Installation manuel | Halsey Taylor 8221080883 Double Bubbler™ Lead Law Compliant 8 Gallon FS Stainless Steel Water Cooler E/PRF Guide d'installation
Ajouter à Mes manuels5 Des pages
▼
Scroll to page 2
of
5
XP8WQ*1D Owners Manual FLOOR MOUNT WATER COOLER PAGE 1 0000001091 (Rev. A - 02/16) XP8WQ*1D Note: Danger! Electric shock hazard. Disconnect power before servicing unit. Uses HFC-134A refrigerant 4, 7, 16 6 8 1, 2 17 22 SEE FIG. 3 31 26 25 21 23 32 15, 18 20 33 3 27 19 28 12 13, 14 29 30 FIG. 1 0000001091 (Rev. A - 02/16) PAGE 2 PAGE 3 FIG. 2 LEGEND/LEYENDA/LÉGENDE E = INSURE PROPER VENTILATION BY MAINTAINING 4" (102mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2 IN. (38mm) OUT WALL. ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 4" (102mm) (MÍN.) DE HOLGURA FROM WALL SHUT OFF BY OTHERS ENTRE LA REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3/8" DE DIÁM. EXT. A 1-1/2" ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 4" (102mm) (MIN.) ENTRE LES ÉVENTS DE L’ENCEINTE (38mm) FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCEROS. ET LE MUR. EMPLACEMENT RECOMMANDÉ D'ALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5 mm) D.E. F = WALL SCREW HOLES CONNECTANT UNE TUYAUTERIE DE 1-1/2 PO. (38mm) DEPUIS LE ROBINET D'ARRÊT FOURNI PAR D'AUTRES. AGUJEROS DE TORNILLOS DE PARED B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN TROUS DE VIS DU MUR UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1¼” DE DIÁMETRO. G = 2 X 4 BLOCKING EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE D’EAU. BLOQUEO DE 2 X 4 C = 1-1/4 TRAP NOT FURNISHED** BLOC 2 X 4 PURGADOR DE 1¼ NO PROPORCIONADO** SIPHON 1-1/4 NON FOURNI** D = ELECTRICAL OUTLET LOCATION UBICACIÓN DE LA TOMA DE ELECTRICIDAD EMPLACEMENT DE LA PRISE DE COURANT FINISHED FLOOR PISO ACABADO PLANCHER FINI XP8WQ*1D 0000001091 (Rev. A - 02/16) XP8WQ*1D PUSH BUTTON VALVE ADJUSTMENT 6 24 5 10 STREAM HEIGHT ADJUSTMENT SCREW 11 9 ADJUST THIS SCREW TO ELIMINATE VALVE LEVER "FREE PLAY" OR CONTINUOUS FLOW FROM BUBBLER FIG. 3 CONDENSER WATER VALVE ADJUSTMENT The condenser water valve is factory preset for a condenser water outlet temperature of 95° to 105° F. If actual temperature varies greatly from this, readjust water flow rate at the valve using the following procedures. 1. START UP COMPRESSOR This can be accomplished by depressing the cooler push button (See Fig. 1 - Item 2). Keep water running during the entire readjustment procedure. 2. ADJUSTMENT CONDENSER WATER VALVE Adjust valve by rotating adjustment stem. Rotating stem clockwise will increase water flow. Counterclockwise rotation will decrease water flow. Increasing water flow will result in a lower condenser outlet temperature, while decreasing water flow will result in a higher outlet temperature. Proper adjustment is attained when condenser outlet temperature is 95° to 105° F. FIG. 4 CORRECT STREAM HEIGHT FIG. 5 0000001091 (Rev. A - 02/16) PAGE 4 XP8WQ*1D PARTS LIST 115V ITEM PART NO. 1 2 3 4 5 6 7 8 9 10 11 12* 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 NS 101452331870 601451151550 28368C 102639931640 98531C 98533C 160270508640 28461C 26860C 26861C 26862C 36220C 35797C 35803C 600793851550 98683C 75589C 45340C 0000000240 45347C 45448C 56092C 1000002162 55880C 401536242830 401536342830 55996C 66798C 75561C 66202C 1000003361 1000001994 75494C 507442830 DESCRIPTION Stem Bushing Push Button Assy Brkt - Conduit Support Drain Plug Kit - Regulator/Holder/Nut Kit - Bubbler/Nipple/Gaskets Strainer Plate Basin Regulator Lever Pivot Bracket Regulator Retaining Bracket Compressor Service Pak Overload Relay Cold Control Assy Kit - Drain/Gasket/Adapter/Nut/Seal Gasket Electrical Box-Cold Control Kit - Heat Exchanger/Drier Electrical Box-Power Connection Tailpipe Assy Poly Tubing (Cut To Length) Kit - Union - 1/4 (3 Pack) Regulator Mounting Bracket Right Panel Left Panel Strainer Condenser Assy Elbow - 3/8 Drier - Note: for individual sale & also included in Item #19 Kit - Evaporator Replacement Kit - Tee - 1/4 (3 Pack) Check Valve Front Panel *INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY. NOTE: All correspondence pertaining to any of the above water coolers or orders for repair parts MUST include Model No. and Serial No. of cooler, name and part number of replacement part. 2222 CAMDEN COURT OAK BROOK, IL 60523 630.574.3500 PRINTED IN U.S.A. FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR VISIT OUR WEBSITE WWW.HALSEYTAYLOR.COM PAGE 5 0000001091 (Rev. A - 02/16)