3Phasig symmetrische Last ohne Nulleiter; 3P.I: 3-Phasig symmetrische mit Nulleiter (nur ein Spannungseingang “VL1-N” und ein Stromeingang “I1” notwendig), 2P: 2-Phasig, 1P: 1-Phasig. Ct.r: Stromwandler Verhältnis; “dP” Wahl der Dezimalpunktposition und “k” oder “M” als Multiplikators des Stromwandler Verhältnis; “Ct.r” Wahl des Stromwandlerverhältnisses von 1 bis 999. Beispiel: Bei dem Primärstrom des Wandlers von 300kA und einem Sekundärstrom 5A ergibt sich das Verhältnis zu 60,0k (Quotient 300000/5). Ut.r: Spannungswandler Verhältnis; “dP” Wahl der Position des Dezimalpunktes und “k” oder “M” als Multiplikators des Spannungswandler Verhältnis. “Ut.r” Wahl des Spannungswandlerverhältnisses von 1 bis 999. Beispiel: Bei einer Primärspannung des Wandlers von 5 kV und einer Sekundärspannung 100 V, ergibt sich das Verhältnis zu 50 (Quotient 5000 V/100 V). P.i.t. : Integrationszeit der Leistung dmd: Wert zwischen 1 und 30 Minuten wählen. A.i.t: Integrationszeit für Stromintegral: wählen sie den gewünschten Wert von 1 bis 30 Minuten. thd : Wahl ob das harmonische Analyse aktivierien (YES) oder deaktivieren (no). ou.1 / ou.2 : Wahl des Ausgangstyp: Impuls, Alarm oder Schaltausgang. Siehe Anleitungen auf folgenden Seiten. SEt : Einstellungen Parameter Alarmausgang. Siehe Anleitungen auf folgenden Seiten. Fis : Arbeitsbereich des Digitalfilters wählen. Der Wert wird in % vom Vollbereichs-wert angegeben. Fic : Filterkoeffizient von 1 bis 32 wahlen. Bei einem größeren Wert erhöhen sich auch die Stabilität und die Einstellzeit für die Messungen. Adr : Adresse der seriellen Schnittstelle zwischen 1 und 255 einstellen. Bdr : Wahl von Baudrate (38.400; 19.200; 9.600; 4.800). H.rE: Rücksetzen der Stundenzähler. E.tr: Rücksetzen der Teil und Gesamt -Energiezähler. End: Ende: neuen Wert durch Drücken von S bestätigen oder durch ▲ ▼ Drücken im Hauptmenü bleiben. WARNING: if WARNING: if VLN x IL x Ct.r x Ut.r x 3 ≥ 999.999.999 (999M), the instrument displays “Err” . VLN: phase-neutral line voltage or VT seconday voltage. IL: CT secondary current. Ct.r: CT ratio. Ut.r: TV ratio. ATTENZIONE: se VLN x IL x Ct.r x Ut.r x 3 ≥ 999.999.999 (999M), lo strumento indica “Err” . VLN: tensione fase-neutro dell’impianto (VLN), oppure del secondario TV. IL: corrente secondario del TA . Ct.r: rapporto TA. Ut.r: rapporto TV . WARNUNG: erreicht VLN x IL x Ct.r x Ut.r x 3 den Wert: 999.999.999 (999M), ist die Anzeige “Err”. VLN: NetzPhasen-Neutralsspannung oder Sekundärspannung der Spannungswandler; IL: Sekundärstrom; Ct.r: Stromwandlersverhältnis Ut.r: Spannungswandlersverhältnis. S SYS= 3p.n V k A M L 1 VA ▲ S Hz al al Hz al ▲ h Hz M al ▲ A M L 1 al ▲ Hz A M L 1 al ▲ var Hz k A M L 1 al ▲ h Hz al ▲ h var L 3 Hz PF dmd Phase sequence: 123 or 132 k M W L 2 var L 3 V A VA W L 2 PF dmd Asymmetry V LL fig. 9 V VA h L 3 PF dmd V12, V23, V31 k W L 2 var ATENCIÓN: si VLN x IL x Ct.r x Ut.r x 3 ≥ 999.999.999 (999M), el equipo visualiza “Err” . VLN: tensión de línea fase-neutro o tensión del secundario del trafo de tensión. IL: intensidad del secundario del trafo de intensidad. Ct.r: relación del trafo de intensidad. Ut.r: relación del trafo de tensión. fig. 8 V VA h L 3 PF dmd V LL sys, PF sys k W L 2 var Hz fig. 7 V VA h L 3 PF dmd V LN sys, PF sys A L 1 W L 2 var L 3 k ■ LAS FUNCIONES DEL MENÚ PRINCIPAL n_P : nueva clave, función de cambio de clave. SYS : selección del sistema eléctrico adecuado: 3P.n: sistema trifásico, carga desequilibrada con o sin neutro, 3P.A: trifásico ARON, 3P: sistema trifásico, carga equilibrada sin neutro, 3P.I: sistema trifásico, carga equilibrada con neutro (necesita de una sola entrada de tensión “VL1-N” y una entrada de intensidad “I1”), 2P: sistema bifásico, 1P: sistema monofásico. Ct.r : relación del trafo de intensidad (CT); “dP” selección del punto decimal y el multiplicador “k” o “M” del trafo de intensidad. “Ct.r” selecciona el valor del trafo de intensidad necesario de 1 a 999. Ejemplo: si el primario del CT conectado es de 300kA y el secundario de 5A, la relación del CT será 60,0k (cantidad obtenida del cálculo: 300000/5). Ut.r : relación del trafo de tensión (VT). “dP” selecciona el punto decimal y el multiplicador “k” o “M” del trafo de tensión. “Ut.r” selecciona el valor del trafo de tensión de 1 a 999. Ejemplo: si el primario del VT conectado es de 5kV y el secundario es 100V, la relación del VT será 50 (resultante de 5000/100). P.i.t. : tiempo de integración para el cálculo de la potencia dmd: selección del valor deseado de 1 a 30 minutos. A.i.t: tiempo de integración para el cálculo de la intensidad térmica: seleccionar el valor deseado de 1 a 30 minutos. thd : selección de la activación (YES) o desactivación (NO) del análisis de armónicos. ou.1 / ou.2 : selección tipo de salida: pulsos, alarma o remota. Leer las instrucciones en la pagina siguente. SEt : ajuste parámetros salida alarma. Leer las instrucciones en la pagina siguente. Fis : programación del rango de filtrado para ajustar la escala operativa del filtro digital. Se expresa en % del valor de la escala completa. Fic : Selección del coeficiente de filtrado desde 1 hasta 32. A medida que aumenta este valor, aumenta también la estabilidad y el tiempo de respuesta de las medidas. Adr : dirección del puerto serie del instrumento: de 1 a 255. Bdr : selección de la velocidad en baudios de transmisión datos (38.400; 19.200; 9.600; 4.800). H.rE: puesta a cero del contador horario. E.tr: puesta a cero de los contadores de energía totales y parcial. End : para confirmar los nuevos valores seleccionados y volver al modo medida pulse S , o para restar en las funciones del menú de programación pulse ▲ ▼ . ATTENTION: si VLN x IL x Ct.r x Ut.r x 3 ≥ 999.999.999 (999M), l’appareil affiche “Err” . VLN: tension de ligne phaseneutre ou tension du secundaire TT; . IL: courant secundaire du TC. Ct.r: ratio TC; Ut.r: ratio TT . fig. 6 V VA W L 2 PF dmd V L1, V L2, V L3 M k M L 1 VA L 2 ▲ W h L 3 var Hz al PF dmd An, Hz fig. 12 V k A M L 1 VA L 2 ▲ To next page Alla pagina succesiva Zu folgende Seite A la page suivante A la página siguiente fig. 11 V A ▲ W h L 3 var Hz al PF dmd W1, W2, W3 L 2 k A M L 1 ▲ W var Hz V k A M L 1 VA h L 3 fig. 14 fig. 13 V VA ▲ SETUP ALARMS L 1 L 2 ▲ SETUP OUT2 fig. 10 al W1 dmd, W2 dmd, W3 dmd ▲ W h L 3 var Hz al PF dmd PF dmd PF 1, PF 2, PF 3 fig. 15 V k al PF dmd A L1, A L2, A L3 A M fig. 16 L 1 L 2 ▲ W h L 3 var Hz al PF dmd var L1, var L2, var L3 V k A M L 1 VA VA ▲ c ▲ var L 3 A L 1 VA h var k ■ PUESTA A CERO Y ACCESO AL MENÚ PRINCIPAL S.rE : puesta a cero de los valores min. y max. almacenados (veer tabla “F”). P.rE : puesta a cero de los valores max. almacenados (ver tabla “E”). E.P.r : puesta a cero de los contadores kvarh/kWh parciales. PAS : al introducir la clave correcta (la clave por defecto es 0), se accede al menú principal. A L1 dmd, A L2 dmd, A L3 dmd SETUP OUT1 OUT1 or OUT2 S M fig. 5 V ▲ h L 3 var Hz al PF dmd VA L1, VA L2, VA L3 fig. 17 V k A M L 1 L 2 ▲ W h L 3 var Hz al PF dmd VA sys, W sys, var sys fig. 18 V k A M L 1 VA VA W L 2 ▲ S A L 1 ▲ b k W L 2 PF dmd Asymmetry V LN S ▲ Hz V VA h L 3 PF dmd a M W L 2 var L 3 A L 1 ▲ h S k ▲ ▲ fig. 4 fig. 3 V VA W L 2 S fig. 2 1 ▲ S L 1 ▲ fig. 1 S S ESPAÑOL ■ FUNCIONES DEL TECLADO S Permite entrar en el modo de programación y confirmar el valor programado. ▲ En el modo de medida: para desplazarse a la siguiente variable visualizada. En el modo de programación: para desplazarse a la siguiente función o para aumentar el valor del parámetro. ▼ En el modo de medida: para desplazarse a la última variable visualizada. En el modo de program.: para desplazarse a la última función o reducir el valor del parámetro. ■ REMISE À ZÉRO ET ACCÈS AU MENU PRINCIPAL S.rE : remise a zéro de tous les valeurs min, et max. mémorisées (voir table “F”). P.rE : remise a zéro de tous les valeurs maxi mémorisées (voir table “E”). E.P.r : remise a zéro de tous les compteurs kvarh/kWh partiels. PAS: la saisie du mot de passe correct (0 par défaut) donne accès au menu principal. ■ FONCTIONS DU MENU PRINCIPAL n_P: fonction nouveau mot de passe, fonction changer mot de passe. SYS : réseau électrique, choisir le réseau électrique correct: 3P.n: 3-Phases charge non équilibrée avec ou sans neutre; 3P.A: 3-Phases ARON; 3P:3-Phases équilibré sans neutre, 3P.I: 3-Phases équilibré avec neutre (avec seulement une entrée du tension “VL1-N” et une entrée de courant “I1”), 2P: 2-Phases, 1P: 1-Phase. Ct.r : ratio du transformateur de courant “dP” sélection du point decimal et le multiplicateur “k” ou “M” du transformateur de courant “Ct.r”; sélection du ratio du transformateur de courant de 1 à 999. Exemple: si le primaire du TC raccordé est de 300kA et si le secondaire est de 5A, le ratio TC correspond à 60,0k (soit 300000 divisé par 5) . Ut.r : ratio du transformateur de tension. “dP” sélection du point decimal et le multiplicateur “k” ou “M” du transformateur de tension. “Ut.r” sélection de la valeur du transformateur de tension de 1 à 999. Exemple: si le primaire du TT raccordé est de 5kV et si le secondaire est de 100V, le ratio TT sera de 50 (soit 5000 divisé par 100). P.i.t.: temps d'intégration pour le calcule de la puissance dmd: sélectionner la valeur nécessaire entre 1 et 30 minutes. A.i.t: temps d'intégration pour le calcule du courant thermique: sélectionner la valeur désirée de 1 à 30 minutes. thd : sélection si activer l’analyse harmonique (YES) ou la desactiver (no). ou.1 / ou.2 : sélection type de sortie: impulsions, alarme ou remote. Voir les instructions à la page suivante. SEt : réglages paramètres sortie alarme. Voir les instructions à la page suivante. Fis: la programmation de la gamme de filtrage permet de définir la plage de fonctionnement du filtre numérique. La valeur est exprimée en pourcentage de la valeur en échelle totale. Fic: sélection de la gamme de filtrage de 1 à 32. Lorsqu'on augmente cette valeur, on augmente également la stabilité et le temps de stabilisation des mesures augmente également. Adr: Adresse du port série: de 1 à 255. Bdr : sélection de debit baud de données (38.400; 19.200; 9.600; 4.800). H.rE: remise à zéro des compteurs horaires E.tr: remise à zéro des compteurs d’énergie totales et partiels. End: pour confirmer les nouvelles valeurs sélectionnées, appuyer sur la touche S , ou appuyer sur la touche ▲ ▼ pour revenir aux fonctions du menu de programmation. L 2 ▲ S VA dmd max FRANÇAIS ■ FONCTIONS CLAVIER S Accès à la phase programmation et confirmation des valeurs. ▲ En mode mesure: affiche la variable suivante. En mode programmation: affiche la fonction suivante ou augmente la valeur du paramètre. ▼ En mode mesure: affiche la variable précédente. En mode programmation: affiche la fonction précédente ou diminue la valeur du paramètre. ▲ W h L 3 L 2 ▲ S DEUTSCH ■ TASTENFUNKTIONEN S Programmiermodus aktivieren und eingegebenen Wert bestätigen. ▲ Im Meßodus: zur nächsten anzuzeigenden Netzgröße ‘blättern’. Im Programmiermodus: zur nächsten Funktion ‘blättern’ oder den Parameterwert erhöhen. ▼ Im Meßmodus: Zur vorherigen anzuzeigenden Netzgröße ‘blättern’. Im Programmiermodus: Zur vorherigen Funktion ‘blättern’ oder den Parameterwert verringern. var Hz al • k M VA ▲ W •• h L 3 PF dmd VA dmd, W dmd, Hz V A var Hz al PF dmd MAX: V, A(•), W(••) ▲ 1 ITALIANO ■ FUNZIONI DELLA TASTIERA S Accede al modo programmazione e conferma i valori selezionati. ▲ Nel modo misura: passa alla visualizzazione della pagina misura successiva. Nel modo programmazione: passa alla funzione successiva o incrementa i valori. ▼ Nel modo misura: passa alla visualizzazione della pagina misura precedente. Nel modo programmazione: passa alla funzione precedente o decrementa i valori. ▲ S WM14DIN/96 A IM ML 200508 Cod. 8020688 ENGLISH ■ KEY PAD FUNCTIONS S Access to the programming phase and value confirmation. ▲ On measuring mode: scroll to the next displayed system variable. On programming mode: scroll to the next function or parameter value increase. ▼ On measuring mode: scroll to the previously displayed system variable. On programming mode: scroll to the previous function or parameter value decrease. ▲ C o m p o n e n t s ▲ A u t o m a t i o n ▲ Carlo Gavazzi Controls SpA, Via Safforze, 8 - 32100 Belluno (Italy) Tel. +39 0437 931000, Fax +39 0437 931021 CARLO GAVAZZI 2 S S S S ■ ALARM SETUP MENU A.O1 : “oFF” disables the alarm A.01, moving to the next one (up to A.16). Any other previously selected setting remains stored. “on” enables the alarm, then select the variable to be controlled: VAr : select the variable to be controlled (see table “ I”). no, to go straight to the settings of the next alarm. YES, to continue the programming of all other parameters relating to the alarm being set: d.P.o : disable the alarm at power on, “no” to disable the function or “YES” to enable it. tYP : select the alarm type: up (uP) or down (do), in window alarm (in), out window alarm (out). dP : select the position of the decimal point. Lo.S : select the value of the low setpoint. Hi.S : select the value of the high setpoint. dEL : select the delay time on activation from 0 to 255 seconds. S S S S S S S S S S S S S ALARM TYPE UP DO IN OUT 1.11 9.99 11.1 99.9 111 999 1.11K 9.99K 11.1 K 99.9K 111K 999K 1.11M S S MAX VALUE DECIMAL POINT S S 9.99M 11.1M 99.9M 111M 999M Fun : select the OR or AND function (see the “OR/AND” picture below) out : select the relay to be enabled in case of alarm. “rl.1” relay output 1 or “rl.2” relay output 2. d S S S S S S IMPORTANT NOTES: • The measured variable blinks when an alarm occurs (see figure “G” on the left: VL1, 200V). It’s possible to link more than one alarm to the same variable, the first alarm condition will make the variable range blink. The “al” (•) LED shows the activation of one of the two outputs (relay or open collector output) in case they are selected as alarm. • When both digital outputs are installed in the instrument (relay or open collector), it’s possible to manage up to 16 alarms that can be linked to output 1 and/or output 2. • If “var” or “W are negative, the decimal point on the very right blinks in correspondence with the negative variable (see figure “H” on the left). • If the instrument displays a negative power, the relevant energy will not be counted. G L 1 V k A M ■ SAFETY PRECAUTIONS Carefully read the instruction manual. If the instrument is used in a way which is not specified by the builder,the protection may be impaired. Maintenance: To keep the intrument clean,use a damp cloth; do not use abrasives or solvents. We suggest you to disconnect the instrument before cleaning it. VA d W L 2 ! h var I al • PF dmd r H r31 Asy LN r02 V L2 r17 var L1 r32 Asy LL r03 V L3 r18 var L2 r33 A L1 dmd r04 V L1-2 r19 var L3 r34 A L2 dmd r20 Ph seq r35 A L3 dmd A M r06 V L3-1 r21 PF L1 r36 W L1 dmd r07 A L1 r22 PF L2 r37 W L2 dmd r08 A L2 r23 PF L3 r38 W L3 dmd r09 A L3 r24 V LN sys r39 VA L1 dmd r10 A n r25 V LL sys r40 VA L2 dmd r11 W L1 r26 W sys r41 VA L3 dmd al r12 W L2 r27 VA sys r42 W sys dmd PF dmd r13 W L3 r28 var sys r43 VA sys dmd r14 VA L1 r29 PF sys r15 VA L2 r30 Hz var Hz fig. 20 fig. 19 ▲ 2 • V k A M ▲ W var Hz al PF dmd MIN: V, A(•) L 2 k A M - L 1 ▲ W var Hz VAr d.P.o tYP dP Lo.S HI.S dEL Fun out k A M L 1 L 2 al PF dmd PF 1 - PF 2 - PF 3 - MIN ▲ W var Hz ■ PRECAUZIONI DI SICUREZZA Leggere attentamente il manuale di istruzioni. Qualora l’apparecchio venisse adoperato in un modo non specificato dal costruttore, la protezione prevista dall’apparecchio potrebbe essere compromessa. Manutenzione: Per mantenere pulito lo strumento usare un panno inumidito; non usare abrasivi o solventi. Si consiglia di scollegare lo strumento prima di eseguire la pulizia. ! L 2 8 al L 3 VA dmd MAX, W dmd MAX k A M ■ SICHERHEITSMAßNAHMEN Die Betriebsanleitung aufmerksam lesen. Sollte das Gerät nicht gemäß der Herstellerangaben verwendet werden, könnte der vom Gerät vorgesehene Schutz beeinträchtigt werden. Wartung: Das Gerät mit einem feuchten Tuch reinigen; keine Scheuer- oder Lösemittel verwenden. Das Gerät vor der Reinigung ausschalten. ! fig. 24 L 1 ▲ W L 2 var Hz al • V k A M L 3 L 1 VA ▲ W var Hz L 2 k A M • La variable mesurée clignote indiquant l’activation d’une alarme (voir figure “G” à gauche: VL1, 200V). Une ou plusieurs alarmes peuvent être connectées à la même variable, la première condition d’alarme fait clignoter la gamme de la variable. L’activation d’une des deux sorties (relais ou collecteur ouvert) est indiqué par le diode “al” (•) s’elles sont sélectionnées comme alarme. ■ MENU AJUSTE DE ALARMA A.O1 : “oFF” desactiva la alarma A.01, y continua a la alarma siguente (hasta A 16). Todos los ajustes seleccionados anteriormente permanecen en memoria. “on” permite la habilitación de la alarma, después seleccionar la variable que debe ser controlada: VAr : seleccionar la variable que debe ser controlada (ver tabla “I”). no, para ajustar directamente la alarma siguente. YES, para continuar la programación de todos los parámetros conectados a la alarma seleccionada: d.P.o : desactivar la alarma al arranque, “no” para desactivar la función o “YES” para activarla. tYP : selecciona el tipo de alarma: de máximo (uP) o de mínimo (do) alarma dentro de banda (in), alarma fuera de banda (out). dP : selección de la posición del punto decimal. Lo.S : selección del limite mínimo. Hi.S : selección del limite máximo. dEL : selección del retardo a la conexión (0 a 255 s). Fun : selección de la función de OR o AND (ver tabla “AND/OR” abajo). out : selección del relé que debe ser activado en caso de alarma “rl 1” salida relé 1 o “rl.2” salida relé 2. NOTAS IMPORTANTES: • La variable medida parpadea en relación a una alarma (ver figura “G” a la izquierda: V L1, 200V). Es posible conectar mas de una alarma a la misma variable, el campo variable parpadea en relación a la primera alarma. El LED “al” (•) indica la activación de una de las dos salidas (relé o a colector abierto) si son seleccionadas como alarma. • Si las dos salidas digitales (relé o a colector abierto) están instaladas en el equipo es posible la gestión de hasta 16 alarmas que pueden ser conectadas a la salida 1 y/o 2. • Si “var” o “W” son negativos, el punto decimal a la derecha parpadea en correspondencia a la variable negativa (ver figura “H” a la izquierda). • Si el equipo indica una potencia negativa, la energía correspondiente no será calculada. • Quand les deux sorties (relais ou collecteur ouvert) sont installées dans l’appareil, on peut gérer jusqu’à 16 alarmes que peuvent être connectées à la sortie 1 et/ou 2. • Si “var” ou “W sont négatives, le point décimal à droite clignote en correspondance avec la variable négative (voir figure “H” à gauche. • Si l’appareil affiche une puissance négative, l'énergie correspondante ne serait pas considerée. ■ MESURES DE SECURITE Lire attentivement le manuel de l’utilisateur. Si l’appareil est utilisé dans des conditions differentes de celles spécifiées par le fabricant, le niveau de protection prévu par l’instrument peut être compromis. Entretien: Pour nettoyer l’instrument, utiliser un chiffon humide; ne pas utiliser d’abrasifs ou de solvants. Il faut déconnecter le dispositif avant de procéder au nettoyage. ■ NORMAS DE SEGURIDAD Leer el manual y seguir atentamente las instrucciones. Si se utiliza el equipo de manera distinta de como indica el fabricante se puede dañar la protección de la que esta provisto el instrumento. Mantenimiento: para tener el instrumento limpio, limpiar periódicamente la carcasa con un trapo un poco humedecido. No utilizar productos abrasivos o disolventes. Desconectar el instrumento antes de limpiarlo. ! L 1 al L 3 ▲ W var Hz al PF dmd h: 49 672.95 fig. 26 V k A M L 1 VA h PF dmd THD: V, A(•) fig. 25 V VA h PF dmd A dmd MAX REMARQUES IMPORTANTES: ■ MENU RÉGLAGE ALARME A.O1 : “oFF” désactivation de l’alarme A.01, en passant à l’alarme suivante (jusqu’à A 16). Tous les autres réglages restent mémorisés. “on”: activation de l’alarme, puis sélectionner la variable à contrôler: VAr : sélectionner la variable à contrôler (voir table “ I”). no, pour aller directement au réglage du prochaine alarme. YES, pour continuer la programmation de tous les autres paramètres concernant l’alarme sélectionné: d.P.o : desactiver l’alarme à l’allumage, “no” pour desactiver la fonction ou “YES” pour l’activer. tYP : sélectionner le type d’alarme: haute (uP) ou basse (do), alarme dans fenêtre (in), alarme fenêtre exterieure (out). dP : sélection de la position du point décimal. Lo.S : sélection valeur du point de consigne basse. Hi.S : sélection valeur point de consigne haute. dEL : sélection sur temporisation activée de 0 à 255 sec. Fun : sélection fonction OR ou AND (voir la figure “OR/AND” dessous). out : sélection du relais à activer en cas d’alarme Sortie relais 1 “rl.1”. Sortie relais 2 “rl.2” . ou.1 / ou.2 : ajuste salida 1 / 2, selección: EnE : retransmisión del valor de la energía activa “Act” o reactiva “reA” mediante pulsos. “dP” selecciona el punto decimal. “PuL” selecciona el numero de pulsos para kWh/kvarh de 0,01 a 500. ALr : activa la salida de alarma. “nd” selecciona el relé normalmente desactivado o normalmente activado “nE”. rEn : activa el control remoto (mediante conexión en serie) de la salida 1/2. ! OR fig. 23 V h PF dmd WICHTIGE HINWEISE: • Die gemessene Größe blinkt, wenn ein Alarm aktiviert ist (siehe Abb. “G” links: VL1, 200V). Es ist möglich mehr als einen Alarm mit der selben Größe verbinden; wenn der erste Alarm aktiviert ist, blinkt der Bereich der Größe. Die “al” (•) LED bedeutet die Aktivierung von einem der zwei Ausgänge (Relais oder offener Kollektor Ausgang). • Wenn beide digital Ausgänge im Gerät vorhanden sind (Relais oder offener Kollektor), ist es möglich bis zu 16 Alarme zu kontrollieren; die 16 Alarme können zu Ausgang 1 und/oder Ausgang 2 verbunden sein. • Wenn “var” oder “W negative sind, blinkt der Dezimal punkt Äußerst Rechts, entsprechend der negativen Größe (siehe Abb. “H” links). • Sollte negative Energie angezeigt werden, ist zu beachten, dass diese nicht gezählt wird. ■ AJUSTE OUT 1 / OUT2 A.01... A.16. VA h L 3 NOTE IMPORTANTI: • La variabile misurata lampeggia se si trova in stato di allarme (vedi figura “G” a sinistra: V L1, 200V). E’ possibile abbinare più allarmi alla stessa variabile, la prima condizione di allarme che si verificherà determinerà il lampeggio del campo variabile. La spia “al” (•) indica l’attivazione di una delle due uscite (relè o a collettore aperto) nel caso siano selezionate come allarme. • Qualora lo strumento abbia installato le due uscite digitali (relè o a collettore aperto) è possibile gestire fino a 16 allarmi che possono essere abbinati all’uscita 1 e/o uscita 2. • Se “var” o “W” sono negativi il punto decimale all’estrema destra lampeggia in corrispondenza della variabile negativa (vedi figura “H” a sinistra). • Qualora lo strumento visualizzi una potenza negativa , l’energia relativa non verrà in alcun modo conteggiata. FRANÇAIS ■ RÉGLAGE OUT 1 / OUT2 ou.1 / ou.2 : réglage sorties 1 / 2, sélectionner: EnE : retransmission de la valeur de l'énergie active “Act” ou réactive “rEA” par impulsions. “dP” pour sélectionner le point décimal. “PuL” pour sélectionner le nombre d’impulsions par kWh/kvarh de 0,01 à 500. ALr : activation de la sortie d’alarme. “nd” sélection du relais normalement ouvert ou le relais normalement fermé “nE”. rEn : activation du contrôle à distance (par connexion série) de la sortie 1-2. AND fig. 22 V VA h L 3 AND/OR fig. 21 V VA VA h L 3 L 1 ▲ L 1 L 2 Var r16 VA L3 r05 V L2-3 h ▲ r r01 V L1 k W L 3 Var V VA L 2 r ▲ L 1 Var ▲ Hz ▲ L 3 ■ ALARM SETUP MENU A.O1 : “oFF” disabilita l’allarme A.01, passando all’allarme successivo (fino a A.16). Le eventuali impostazioni selezionate precedentemente rimangono memorizzate. “on” abilita l’allarme, quindi selezionare la variabile da controllare: VAr : scegliere la variabile da controllare (vedi tabella “I”). no, per passare direttamente alle impostazioni dell’allarme successivo YES, per continuare la programmazione di tutti i parametri relativa all’allarme in questione: d.P.o : disattivazione dell’allarme all’accensione, “no” per disattivare la funzione o “YES” per attivarla. tYP : seleziona il tipo di allarme: in salita (uP) o in discesa (do) a finestra interno (in) a finestra esterno (out). dP : seleziona la posizione del punto decimale. Lo.S : seleziona il valore della soglia inferiore. Hi.S : seleziona il valore della soglia superiore. dEL : seleziona il tempo di ritardo all’attivazione da 0 a 255 secondi. Fun : seleziona la funzione di OR o di AND (vedere riquadro in basso“AND/OR”). out : seleziona il relè da attivare in caso di allarme “rl.1” uscita relè 1 o “rl.2” uscita relè 2. ▲ S ESPAÑOL DEUTSCH ■ EINSTELLUNG OUT 1 / OUT2 ou.1 / ou.2 : Einstellung Ausgang 1 / 2, wählen: EnE : nochmalige Übertragung des Wertes der Wirkenergie “Act” oder der Blindenergie “rEA” über Impulse. “dP” Wahl des Dezimalpunkts “PuL” Wahl der Anzahl von Impulse bei kWh/kvarh von 0,01 bis 500. ALr : Alarm-Ausgang Aktivierung. “nd” Wahl des Relaisstatus: normal unerregt oder normal erregt “nE”. rEn : Aktivierung des Fernkontrolle (über serielle Schnittstelle) des 1 / 2 Ausgang. ■ EINSTELLUNG ALARM MENU A.O1 : “oFF” Deaktivierung des Alarms A.01, und weiter zu den nächsten (bis zu A 16). Alle andere Einstellungen bleiben gespeichert. “on” Aktivierung des Alarms und Wahl der zukontrollierenden Größe: VAr: Wahl der zu kontrollierenden Größe (siehe Tab. “ I”). no, direkt zur Einstellung des nächsten Alarmes gehen YES, alle weiteren Parameter des eingestellten Alarmes programmieren. d.P.o : Desaktivierung des Alarms bei Einschaltung, “no” um diese Funktion zu deaktivieren oder “YES” um die Funktion zu Aktivieren. tYP : Wahl des Typs des Alarms: Höchstwert des Alarms (uP) oder Mindestwert des Alarms (do), int. Fensteralarm (in), ext. Fensteralarm (out). dP : Wahl der Position des Dezimalpunkts. Lo.S : Wahl der Mindestschwellengrenze Hi.S : Wahl der Hochstschwellengrenze dEL : Wahl Alarm-Einschaltverzögerung von 0 bis 255 Sek. Fun: Wahl der OR oder AND Funktion (siehe die “OR/AND” Abbildung hier unten) . out : Wahl ob Relais normal unerregt. “rl.1” Relaisausgang 1 oder “rl.2” Relaisausgang 2. L 2 ▲ S S S ITALIANO ■ SETUP OUT 1 / OUT2 ou.1 / ou.2 : setup uscita 1 / 2, selezionare: EnE : ritrasmette il valore dell’energia attiva “Act” o reattiva “rEA” mediante impulsi. “dP” seleziona il punto decimale. “PuL” seleziona il numero di impulsi per kWh/kvarh che si desidera generare da 0,01 a 500. ALr : attiva l’uscita allarme. “nd” seleziona il relè normalmente diseccitato o normalmente eccitato “nE”. rEn : attiva il controllo remoto (mediante connessione seriale) dell’uscita 1/2. ▲ W h L 3 var Hz fig. 27 V k A M L 1 VA L 2 ▲ S ■ SETUP OUT 1 / OUT2 ou.1 / ou.2 : setup of output 1 / 2, select: EnE : retransmits the value of the active energy “Act” or the reactive one “rEA” by means of pulses. “dP” selects the decimal point. “PuL” selects the number of pulses per kWh/kvarh from 0,01 to 500. ALr : enables the alarm output. “nd” selects the normally disabled relay or the normally enabled one “nE”. rEn : activates the remote control (by means of serial connection) of the 1 / 2 output. al PF dmd kvarh: 556.5 partial meter ▲ W h L 3 var Hz fig. 28 V k A M L 1 VA L 2 ▲ S ENGLISH c ALARM SETUP MENU al PF dmd kWh: 6 574.8 partial meter ▲ W h L 3 var Hz V k A M VA L 2 ▲ ab SETUP OUT 2 al PF dmd kvar: 3 553 944.9 total m. ▲ W ▲ SETUP OUT 1 h L 3 var Hz al PF dmd kWh: 15 933 453.7 total m. 1 Carlo Gavazzi Controls SpA, Via Safforze, 8 - 32100 Belluno (Italy) Tel. +39 0437 931000, Fax +39 0437 931021 CARLO GAVAZZI A u t o m a t i o n C o m p o n e n t s WM14DIN/96 A IM ML 261009 Cod. 8020697 WM14DIN A/WM1496 A Three Phase power analyser ENGLISH ■ SAFETY PRECAUTIONS Read carefully the instruction manual. If the instrument is used in a manner not specified by the producer, the protection provided by the instrument may be impaired. Maintenance: make sure that the connections are correctly carried out in order to avoid any malfunctioning or damage to the instrument. To keep the instrument clean, use a slightly damp cloth; do not use any abrasives or solvents. We recommend to disconnect the instrument before cleaning it. ! ■ TECHNICAL SPECIFICATIONS Rated inputs System type: 3 Current (Shunts), Voltage 4. Accuracy (@25°C ±5°C, R.H. ≤60%) (display, RS485) with CT=1 and VT=1; AV5: 1150W-VA-var, FS:230VLN, 400VLL; AV6: 285W-VA-var, FS:57VLN, 100VLL. Current 0.25 to 6A: ±(0.5% FS +1DGT). From 0.03A to 0.25A: ±(0.5% F.S.+7DGT). Neutral current from 0.25 to 6A: ±(1.5% FS +1DGT) from 0.09A to 0.25A: ±(1.5% F.S.+7DGT). Phase-phase voltage ±(1.5% FS +1 DGT). Phase-neutral voltage ±(0.5% FS + 1 DGT). Active and Apparent power, from 0.25 to 6A: ±(1% FS +1DGT); from 0.03A to 0.25A: ±(1% FS +5DGT). Reactive power from 0.25 to 6A: ±(2% FS +1DGT); from 0.03A to 0.25A: ±(2% FS +5DGT). Active energy Class 1 (Start up current: 30mA). Reactive energy Class 2 (Start up current: 30mA). Frequency ±0.1Hz (48 to 62Hz). Harmonic distortion ±3% F.S. (up to 15th harmonic) (F.S.: 100%). Additional errors: Humidity≤0.3% FS, 60% to 90% RH. Temperature drift: 200ppm/°C. Sampling rate: 1600 samples/s @ 50Hz, 1900 samples/s @ 60Hz. Display refresh time: 200ms (FFT off) 500ms (FFT on). Display: Type LED, digit height 14mm (96x96) or 9mm (DIN). Read-out for instant. var. 3x3 DGT Read-out for energies 3+3+3 DGT (Max indication: 999 999 99.9) Read-out for hour counter 1+3+3 DGT (Max. indication: h 9 999 9.99). Measurements: Current, voltage, power, power factor, frequency Type TRMS measurement of distorted waves. Coupling type Direct Crest factor < 3, max 10A peak. Input impedance: 380/660VL-L (AV5) 1.6 MΩ ±5%; 120/208VL-L (AV6) 1.6 MΩ ±5%; Current ≤ 0.02Ω Frequency: 48 to 62 Hz. Overload protection: (max values) Continuos voltage/current AV5: 460VLN/800VLL/6A; AV6: 145VLN/250VLL/6A. For 500ms: voltage/current AV5: 800VLN/1380VLL/36A; AV6: 240VLN/416VLL/36A. Pulse outputs: Number of outputs: up to 2. Programmable from 0.01 to 500 pulses per kWh/kvarh. Pulse duration ≥ 100ms <120msec (ON), ≥ 120msec (OFF) according to EN62053-31 Relay outputs: Number of outputs: up to 2, independent. Alarm modes: up alarm, down alarm, in window alarm, out window alarm, for all the mentioned models there is the function “start-up deactivation” available. All alarms can be connected to any one of the available variables (see the table “I”). Set-point adjustment from 0 to 100% of the displayed scale. Hysteresis: from 0 to full scale. On-time delay: 0 to 255s. Output status selectable: normally de-energized and normally energized. Min. response time ≤400ms, filters excluded with FFT off; 1s with FFT on and set-point on-time delay: “0 s”. Note: the 2 digital outputs can also work as one pulse output and one alarm output the 2 outputs can also be controlled through a remote control (RS485). Static outputs: Purpose for pulse outputs or for alarm outputs Signal VON 1.2 VDC/ max. 100 mA, VOFF 30 VDC max. Insulation by means of optocuplers, 4000 VRMS output to measuring inputs, 4000 VRMS output to power supply input. Relay outputs: Usage for alarm outputs or for pulse outputs. Relay type: SPST type AC 1-5A @ 250VAC; DC 12-5A @ 24VDC AC 15-1.5A @ 250VAC; DC 13-1.5A @ 24VDC. Mechanical life: ≥30x106 operations; Elctrical life: ≥105 operations (@ 5A, 250V, PF1). Insulation 4000VRMS output to measuring input, 4000 VRMS output to supply input. RS422/RS485 port: (on request) Multidrop bidirectional (static and dynamic variables). Connections: 2 or 4 wires, max. distance 1200m, termination directly on the instrument. Addresses from 1 to 255, key-pad selectable. Protocol MODBUS/JBUS (RTU). Data (bidirectional). Dynamic (reading only): system and phase variables. Static (writing only): all the configuration parameters. Data format: 1 start bit, 8 data bit, no parity,1 stop bit. Baud-rate 4800, 9600,19200, 38400bits/s. Insulation by means of optocouplers, 4000 VRMS output to measuring input 4000 VRMS output to supply input Auxiliary power supply: 90 to 260VAC/DC; 16 to 60VAC/DC. Power consumption: AC: 6 VA DC: 3.5W. Operating temperature: 0° to +50°C (32° to 122°F). (RH < 90% non condensing). Storage temperature: -10° to +60°C (14° to 140°F) (RH < 90% non condensing). Relative humidity (non condensing): <90%. Overvoltage: category Cat. III (IEC 60664, EN60664). Insulation: (for 1 minute) 4kVACRMS between measuring inputs and power supply. 4kVAC/DC @ I≤ 3mA between measuring inputs and RS485/RS232. 4kVAC RMS between power supply and RS485/RS232. Dielectric strength: 4kVACRMS (for 1 min). EMC: emissions, EN61000-6-3 residential environment, commerce and light industry Immunity, EN61000-6-2 industrial environment. Pulse voltage (1.2/50µs): EN61000-4-5. Safety standards: IEC60664, IEC61010-1EN60664, EN61010-1 Approvals: CE. Connections: 5(6) A screw-type Max cable cross sect. area 2.5 mm2 . Min/Max screws tightening torque: 0.4Nm/0.8Nm. Housing Dimensions: (WxHxD) 96 x 96 x 63 mm (panel version), IN / OUT Instruction Sheet Instrument Features 107.5x90x64.5 (DIN version) . Material ABS self-extinguishing: UL 94 V-0. Mounting: Panel (96), DIN-rail (DIN). Protection degree: front IP40 (DIN version), IP65 (96 version). Terminal blocks: IP20 (96 and DIN version). Weight: approx. 400 g (packing included). Additional technical features: environmental conditions: indoor use only, pollution degree 2, altitude up to 2000m. ■ SOFTWARE FUNCTIONS Password Numeric code of max. 3 digits; 2 protection levels of the programming data. 1st level: password “0”, no protection. 2nd level: password from 1 to 999, all data are protected System selection 3P = balanced 3-phase (1CT, 3 or 4 wires); 3P.n = unbalanced 3-phase with or without neutral (3 or 4 wires); 3P.I = balanced 3-phase (1CT, 2 wires); 3P.A = unbalaced 3-phase ARON connection (3 wires); 2P = 2-phase (3 wires); 1P = single phase (2 wires). Transformer ratio. CT 1 to 60000. VT/PT 1.0 to 6000.0 Filter. Operating range 0 to 100% of the displayed scale. Filtering coefficient 1 to 32. Filter action Measurements, alarms, serial output (fundamental variables: V, A, W and their derived ones). Displaying Up to 3 variables per page. Alarms working mode “OR” or “AND” or “OR+AND” functions (see OR/AND table). Freely programmable on up to 16 alarms. The alarms can be connected to any variables available in the “ I “ table. Reset. By means of keypad: all variables including instantaneous, min, max, dmd and counters variables. Max: A1, A2, A3, W1, W2, W3, Wdmd1-2-3, Wsys dmd, VAsys dmd; min: PF1, PF2, PF3; A1, A2, A3; V1, V2, V3; - dmd: A1, A2, A3, VA1, VA2, VA3, VAsys, W1, W2, W3, Wsys, A. All counters: total energies: kWh, kvarh; - partial energies: kWh, kvarh; - hour counter. Max and min. ITALIANO ■ NORME DI SICUREZZA Leggere attentamente il manuale istruzioni. Qualora l’apparecchio venisse adoperato in un modo non specificato dal costruttore, la protezione prevista dall’apparecchio potrebbe essere compromessa. Manutenzione: assicurarsi che i collegamenti siano effettuati correttamente al fine di evitare qualsiasi malfunzionamento o danneggiamento dello strumento. Per mantenere pulito lo strumento usare un panno leggermente inumidito; non usare abrasivi o solventi. Si consiglia di scollegare lo strumento prima di pulirlo. ! ■ CARATTERISTICHE TECNICHE Tipo di sistema ingressi nominali: 3 corrente (shunts), 4 tensione. Precisione: (@25°C ±5°C, R.H. ≤60%) (display, RS485) con TA =1 e TV=1; AV5: 1150W-VA-var, FS:230VLN, 400VLL; AV6: 285W-VA-var, FS:57VLN, 100VLL. Corrente: da 0.25 a 6A: ±(0.5% FS +1 DGT), da 0.03A a 0.25A: ±(0.5%F.S.+7DGT). Corrente di neutro da 0.25 a 6A: ±(1.5% FS +1DGT), da 0.09A a 0.25A: ±(1.5%FS+7DGT). Tensione concatenata: ±(1.5% FS +1 DGT). Tensione stellata: ±(0.5% FS + 1 DGT). Potenza attiva e apparente, da 0.25 a 6A: ±(1% FS +1DGT), da 0.03A a 0.25A: ±(1% FS +5DGT). Potenza reattiva da 0.25 a 6A: ±(2% FS +1DGT), da 0.03A a 0.25A: ±(2% FS +5DGT). Energia attiva classe 1 (corrente di avviamento: 30mA). Energia reattiva classe 2 (corrente di avviamento: 30mA). Frequenza ±0.1Hz (48 a 62Hz). Distorsione armonica ±3% F.S. (fino alla 15a armonica) (F.S.: 100%). Errori addizionali: Umidità: ≤0.3% FS, 60% a 90% U.R. Deriva termica: 200ppm/°C. Campionamento: 1600 campioni/s @ 50Hz, 1900 campioni/s @ 60Hz. Rinfresco display: 200ms (FFT off) 500ms (FFT on). Display: tipo a LED, altezza digit 14mm (96x96) o 9mm (DIN). Visualizzazione var. istantanee 3x3 DGT visualizzazione energie 3+3+3 DGT (Max indicazione: 999 999 99.9) Visualizzazione contaore 1+3+3 DGT (Max. indicazione: h 9 999 9.99). Misure: corrente, tensione, potenza, fattore di potenza, frequenza, TRMS di forme d’onda distorte. Accoppiamento: diretto. Fattore di cresta < 3, max picco 10A . Impedenza d’ingresso: 380/660VL-L (AV5) 1.6 MΩ ±5%; 120/208VLL (AV6) 1.6 MΩ ±5%; Corrente ≤ 0.02Ω Frequenza: 48 a 62 Hz. Protezione dai sovraccarichi: (valori massimi); continuativo: tensione/corrente, AV5: 460VLN/800VLL/6A; AV6: 145VLN/ 250VLL/6A. Per 500ms: tensione/corrente AV5: 800VLN/ 1380VLL/36A; AV6: 240VLN/416VLL/36A. Uscite impulsive: Numero di uscite: fino a 2. Programmabile da 0.01 a 500 impulsi per kWh/kvarh. Durata dell’impulso: ≥ 100ms <120msec (ON), ≥ 120msec (OFF) secondo EN62053-31 Uscite relè: numero di uscite: fino a 2, indipendenti. Tipo allarme: allarme di massima, allarme di minima, allarme finestra interna, allarme finestra esterna, per tutti i modelli menzionati è disponibile la funzione “disattivazione all’avviamento”. Tutti gli allarmi possono essere associati ad una qualsiasi delle variabili disponibili (vedi tabella “ I ”). Regolazione del set-point da 0 a 100% della scala visualizzata. Isteresi: da 0 al fondo scala. Ritardo all’attivazione: 0 a 255s. Stato dell’uscita: selezionabile: normalmente diseccitato e normalmente eccitato. Tempo min. di risposta: ≤400ms, filtri esclusi con FFT off; 1s con FFT on e ritardo attivazione soglia: “0 s”. Nota: le due uscite digitali possono anche lavorare come un’uscita impulsi e un’uscita allarmi. Le due uscite possono essere controllate tramite un controllo remoto (RS485). Uscite statiche: tipo di utilizzo: per uscite impulsi o uscite allarmi. Segnale VON 1.2 VCC/ max. 100 mA, VOFF 30 VCC max. Isolamento per mezzo di optoisolatori, uscita 4000 VRMS verso ingressi di misura, uscita 4000 VRMS verso ingresso alimentazione. Uscite relè: utilizzo per uscite di allarme o per uscite impulsi. Tipo di relè: tipo SPST AC 1-5A @ 250VCA; DC 12-5A @ 24VCC AC 15-1.5A @ 250VCA; DC 13-1.5A @ 24VCC. Vita meccanica: ≥30x106 commutazioni: vita elettrica: ≥105 commutazioni (@ 5A, 250V, cosϕ1)Isolamento 4000 VRMS uscita verso ingresso di misura, 4000 VRMS uscita verso ingresso di alimentazione. Porta RS422/RS485: (a richiesta) Multidrop bidirezionale (variabili statiche e dinamiche). Collegamenti: 2 o 4 fili, max. distanza 1200m, terminazione direttamente sullo strumento. Indirizzi da 1 a 255, selezionabile da tastiera. Protocollo MODBUS/JBUS (RTU). Dati (bidirezionale). Dinamico (solo lettura): variabili di sistema e di fase. Statico: (solo scrittura): tutti i parametri di configurazione. Formato dati: 1 bit di start, 8 bit di dati, nessuna parità,1 bit di stop. Baud-rate 4800, 9600,19200, 38400bits/s. Isolamento per mezzo di optoisolatori, 4000 VRMS uscita verso ingresso di misura 4000 VRMS uscita verso ingresso di alimentazione. Alimentazione ausiliaria: da 90 a 260VCA/CC; da 16 a 60VCA/CC.. Consumo energia: AC: 6 VA CC: 3.5W. Temperatura di funzionamento: da 0° a +50°C (da 32° a 122°F). (UR < 90% senza condensa). Temperatura di immagazzinaggio: -da -10° a +60°C (da 14° a 140°F) (UR < 90% senza condensa). Sovratensione: categoria Cat. III (IEC 60664, EN60664). Isolamento: (per 1 minuto) 4kVCARMS tra ingressi di misura e alimentazione. 4kVCA/CC @ I≤ 3mA tra ingressi di misura e RS485/RS232. 4kVCA RMS tra alimentazione e RS485/RS232. Rigidità dielettrica: 4kVCARMS (per 1 min). EMC: emissioni, EN61000-6-3 ambiente residenziale, commercio ed industria leggera; Immunità ambiente industriale EN61000-6-2. Tensione a impulsi (1.2/50µs): EN61000-4-5. Norme di sicurezza: IEC60664, IEC61010-1EN60664, EN61010-1 Approvazioni: CE. Collegamenti: 5(6) A a vite; Sezione max. cavo: 2.5 mm2 . Coppia min/max serraggio viti: 0,4Nm/0,8Nm. Custodia: Dimensioni (LxHxP) 96 x 96 x 63 mm (versione pannello), 107.5x90x64,5 (versione DIN). Materiale ABS autoestinguente: UL 94 V-0. Montaggio: pannello (96), guida DIN. Grado di protezione: frontale IP40 (versione DIN), IP65 (versione 96). Morsettiere: IP20 (versione 96 e DIN). Peso: circa 400 g (imballo incluso). ■ FUNZIONI SOFTWARE Password Codice numerico di max. 3 digits; 2 livelli di protezione dei dati di programmazione: 1° livello: password “0” , nessuna protezione; 2° livello: password da 1 a 999, tutti i dati sono protetti. Selezione sistema 3P = bilanciato trifase (1 TA, 3 o 4 fili); 3P.n = sbilanciato trifase con o senza neutro (3 o 4 fili); 3P.I = bilanciato trifase (1 TA, 2 fili); 3P.A = sbilanciato trifase collegamento ARON (3 fili); 2P = bifase (3 fili); 1P = singola fase (2 fili). Rapporto di trasformazione TA da 1 a 60000. TV da 1.0 a 6000.0 Filtro. Campo di funzionamento da 0 a 100% della scala visualizzata. Coefficiente di filtro da 1 a 32. Azione del filtro: Misure, allarmi, uscita seriale (variabili fondamentali: V, A, W e loro derivate). Visualizzazione fino a 3 variabili per pagina. Modo di funzionamento degli allarmi “OR” o “AND” o funzioni “OR+AND” (vedere tabella AND/OR). Liberamente programmabile fino a 16 allarmi. Gli allarmi possono essere associati a qualsiasi variabile disponibile nella tabella “ I “. Reset. Da tastiera: - tutte le variabili incluse le variabili istantanee, min, max. dmd e contatori. Max: A1, A2, A3, W1, W2, W3, Wdmd1-2-3, Wsys dmd, VAsys dmd; min: PF1, PF2, PF3; A1, A2, A3; V1, V2, V3; - dmd: A1, A2, A3, VA1, VA2, VA3, VAsys, W1, W2, W3, Wsys, A. Tutti i contatori: Energie totali: kWh, kvarh; - energie parziali: kWh, kvarh; - contaore - Max. e min. DEUTSCH ■ SICHERHEITSBESTIMMUNGEN Bitte lesen Sie sorgfälltig die Bedienungsanleitung. Bei von den Angaben des Herstellers abweichendem Gebrauch des Gerätes könnte der Schutz, mit dem das Gerät ausgestattet ist, beschädigt werden. Wartung: Sicherstellen, daß die Verbindungen korrekt sind, um falsche Arbeitsweise oder Beschädigung des Instruments zu vermeiden. Reinigen Sie das Gehäuse in regelmäßigen Zeitabständen mit einem Tuch und Reinigungsmittel. Verwenden Sie keine Kratzenden Reinigungsmittel oder Lösungsmittel. Schalten Sie das Gerät aus, bevor der Reinigung. ! ■ TECHNISCHE DATEN Nenneingänge Systemtyp: 3 Strom (Shunts), Spannung 4. Genauigkeit (@25°C ±5°C, R.L. ≤60%) (Anzeige, RS485) mit St.W.=1 und Sp.W.=1; AV5: 1150W-VA-var, BE:230VLN, 400VLL; AV6: 285W-VAvar, FS:57VLN, 100VLL. Strom 0.25 bis 6A: ±(0.5% BE +1 stellig). Von 0.03A bis 0.25A: ±(0.5% BE+7 stellig). Nulleiter Strom von 0.25 bis 6A: ±(1.5% BE +1 stellig), von 0.09A bis 0.25A: ±(1.5% BE+7 stellig). Phase-phase Spannung ±(1.5% BE +1 stellig). PhasenNeutral Spannung ±(0.5% BE + 1 stellig). Wirkleistung und Scheinleistung, von 0.25 bis 6A: ±(1% BE +1 stellig); von 0.03A bis 0.25A: ±(1% BE +5 stellig). Blindleistung von 0.25 bis 6A: ±(2% BE +1 stellig); von 0.03A bis 0.25A: ±(2% BE +5 stellig). Wirkenergie Klasse 1 (Startstrom: 30mA). Blindenergie Klasse 2 (Startstrom: 30mA). Frequenz: ±0.1Hz (48 bis 62Hz). Harmonische Verzerrung ±3% BE (bis zu 15te Harmonische) (BE.: 100%). Zusätliche Fehler: Feuchtigkeit ≤0.3% BE, 60% bis 90% rL.. Temperaturabweichung: 200ppm/°C. Abtastrate: 1600 Abtastungen/s @ 50Hz, 1900 Abtastungen/s @ 60Hz. Anzeigenerneuerungszeit: 200ms (FFT off) 500ms (FFT on). Anzeige: Typ LED, Segmente:14mm hoch (96x96) oder 9mm (DIN). Anzeige für Momentanwerte 3x3 DGT Anzeige für Energie 3+3+3 stellig (Max Anzeige: 999 999 99.9) Anzeige für Stundenzähler 1+3+3 stellig (Max .Anzeige: h 9 999 9.99). Messungen: Strom, Spannung, Leistung, Leistungsfaktor, Frequenz TRMS Messung von verzerrten Wellen. Kopplungsart Direkt Crestfaktor < 3, max 10A Spitze. Eingangsimpedanz: 380/660VL-L (AV5) 1.6 MΩ ±5%; 120/208VL-L (AV6) 1.6 MΩ ±5%; Strom ≤ 0.02Ω Frequenz: 48 bis 62 Hz. Überlastschutz: (Max. Werte) fortwährend Spannung/Strom AV5: 460VLN/800VLL/6A; AV6: 145VLN/250VLL/6A. Für 500ms: Spannung/Strom AV5: 800VLN/1380VLL/36A; AV6: 240VLN/416VLL/36A. Impulsausgangs: Anzahl der Ausgänge: bis zu 2. Programmierbar von 0.01 bis 500 Impulse pro kWh/kvarh. Impulsdauer ≥ 100ms <120msec (ON), ≥ 120msec (OFF) nach EN62053-31 Relaisausgangs: Anzahl der Ausgänge: bis 2, unabhängig. Alarm Betriebsarten: Aufwärtsalarm, Abwärtsalarm, int. Fenster-Alarm, ext. Fenster Alarm, für alle diese Betriebsarten ist die Funktion “Start-up Deaktivierung” verfügbar. Alle die Alarme können verbunden mit allen verfügbaren Größen sein (siehe Tabelle “I”). Sollwert-einstellung von 0 bis 100% der angezeigte Skala. Hysteresis: von 0 bis volle Grösse. On-time Verzögerung: 0 bis 255 s. Ausgangsstatus wählbar; normal unerregt und normal erregt. Min. Ansprechszeit ≤400ms, ohne Filter, FFT off; 1 s FFT on. Verzögerung On-time Sollwert: “0 s” Zu beachten: Die 2 Digitalausgänge können auch als 1 ImpulsAusgang und 1 Alarm-Ausgang funktionieren. Die 2 Ausgänge können auch durch ein Fernsteurung kontrolliert werden (RS485). Statische Ausgänge: Zweck: für Impulsausgänge oder für Alarmausgänge. Signal VON 1.2VDC/max.100 mA, VOFF 30VDC max. Isolation durch Optokoppler 4000 VRMS Ausgang zu Messeingängen, 4000 VRMS Ausgang zu Stromversorgungseingang. Relaisausgänge: Zweck für Alarmausgänge oder für Impulsausgänge. Relaistyp: SPST AC 1-5A @ 250VAC; DC 12-5A @ 24VDC AC 151.5A @ 250VAC; DC 13-1.5A @ 24VDC. Mechanische Lebensdauer: ≥30x106 Schaltspiele; elektrische Lebensdauer: ≥105 Schaltspiele (@ 5A, 250V, PF1). Isolation: 4000VRMS Ausgang zu Messeingang, 4000VRMS Ausgang zu Strom-versorgungseingang. RS422/RS485: (auf Anfrage) Multidrop bidirektional (statische und dynamische Variablen). Anschlüsse: 2 oder 4 Leiter, max. Länge 1200m, Anschluss direkt am Gerät. Adressen: von 1 bis 255, über Tastatur wählbar. Protokoll: MODBUS/JBUS (RTU). Daten (bidirektional). Dynamisch (nur lesen): System und Phasenvariablen. Statisch (nur Schreiben): Alle Konfigurationsparameter. Datenformat: 1 Start bit, 8 Datenbit, keine Parit,1 Stopbit. Baud-Rate 4800, 9600,19200, 38400 bits/s. Isolation durch Optokoppler, 4000 VRMS Ausgang zu Messeingang. 4000 VRMS Ausgang zu Stromversorgung. Hilfstromversorgung: 90 bis 260VAC/DC; 16 bis 60VAC/DC. Stromverbrauch: AC: 6 VA DC: 3.5W. Betriebstemperatur: 0° bis +50°C (32° bis 122°F). (rL. < 90% nicht kondensierend). Lagertemperatur: -10° bis +60°C (14° bis 140°F) (rL < 90% nicht kondensierend). Überspannungs-Kategorie: Kat. III (IEC 60664, EN60664). Isolation: (1 Minute) 4kVAC RMS zwischen Messeingängen und Stromversorgung. 4kVAC/DC @ I≤ 3mA zwischen Messeingängen und RS485/RS232. 4kVAC RMS zwischen Stromversorgung und RS485/RS232. Dielektrische Stärke: 4kVACRMS (1 Min). EMC: Emissionen, EN61000-6-3 Wohnungumgebung, Handel und Leichtindustrie, Immunität EN61000-6-2 Industrieumgebung. Impulsspannung (1.2/50µs): EN61000-4-5. Sicherheitsnormen: IEC60664, IEC61010-1EN60664, EN61010-1 Genehmigungen: CE. Anschlüsse: 5(6) A Schraubbefestigung Max Kabelquerschnittfläche 2.5 mm2. Anzugsmoment: 0.4Nm/0.8Nm. Gehäuse: (WxHxD) 96 x 96 x 63 mm (Tafel Montage), 107.5x90x64.5 (DIN-Schiene) . Material ABS selbstlöschend: UL 94 V-0. Montage: Tafel (96), DIN-schiene (DIN). Schutzart: Front IP40 (DIN-schiene), IP65 (96 Typ). Klemme: IP20 (96 und DIN). Gewicht: ungefähr 400 g (einschl. Verp.) ■ SOFTWAREFUNKTIONEN Passwort Zahlenkode mit maximal 3 Stellen; 2 Schutzebenen für die Progammdaten: 1 Ebene: Passwort “0”, kein Schutz. 2te Ebene; Passwort von 1 bis 999, alle Daten werden geschützt. Systemartwahl 3P = symmetriche Last 3-Phasig (1St.W., 3 oder 4 Leiter); 3P.n = unsymmetriche Last 3-Phasig mit oder ohne Nulleiter (3 oder 4 Leiter); 3P.I = symmetriche Last 3-Phasig (1St.W., 2 Leiter); 3P.A = unsymmetriche Last 3-Phasig ARON Anschluss (3 Leiter); 2P = 2-Phasig (3 Leiter); 1P = 1 Phasig (2 Leiter). Wandlersverhältnis. St.W.1 bis 60000. Sp.W. 1.0 bis 6000.0 Filter. Funktionsbereich 0 bis 100% der angezeigte Skala. Filterkoeffizient 1 bis 32. Filterwirkung: Messungen, Alarme, serieller Ausgang (Grundvariablen: V, A, W und ihre Ableitungen). Anzeige Bis zu 3 Größe bei jeder Seite. Alarme Funktionsart “OR” oder “AND” oder “OR+AND” Funktionen (siehe “AND/OR” Tabelle). Frei programmierbar auf bis zu 16 Alarme. Die Alarme können mit allen in der Tabelle “ I “ anschliessbaren Variablen angeführten werden. Rücksetzen. Mittels Tastatur: Alle Variablen einschließlich momentane, min., max., dmd, und Zählervariablen. Max: A1, A2, A3, W1, W2, W3, Wdmd1-2-3, Wsys dmd, VAsys dmd; min: PF1, PF2, PF3; A1, A2, A3; V1, V2, V3; - dmd: A1, A2, A3, VA1, VA2, VA3, VAsys, W1, W2, W3, Wsys, A. Alle Zähler. Gesamtenergien: kWh, kvarh; - Teilenergien: kWh, kvarh; - Stundenzähler. Max. und Min. FRANÇAIS ■ NORMES DE SECURITE’ Lisez le mode d’emploi et respectez scrupuleusement les instructions. Si on utilise l’instrument autrement que de la manière indiquée par le producteur, on peut endommager les protections dont l’instrument est doté. Maintenance: s’assurer que les câblages sont bien connectés pour eviter tout malfonctionnement ou dommage de l’appareil. Nettoyer périodiquement l’étui avec un linge une peu humide; ne pas utiliser d’abrasifs, ni de solvants. Déconnecter l’appareil avant de le nettoyer. ! ■ CARACTERISTIQUES D’ENTREE Type système entrées nominales: 3 courant (Shunts), Tension 4. Précision (@25°C ±5°C, H.R. ≤60%) (Affichage, RS485) avec TC=1 et TT=1; AV5: 1150W-VA-var, FS:230VLN, 400VLL; AV6: 285W-VA-var, FS:57VLN, 100VLL. Courant 0.25 à 6A: ±(0.5% PE +1DGT). De 0.03A à 0.25A: ±(0.5% PE+7 DGT). Courant de neutre 0.25 à 6A: ±(1.5% PE +1DGT), de 0.09A à 0.25A: ±(1.5% PE+7 DGT). Tension phase-phase ±(1.5% PE +1 DGT). Tension phase-neutre ±(0.5% PE + 1 DGT). Puissance active et apparent, de 0.25 à 6A: ±(1% PE +1 DGT); de 0.03A à 0.25A: ±(1% PE +5DGT). Puissance réactive 0.25 à 6A: ±(2%PE +1DGT); de 0.03A à 0.25A: ±(2% PE +5DGT). Energie active, classe 1 (Courant de démarrage: 30mA). Energie réactive, classe 2 (Courant de démarrage: 30mA). Fréquence ±0.1Hz (48 à 62Hz). Distorsion harmonique ±3% PE (jusqu’à la 15ème harmonique) (PE: 100%). Erreurs additionnelles: Humidité≤0.3% PE, 60% à 90% HR Dérive de température: 200ppm/°C. Taux d’échantillonnage: 1600 échantillonnages/s @ 50Hz, 1900 échantillonnages/s @ 60Hz. Temps de refraîchissement: 200ms (FFT off) 500ms (FFT on). Afficheur: Type LED, hauteur chiffres 14mm (96x96) ou 9mm (DIN). Lecture des var. instantanées. 3x3 DGT Lecture des énergies 3+3+3 DGT (Indicat. max.: 999 999 99.9) Lecture compteur d’heures 1+3+3 DGT (Max. indication: h 9 999 9.99). Mesures: courant, tension, puissance, facteur de puissance, fréquence. Méthode de mesure: Mesure de valeur efficace vraie de formes d’ondes distordues. Type de couplage: direct. Facteur de crête. < 3, max 10A crête. Impédance d’entrée: 380/660VL-L (AV5) 1.6 MΩ ±5%; 120/208VL-L (AV6) 1.6 MΩ ±5%; Courant ≤ 0.02Ω Fréquence: 48 à 62 Hz. Protection contre les surcharges: (valeur max.) Tension/courant continu AV5: 460VLN/800VLL/6A; AV6: 145VLN/250VLL/6A. Pour 500ms: tension/courant AV5: 800VLN/1380VLL/36A; AV6: 240VLN/416VLL/36A. Sorties impulsions: Nombre de sorties: jusqu’à 2. Programmable de 0.01 à 500 impulsions pour kWh/kvarh. Durée d’impulsions ≥100ms <120msec (ON), ≥120msec (OFF) suivant EN62053-31. Sorties relais: Nombre de sorties: jusqu’à 2, indépendantes. Modes d’alarme: alarme haute, alarme basse, alarme basse avec désactivation au démarrage, alarme dans fenêtre, alarme fenêtre extérieure, pour tous ces modes d’alarme, la fonction “désactivation au démarrage est disponible. Tous les alarmes peuvent être connectés à n’importe quel variable disponible (voir la table “I”). Régulation du point de consigne de 0 à 100% de l’échelle affichée. Hystérésis: de 0 à pleine d’échelle. Temporisation activée: de 0 à 255 s. Etat sortie: sélectionnable; normalement déactivé, normalement activé. Temps de réponse min.: ≤400ms, filtres exclus avec FFT off; 1 s avec FFT on et point de consigne sur temporisation activée: “0 s”. Remarque: les 2 sorties numériques peuvent aussi fonctionner comme une sortie impulsion et une sortie alarme; Les deux sorties peuvent être controlées par un contrôle remote (RS485). Sorties statiques: type d’emploi: pour sortie impulsions ou pour sorties alarme. Signal VON 1.2 VCC/ max. 100 mA, VOFF 30 VCC max. Isolation au moyen de photocoupleurs; 4000 VRMS de la sortie sur entrées de mesure, 4000 VRMS de la sortie à l’entrée d’alimentation. Sorties relais: emploi pour sorties alarmes ou sorties impulsions. Type de relais: SPST, AC 1-5A @ 250VCA; DC 12-5A @ 24VCC AC 15-1.5A @ 250VCA; DC 13-1.5A @ 24VCC. Vie mécanique: ≥30x106 exécutions; vie électrique: ≥105 exécutions (@ 5A, 250V, PF1). Isolation au moyen de photocoupleurs, 4000 VRMS de la sortie sur entrée de mesure, 4000VRMS de la sortie à l’entrée alimentation. RS422/RS485: (sur demande) Multidrop bidirectionnel (variables statiques et dynamiques). Connexions: 2 ou 4 fils, distance max. 1200m, terminaison directement sur l’appareil. Addresses: de 1 à 255, selectable par clavier. Protocole MODBUS/JBUS (RTU). Données (bi-directionnelles). Dynamique (lecture seulement): variables système et phase. Statique (écriture seulement). Tous les paramètres de configuration. Format données: 1 bit de départ, 8 bits der données, aucune parité, 1 bit d’arrêt. Débit baud 4800, 4800, 9600,19200, 38400 bits/s. Isolation: au moyen de photocoupleurs, 4000 VRMS entre sortie et entrée de mesure; 4000 VRMS entre sortie et entrée alimentation. Alimentation électrique auxiliaire: 90 à 260VCA/CC; 16 à 60VCA/CC. Puissance consummée: AC: 6 VA CC: 3.5W . Température de fonctionnement: 0° à +50°C (32° à 122°F). (HR < 90% sans condensation). Température de stockage: -10° à +60°C (14° à 140°F) (HR < 90% sans condensation). Catégorie surtension: Cat. III (IEC 60664, EN60664). Isolation: (pendant 1 minute) 4kVCARMS entre entrées de mesure et alimentation. 4kVCA/CC @ I≤ 3mA entre entrées de mesure et RS485/RS232. 4kVCA RMS entre alimentation et RS485/RS232. Puissance diélectrique: 4kVACRMS (pour 1 min). EMC: emissions, EN61000-6-3 environnement résidentiel, commerce et industrie légère, EN61000-6-2 environnement industriel. Tension impulsionnelle (1.2/50µs): EN61000-4-5. Normes de sécurité: IEC60664, IEC61010-1EN60664, EN61010-1 Conformités: CE. Connexions: 5(6) A type à vis. Zone section trans. câble max. 2.5 mm2. Min/Max couple de serrage: 0.4Nm/0.8Nm. Boîtier: (WxHxD) 96 x 96 x 63 mm (version tableau), 107.5x90x64.5 (version DIN). Matériel ABS auto-extinguible: UL 94 V-0. Montage: tableau (96), rail DN (DIN). Degré de protection: front IP40 (version DIN), IP65 (version 96). Borne a vis: IP20 (version 96 et DIN). Poids: approx. 400 g (emballage inclu). ■ FONCTIONS LOGICIELS Mot de Passe Code numérique à max. 3 digits; 2 niveaux de protection des données de programmation: Niveau 1: mot de passe “0”, pas de protection; Niveau 2: mot de passe de 1 à 999, toutes les données sont protégées. Sélection du système 3P = équilibré triphasé (1TC, 3 ou 4 fils); 3P.n = non équilibré triphasé avec ou sans neutre (3 ou 4 fils); 3P.I = équilibré triphasé (1TC, 2 fils); 3P.A = non équilibré triphasé connexion ARON (3 fils); 2P = biphasé (3 fils); 1P = monophasé (2 fils). Rapport transformateur. TC 1 à 60000. TT 1.0 à 6000.0 Filtre. Gamme fonctionnement 0 à 100% de l’échelle affichée. Coefficient de filtrage 1 à 32. Action filtre: mesures, alarmes, sortie série (variables fondamentales: V, A, W et leurs dérivées). Affichage Jusqu’à 3 variables per page. Mode de fonctionnement alarmes: fonctions “OR” ou “AND” ou “OR+AND” (voir tableau “AND/OR”). Programmable librement jusqu’à 16 alarmes. Les alarmes peuvent être connectées à n’importe quelles variables disponibles dans le tableau “ I ”. Réinitialiser. Par clavier: toutes les variables y compris celles instantanées, min, max, dmd et variables compteurs. Max: A1, A2, A3, W1, W2, W3, Wdmd1-2-3, Wsys dmd, VAsys dmd; min: PF1, PF2, PF3; A1, A2, A3; V1, V2, V3; - dmd: A1, A2, A3, VA1, VA2, VA3, VAsys, W1, W2, W3, Wsys, A. Tous les compteurs. Energies totales: kWh, kvarh; - énergies par- tielles: kWh, kvarh; - compteurs horaire. Max et min. ESPAÑOL ■ NORMAS DE SEGURIDAD Leer el manual y seguir atentamente las instrucciones. Si se utiliza el equipo de manera distinta de como indica el Fabricante, se puede dañar la protección de la que está provisto el instrumento. Mantenimiento: Asegurarse de que las conexiones son correctas para evitar un mal funcionamiento o daños en el instrumento. Para tener el instrumento limpio, limpiar periódicamente la carcasa con un trapo un poco humedecido. No utilizar productos abrasivos o disolventes. Desconectar el equipo antes de limpiarlo. ! ■ ESPECIFICACIONES TÉCNICAS Entradas nominal, tipo de sistema: 3 Intensidad (Shunts), tensión 4. Précision (@25°C ±5°C, R.H. ≤60%) (display, RS485) con TC=1 y TT=1; AV5: 1150W-VA-var, FS:230VLN, 400VLL; AV6: 285W-VA-var, FS:57VLN, 100VLL. Intensidad 0.25 a 6A: ±(0.5% f.e. +1díg). De 0.03A a 0.25A: ±(0.5% f.e.+7 díg). Intensidad de neutro 0,25 a 6A: ±(1.5% f.e.+1díg) de 0.09A a 0.25A: ±(1.5% f.e.+7díg). Tension fase-fase ±(1.5% f.e.+1 díg). Tension fase-neutro ± (0.5% f.e. + 1 díg). Potencia activa y aparente, de 0.25 a 6A: ± (1% f.e. +1 díg); de 0.03A a 0.25A: ±(1% f.e. +5díg). Potencia reactiva de 0.25 a 6A: ±(2% f.e. +1díg), de 0.03A a 0.25A: ±(2% f.e. +5díg). Energia activa clase 1 (Intensidad de arranque: 30mA). Energia reactiva clase 2 (Intensidad de arranque: 30mA). Frecuencia ±0.1Hz (de 48 a 62Hz). Distorsión armónica ±3% f.e. (hasta el armónico 15°) (f.e.: 100%). Errores adicionales: humedad ≤0.3% f.e, de 60% a 90% HR. Deriva térmica: 200ppm/°C. Frecuencia de muestreo: 1600 lecturas/s @ 50Hz, 1900 lecturas/s @ 60Hz. Tiempo refresco display: 200ms (FFT off) 500ms (FFT on). Display: tipo LED, dígito 14mm (96x96) o 9mm (DIN). Lectura para variables instant. 3x3 DGT Lectura para energías 3+3+3 díg (Indicación max: 999 999 99.9) Lectura para cuenta horas 1+3+3 DGT (Max. Indicación: h 9 999 9.99). Medidas: Intensidad, tensión, potencia, factor de potencia, frecuencia. Valor TRMS de tensión/intens. de ondas distorsionadas. Tipo de conexión: directa. Factor de cresta < 3, Pico max 10A . Impedancia de entrada: 380/660VL-L (AV5) 1.6 MΩ ±5%; 120/208VL-L (AV6) 1.6 MΩ ±5%; Intensidad:≤ 0.02Ω Frecuencia: da 48 a 62 Hz. Sobrecarga: (valores max.) tensión/intensidad permanente: AV5: 460VLN/800VLL/6A; AV6: 145VLN/250VLL/6A. Durante 500ms: tensión/intensidad AV5: 800VLN/1380VLL/36A; AV6: 240VLN/416VLL/36A. Salidas de pulso: Número de salidas: hasta 2. Programables de 0.01 a 500 pulsos por kWh/kvarh. Duración de pulso ≥ 100ms <120msec (ON), ≥120msec (OFF) según norma EN62053-31. Salidas de relé: Número de salidas: hasta 2, independiente. Modos de alarma: alarma de max, alarma de min., alarma dentro de banda, alarma fuera de banda, para todos estos modos está la función con inhibición a la conexión. Todas las alarmas pueden ser conectadas a cualquiera de las variables (ver tabla “ I”). Ajuste punto de consigna de 0 a 100% de la escala visualizada. Histéresis: de 0 a la escala completa. Retardo a la conexión: de 0 a 255s. Estado de salida seleccionable: normalmente desactivada y normalmente activada. Tiempo min. de respuesta: ≤400ms, filtros excluidos con FFT off; 1s con FFT on. Retardo conexión alarma: “0 s”. Nota: las 2 salidas digitales también pueden funcionar como una salida de pulso y una de alarma. Las 2 salidas pueden también ser controladas mediante un control remoto (RS485). Salidas estáticas: Proposito para salidas de alarma o para salidas de pulso. Señal VON 1.2VCC/ max. 100mA,VOFF 30VDC max. Aislamiento mediante optoacopladores, 4000VRMS entre salida y entradas de medida, 4000VRMS entre salida y entrada de alimentación. Salidas de relé: utilización para salidas de alarma o para salidas de pulso. Relé tipo SPST AC 1-5A @ 250VCA; DC 12-5A @ 24VCC AC 15-1.5A @ 250VCA; DC 13-1.5A @ 24VCC. Vida mecánica: ≥30x106 operaciones; Vida eléctrica:: ≥105 operaciones (@ 5A, 250V, PF1). Aislamiento 4000VRMS entre salida y entrada de medida, 4000 VRMS entre salida y entrada de alimentación. Puerto RS422/RS485: (opcional) Multiterminal bidireccional (variables estáticas y dinámicas). Conexiones: 2 o 4 hilos, max. distancia 1200m, con terminación directa en el instrumento. Dirección: de 1 a 255, seleccionable por teclado. Protocolo MODBUS/JBUS (RTU). Datos (bidireccionales). Dinámicos (solo lectura): variables del sistema y de fase. Estáticos (solo escritura): todos los parámetros de configuración Formato de datos: 1 bit de arranque, 8 bits de datos, sin paridad, 1 bit de parada. Velocidad en baudios: 4800, 9600,19200, 38400bits/s. Aislamiento: mediante optoacopladores, 4000 VRMS entre salida y entrada de medida 4000 VRMS entre salida y entrada de alimentación. Alimentación auxiliar: 90 a 260VCA/CC; 16 a 60VCA/CC.. Temperatura de funcionamiento: 0° a +50°C (32° a 122°F). (HR <90% sin condensación). Temperatura de almacenamiento -10° a +60°C (14° a 140°F) (HR < 90% sin condensación). Sobretensión: Cat. III (IEC 60664, EN60664). Aislamiento: (durante 1 minuto) 4kVCARMS entre entradas de medida y alimentación. 4kVCA/CC @ I ≤ 3mA entre entradas de medida y RS485/RS232. 4kVCA RMS entre alimentación y RS485/RS232. Rigidez dielectrica: 4kVCARMS (durante 1 min). EMC: emisiones, EN61000-6-3 entornos residenciales, comercio e industria ligera, EN61000-6-2 entornos industriales. Tensión de pulso (1.2/50µs): EN61000-4-5. Normas de seguridad: IEC60664, IEC61010-1EN60664, EN61010-1 Homologación: CE. Conexiones: 5(6) A tornillo. Sección máx. del cable 2.5 mm2.Par de apriete mín/máx: 0.4Nm/0.8Nm. Dimensiones de la caja: (WxHxD) 96 x 96 x 63 mm (versión panel), 107.5x90x64.5 (versión DIN). Material ABS autoexitinguible: UL 94 V-0. Montaje: Panel (96), carril DIN (DIN). Grado de protección: frontal IP40 (versión DIN), IP65 (versión 96). Bloque de terminales: IP20 (versión 96 y DIN). Peso: aprox. 400 g (embalaje incl.). ■ FUNCIONES DEL SOFTWARE Clave: Código numérico de 3 díg.; 2 niveles de protección de los datos de programación. 1er nivel: clave “0”, sin protección. 2do nivel: clave de 1 a 999, todos los datos están protegidos. Selección del sistema 3P = carga equilibrada trifásico (1 CT 3 o 4 hilos); 3P.n = carga desequilibrada trifásico con o sin neutro (3 o 4 hilos); 3P.I = carga equilibrada trifásica (1 CT 2 hilos); 3P.A = carga desequilibrada trifásico conexión ARON (3 hilos); 2P = bifásico (3 hilos); 1P = monofásico (2 hilos). Relación del transformador. CT 1 a 60000. VT 1.0 a 6000.0 Filtro. Escala operativa 0 a 100% de la escala visualizada. Coeficiente de filtrado 1 a 32. Acción de filtrado: medidas, alarmas, salida serie (variables fundamentales: V, A, W y sus derivadas). Visualización hasta 3 variables por página. Modo de funcionamiento de las alarmas: funciones “OR” o “AND” o “OR+AND” (ver tabla “AND/OR”). Hasta 16 alarmas libremente programables. Las alarmas pueden ser conectadas a cualquier variable de la tabla “ I ”. Puesta a cero. Por medio del teclado: todas las variables, incluidas variab. instant., min, max, dmd y variables de contadores. Max: A1, A2, A3, W1, W2, W3, Wdmd1-2-3, Wsys dmd, VAsys dmd; min: PF1, PF2, PF3; A1, A2, A3; V1, V2, V3; - dmd: A1, A2, A3, VA1, VA2, VA3, VAsys, W1, W2, W3, Wsys, A. Todos los contadores. Energías totales: kWh, kvarh; - Energías totales: kWh, kvarh; - contador horario. Max y min. [9] 17 19 21 24 23 5 6 7 8 9 1011 12 13 14 3 1 F1 L1 L2 L3 96 (back) [10] 17 15 24 23 L1 15 17 19 21 23 24 25 26 27 28 L2 L3 N F1= 315mA 17 15 24 23 [11] 17 15 24 23 [1] F1 F1 L1 L1 L2 L3 N N 17 19 15 24 23 26 25 [2] F1 L1 F L2 [13] N ITALIANO 11 12 13 14 17 19 21 24 23 28 27 [3] N F1 + L L1 L2 L3 RC VDC 17 19 21 24 23 28 27 [4] 2 1 VDC RC Out Out GND GND 12 11 13 14 L1 L2 L3 OC 2 17 19 21 15 24 23 26 25 28 27 [14] OC 1 [5] F1 VDC VDC L1 Out Out L2 L3 GND RC GND RC N 12 11 13 14 17 19 21 15 24 23 26 25 28 27 OC 1 L1 L2 17 19 21 24 23 26 25 28 27 [7] F1 L1 [b] [c] [1][2][3][4][5]- 1-phasig, 2 Leiter Anschluß 2-phasig, 3 Leiter Anschluß, 2 Strom-Wandler 3-phasig, 3 Leiter Anschluß, ARON 3-phasig, 3-Leiter Anschluß, ARON und 2 Sp.W.’s 3-phasig, 4-Leiter Anschluß, 4-Leiter, unsymmetrisch Last, 3 Strom-Wandler [6]- 3-phasig, 4-Leiter Anschluß, unsymmetrisch Last, 3 Strom-Wandler und 3 Spannungs-Wandler [7]- 3-phasig, 3-Leiter Anschluß, unsymmetrisch Last, 3 St.W. [8]- 3-phasig, 3-Leiter Anschluß, unsymmetrisch Last, 3 St.W. und 2 Sp.W. [9]- 3-phasig, 3-Leiter Anschluß, symmetrisch Last, 1 St.W. [10]- 3-phasig, 4-Leiter Anschluß, symmetrisch Last, 1 St.W. und 1 Sp.W. [11]- 3-phasig, 4-Leiter Anschluß, symmetrisch Last, 1 St.W. [12]- Stromversorgung Anschluß. Wert der SchmelzSicherung F: Stromversorgung L von 18 bis 60VAC/DC = 630mA. H Stromversorgung von 90 bis 260 VAC/DC = 125mA. [13]- Doppelter Relais-Ausgang [14]- Doppelter Open Kollektor Ausgang Der Wert des Last-Widerstands (Rc) muß so sein, daß der Strom des geschlossenen Kontakt kleiner als oder gleich 100mA ist. Die VDC Spannung muß kleiner als oder gleich 30VDC sein. VDC: äußere Stromversorgung Spannung OUT: positiver Ausgangskontakt (offener Kollektor Transistor). GND: Ausgangskontakt zu Erdung angeschlossen (offener Kollektor Transistor). [15]- RS485 Anschluß 4-Leiter [a]- letztes Gerät, [b]- Geräte 1...n, [c]- RS485/RS232 Umsetzer. [16]- RS485 Anschluß 2 Leiter [a]- letztes Gerät, [b]- Geräte 1...n, [c]- RS485/RS232 Umsetzer. ACHTUNG • Die Stromeingänge dürfen NUR über Stromwandler angeschlossen werden. Der direkten Anschluß ist nicht möglich. • Der Anschluß an Erde des Stromwandlers erzeugt einen Leckstrom von 0 bis 1.8 mA max abhängig von dem Wert der Eingangswiderstandes, vom Typ des Anschlußes und der Streckenspannung des Gerätes. • La connexion à la terre du transformateur de courant produit un courant de dispersion de 0 à 1,8mA max en fonction des valeurs d’impédance d’entrée, du type de connexion e de la tension de ligne mesurée par l’appareil. 05 GND 05 T 06 T 06 RS485 RS232 RX+ 07 RX+ 07 TX+ RX- 08 RX- 08 TX- TX+ 09 TX+ 09 RX+ TX- 10 TX- 10 RX- [9] 20 18 27 26 [10] 20 18 27 26 [11] F1 L2 L3 ATENCIÓN • Las entradas de intensidad pueden ser conectadas SOLO por medio de transformadores de intensidad. La conexión directa no es posible. • La conexión a tierra del transformador de intensidad genera una corriente de fuga de 0 a 1,8 mA max. que depende de los valores de impedancia de entrada, del tipo de conexión y de la tensión de línea medida por el instrumento. 20 22 24 27 26 DIN L1 18 20 22 24 26 27 28 29 30 31 L2 L3 N F1= 315mA 20 18 27 26 [1] F1 F1 L1 L1 L2 L3 N N 20 22 18 27 26 29 28 [2] [12] 04 02 F1 L1 F L2 [13] N 12 13 14 15 20 22 24 27 26 31 30 [3] F1 FRANÇAIS L1 [1]- Connexion 1-phase, 2 fils, 1 TC [2]- Connexion 2 phases, 3 fils, 2 TC [3]- Connexion 3 phases, 3 fils, ARON [4]- Connexion 3 phases, 3 fils, ARON et 2 TT [5]- Connexion 3 phases, 4 fils, charge non-équilibré, 3 TC [6]- Connexion 3 phases, 4 fils, charge non-équilibré, 3 TC et 3 TT [7]- Connexion 3 phases, 3 fils, charge non-équilibré, 3 TC [8]- Connexion 3 phases, 3 fils, charge non-équil., 3 TC et 2 TT [9]- Connexion 3 phases, 3 fils charge équilibré, 1 TC [10]- Connexion 3 phases 4 fils, charge équilibré, 1 TC et 1 TT [11]- Connexion 3 phases, 4 fils, charge équilibré, 1 TC [12]- Connexion d’alimentation. Valeur du fusible F: Alimentation L de 18 à 60 VCA/CC = 630mA. Alimentation H de 90 à 260 VCA/CC = 125mA. [13]- Double sortie relais [14]- Double sortie collecteur ouvert La valeur de la résistance de charge (Rc) doit permettre au courant à contact fermé d’être inférieure à 100mA; la tension VDC: doit être inférieure ou égale à 30 VCC. VDC: tension d’alimentation externe. OUT: contact positif de sortie (transistor à collecteur ouvert). GND: contact de sortie connecté à masse (transistor à collecteur ouvert). [15]- RS485 connexion 4 fils [a]- dernier appareil, [b]- Appareil1...n, [c]- convertisseur RS485/RS232. [16]- RS485 connexion 2 fils [a]- dernier appareil, [b]- Appareil 1...n, [c]- convertisseur RS485/RS232. L2 L3 [4] - L + 2 RC VDC 20 22 24 27 26 31 30 N 1 VDC RC Out Out GND GND 13 12 14 15 L1 L2 L3 20 22 24 18 27 26 29 28 31 30 OC 2 [5] F1 OC 1 [14] VDC VDC L1 Out L2 L3 GND Out RC GND RC N 13 12 14 15 20 22 24 18 27 26 29 28 31 30 [6] OC 2 ATTENTION • Les entrées de courant peuvent être connectés SEULEMENT au moyen de transformateurs de courant. La connexion directe n’est pas permise. OC 1 L1 L2 [a] L3 N PC 20 22 24 27 26 29 28 31 30 [7] 108,5mm F1 [15] L1 [b] [c] GND GND 06 GND 06 T 07 T 07 RS485 RS232 RX+ 08 RX+ 08 TX+ RX- 09 RX- 09 TX- TX+ 10 TX+ 10 RX+ TX- 11 TX- 11 RX- PC [15] L2 L3 [a] GND GND 05 06 T 06 RS485 RS232 RX+ 07 RX+ 07 TX+ RX- 08 RX- 08 TX- TX+ 09 TX+ 09 RX+ TX- 10 TX- 10 RX- PC [16] 96 61.4 91mm 15.4 107.5 mm mm ≤ 8mm 20 22 24 27 26 29 28 31 30 45 05 T 90 GND 90mm [8] [c] 96 17 19 21 24 23 26 25 28 27 [b] 96 [a] L2 L3 6 7 8 9 10 11 12 13 14 15 [1]- Conexión monofásica , 2 hilos, 1 CT [2]- Conexión bifásica, 3 hilos, 2 CT [3]- Conexión trifásica, 3 hilos, ARON [4]- Conexión trifásica, 3 hilos, ARON y 2 VT [5]- Conexión trifásica, 4 hilos, carga desequilibrada, 3 CT [6]- Conexión trifásica, 4 hilos, carga desequilibrada, 3 CT y 3 VT [7]- Conexión trifásica, 3 hilos, carga desequilibrada, 3 CT [8]- Conexión trifásica, 3 hilos, carga desequilibrada, 3 CT y 2 VT [9]- Conexión trifásica, 3 hilos, carga equilibrada, 1 CT [10]- Conexión trifásica, 4 hilos, carga equilibrada, 1 CT y 1 VT [11]- Conexión trifásica, 4 hilos, carga equilibrada, 1 CT [12]- Conexión de alimentación. Valor del fusible F: alimentación L de 18 a 60 VCA/CC = 630mA. Alimentación H de 90 a 260 VCA/CC = 125mA. [13]- Doble salida de relé. [14]- Doble salida de colector abierto. El valor de la resistencia de carga (Rc) debe permitir una corriente inferior a 100mA con el contacto cerrado, la tensión VCC debe ser menor o igual a 30VCC. VDC: tensión de alimentación externa. OUT: contacto de salida positivo (transistor a colector abierto). GND: contacto de salida conectado a tierra (transistor a colector abierto). [15]- RS485 conexión 4 hilos [a]- último instrumento, [b]- instrumento 1...n, [c]- convertidor RS485/RS232. [16]- RS485 conexión 2 hilos [a]- último instrumento, [b]- instrumento 1...n, [c]- convertidor RS485/RS232. L2 L3 L1 4 L1 GND GND 2 ESPAÑOL 45mm [a] L3 N [1]- collegamento mono fase, 2 fili, 1 TA [2]- collegamento bifase, 3 fili, 2 TA [3]- collegamento 3 fasi, 3 fili, ARON [4]- collegamento 3 fasi, 3 fili, ARON e 2 TV [5]- collegamento 3 fasi, 4 fili, carico sbilanciato, 3 TA [6]- collegamento 3 fasi, 4 fili, carico sbilanciato, 3 TA e 3 TV [7]- collegamento 3 fasi, 3 fili, carico sbilanciato, 3 TA [8]- collegamento 3 fasi, 3 fili, carico sbilanciato, 3 TA e 2 TV [9]- collegamento 3 fasi, 3 fili carico bilanciato, 1 TA [10]- collegamento 3 fasi, 4 fili, carico bilanciato, 1 TA e 1 TV [11]- collegamento 3 fasi, 4 fili, carico bilanciato, 1 TA [12]- collegamento di alimentazione. Valore del fusibile F: alimentazione L da 18 a 60 VCA/CC = 630mA. Alimentazione H da 90 a 260 VCA/CC = 125mA. [13]- Doppia uscita a relè [14]- Doppia uscita a collettore aperto Le resistenze di carico (Rc) devono essere dimensionate in modo che la corrente a contatto chiuso sia inferiore a 100mA; la tensione VDC deve essere minore o uguale a 30VCC. VDC: tensione di alimentazione (esterna). Out: contatto di uscita positivo (transistor a collettore aperto). GND: contatto di uscita collegato a massa (transistor a collettore aperto). [15]- RS485 connessione 4 fili [a]- ultimo strumento, [b]- strumento 1...n, [c]- convertitore RS485/RS232. [16]- RS485 connessione 2 fili [a]- ultimo strumento, [b]- strumento 1...n, [c]- convertitore RS485/RS232. ATTENZIONE • Gli ingressi di corrente possono essere collegati SOLO mediante trasformatori amperometrici. La connessione diretta non è permessa. • Il collegamento a terra del TA genera una corrente dispersa da 0 a 1,8mA max. dipendente dai valori di impedenza di ingresso, dal tipo di connessione e dalla tensione di linea misurata dallo strumento. [6] OC 2 DEUTSCH ATTENTION • The current inputs can be connected ONLY by means of current transformers. The direct connection is not allowed. • The connection to ground of the CT produces a leakage current from 0 to 1,8 mA max dependent on the values of the input impedance, on the type of connection and on the line voltage measured by the instrument . [12] 03 01 ENGLISH [1]- 1 phase 2-wire connection, 1 CT [2]- 2-phase, 3-wire connection, 2 CT’s [3]- 3-phase, 3-wire connection, ARON [4]- 3-phase, 3-wire connection, ARON and 2 VT’s [5]- 3-phase, 4-wire connection, unbalanced load, 3 CT’s [6]- 3-phase, 4-wire connection, unbalanced load, 3 CT’s and 3 VT [7]- 3-phase, 3-wire connection, unbalanced load, 3 CT [8]- 3-phase, 3-wire connection, unbalanced load, 3 CT and 2 VT [9]- 3-phase, 3-wire connection, balanced load, 1 CT [10]- 3-phase, 4-wire connection, balanced load, 1 CT and 1 VT [11]- 3-phase, 4-wire connection, balanced load, 1 CT [12]- Power supply connection. Fuse value F: power supply L from 18 to 60 VAC/DC = 630mA. H power supply from 90 to 260 VAC/DC = 125mA. [13]- Double relay output [14]- Double open collector output The value of the load resistances (Rc) must make the close-contact current be lower than 100mA; the VDC voltage must be lower than or equal to 30VDC. VDC: Power supply voltage (external). Out: positive output contact (open collector type transistor). GND: output contact connected to ground (open collector type transistor). [15]- RS485 connection 4 wires [a]- last instrument, [b]- instrument 1...n, [c]- RS485/RS232 transducer. [16]- RS485 connection 2 wires [a]- last instrument, [b]- instrument 1...n, [c]- RS485/RS232 transducer. 32.2 50 64.5 L1 L2 L3 [8] [b] [c] GND GND 06 GND 06 T 07 T 07 RS485 RS232 RX+ 08 RX+ 08 TX+ RX- 09 RX- 09 TX- TX+ 10 TX+ 10 RX+ TX- 11 TX- 11 RX- PC [16]