PHOTON accessories | Инструкция по применению | Duevi PHOTON barriers Manuel du propriétaire
PDF
Скачать
Документ
Synchronisateur pour HUBs TC QUAND DEUX OU PLUSIEUR HUBS PEUVENT TRAVAILLER SANS PROBLEMES D’INTERFERENCE RECIPROQUES ? LORSQU’AUCUN RAYON DE N’IMPORTE LAQUELLE DES BARRES D’UN HUB DONNĖ HUB, SOIT ACCOUPLĖ DIRECTEMENT AVEC UNE CERTAINE AUTRE BARRE D’UN AUTRE HUB. À ANGLE DROIT AVEC UN DECALAGE HORIZONTAL DE 30° EN LIGNE , MAIS À UNE DISTANCE DE 600m OU À UN DECALAGE VERTICAL DE 30° QUAND EST-IL NECESSAIRE DE SYNCHRONISER DEUX OU PLUSIEURS HUBS ? LORSQU’AUCUN RAYON DE N’IMPORTE LAQUELLE DES BARRES D’UN HUB DONNĖ HUB, PEUT ETRE ACCOUPLĖ MEME INDIRECTEMENT AVEC N’IMPORTE QUELLE BARRE D’UN AUTRE HUB. FAUSSE ALARME ACCOUPLEMENT ACCIDENTENTEL INDIRECTE CAS OU IL NE SERAIT PAS NECESSAIRE D’UTILISER UN SYNCHRONISATEUR , MAIS QU’UN PROBABLE EVÈNEMENT EXTERNE (PAR-BRISE REFLETTENT D’UNE VOITURE GARÉE)POURRAIT CASER DES FAUSSES ALARMES IL EST ALORS IMPORTANT L’UTILISATION D’UN SYNCHRONISATEUR QUI IMMUNISE LE SYSTEME DES INTERFERENCES PRODUITS PAR UN AUTRE SYSTEME DE BARRIÈRE OPERABT DANS UNE ZONE LIMITROFE Synchronizing HUBs TC (rev 2) 3 EXEMPLES D’ INSTALLATIONS SYSTEME AVEC 8 ZONES EN LIGNE À DEUX HUB SYNCHRONISES 2X) ALARM 100 ms EXEMPLE D’UN SYSTEME AVEC 16 ZONES DONS 12 EN LIGNES SYNCHRONISÉES À 4X, PLUS 4 ZONES DECALÉES FONCTIONNANTES SANS SYNCHRONIME ALARM 200 ms ALARM 100 ms Synchronizing HUBs TC (rev 2) 4 EXEMPLE TYPIQUE D’INSTALLATION AVEC DEUX SECTIONS DE 8 ZONES EN LIGNE, LES ZONES SONT PERPENDICULAIRE ENTRE ELLES .LEURS BARRES RECIPROQUEMENT NE SE PERTUBE PAS EN THERME D’ONDES, IL EST ALORS SUFFICENT DE SYNCHRONISER LES SEULES ZONES EN LIGNE AVEC LE ZINCHRONIME 2X COMME ON PEUT LE CONSTATER , LES SORTIES SYNC 1 ET 2 SONT CONNECTÉES DEUX HUB EN PARALLELE, LE SYNCHRONISATEUR EST REDIMENSIONE POUR PILOTER JUSQU’À 5 HUB SUR LE MEME SINCHRONISME(UN TOTAL DE 40 HUB) ALARM 100 ms ALARM 100 ms SYNCHRONISATEUR MAX. CABLE LENGTH 33 FT. Synchronizing HUBs TC (rev 2) 6 SYNCHRONITEUR HUB TC ALIMENTATION: 9-16Vdc 200mA MAX (40 HUB TC connectés) SORTIES: N° 8 BRIDGED 0-5V / FAN OUT = 5 JUMPER X2: ACTIVE LES SORTIES SYNC1-2 LED BLINK 1-2 HUBS IN FULL SPEED – ALARME 100millisecondes JUMPER X4: ACTIVE. SORTIES SYNC1-2-3-4 LED BLINK 1-2-3-4 HUBS IN HALF SPEED – ALARM 200millisecondes JUMPER X8: ACTIVE LES SORTIES SYNC ET TOUS LES LED BLINK HUBS IN LOW SPEED – ALARME 400millisecondes RESET: BLOQUE TOUTES LES SORTIES SYNC CONNECTÉS SERVICES CONN.: ET LES HUBS CONNECTEUR DE PROGRAMMATION SIGNALISATION: N° 8 BLINK LED CONNECTIONS: LONGUEUR MAX DES CABLES SYNC 10m. 3.54 INTERAXE PERSSAGE FIXAGE 2.95 Synchronizing HUBs TC (rev 2) 3.26 2.10 7 Synchronizing HUBs TC (rev 2) 8 ">
Публичная ссылка обновлена
Публичная ссылка на ваш чат обновлена.