FHD7005*1E, THAD5*1E
Space-ette With FLEXI-GUARD
®
Installation/Care/Use Manual
USES HFC-134A REFRIGERANT
34 (SEE FIG. 5)
7
SEE FIG. 3
SEE FIG. 4
27
33 (SEE PAGE 3)
44
43
28
30
26
31, 32
13
18
19
16
17, 20
29
15
21
14
41, 42
22, 23, 24, 25
FIG. 1
PAGE 1
97420C (Rev. C - 3/01)
FHD7005*1E, THAD5*1E
FINISHED FLOOR
PISO ACABADO
PLANCHER FINI
FIG. 2
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2" (38mm) OUT FROM
WALL SHUT OFF BY OTHERS
SE RECOMIENDA UBICAR EL TUBO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3/8" DE DIAM. EXT. A 1-1/2" (38mm)
FUERA DE LA LLAVA DE PASO EN LA PARED COLOCADA POR TERCEROS.
EMPLACEMENT RECOMMANDÉ DALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5mm) D.E.
CONNECTANT UNE TUYAUTERIE DE 1-1/2 PO. (38mm) DEPUIS LE ROBINET D'ARRET FOURNI PAR D'AUTRES.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4 O.D. DRAIN
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1-1/4" DE DIÁMETRO.
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE DEAU.
C = 1-1/4 TRAP NOT FURNISHED
PURGADOR DE 1-1/4 NO PROPORCIONADO
SIPHON 1-1/4 NON FOURNI
D = INSURE PROPER VENTILATION BY MAINTAINING 4" (102mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 4" (102mm) (MÍN.) DE HOLGURA ENTRE LA REJILLA
DE VENTILACIÓN DEL MUEBLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 4" (102mm) (MIN.) ENTRE LES ÉVENTS DE LENCEINTE ET LE MUR.
E = POWER CORD 4 FEET (1219mm) LONG
CABLE ELÉCTRICO DE 4 PIE (1219mm), DE LARGO
CORDON DALIMENTATION 4' (1219mm)
97420C (Rev. C - 3/01)
PAGE 2
FHD7005*1E, THAD5*1E
SERVICING THE HOT CONTROL AND FUSE ASSEMBLY
1. A temperature sensing non-resetable fuse in the wire is located approximately 3" (76mm) from the thermostat.
The fuse is located under the retaining bracket (Item 3) in the groove on the heater element jacket (Item 4).
2. The thermostat must be used with a washer-spacer (Item 7) and be centered in the heater element jacket for
proper temperature control. Locate the heater element jacket about 3/4" (19mm) above the bottom of the tank.
3. The heater element jacket must be fastened VERY TIGHTLY to the tank (45+/-10 inch-lbs. of torque on the mounting
screw Item 9). Failure to TIGHTEN heater element jacket may cause rapid failure of the fuse assembly.
HOT TANK PARTS LIST
7
12
10
3
5
6
4
9
1
2
8
13
11
ITEM NO.
PART. NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
NS
22111C
22112C
22113C
30980C
31386C
31428C
50787C
70606C
70607C
70640C
70659C
70683C
70793C
22588C
Stream height is factory set at 35 PSI. If supply pressure varies
greatly from this, remove Items 1 & 2 and adjust screw on
Item 4. Clockwise adjustment will raise stream and counterclockwise adjustment will lower stream. For best adjustment,
stream should hit basin approximately 6-1/2" (165mm) from
bubbler.
DESCRIPTION
Heater Clamping Bracket
Heater Clamping Bracket (thrd)
Retaining Bracket
Heater Element & Jacket
Tank & Tube Assy
Hot Control Assy
Washer-Spacer
Drain Plug
Screw 1/4-20 x 3.00" HSHC
Screw #8-18 x 5/16" HHTC
Belleville Washer
1/4 Union
1/4 Elbow
Hot Tank Mounting Bracket
10
9
8
11
1
BASIN
2
3
12
4
NOTE:
WHEN INSTALLING REPLACEMENT
BUBBLER AND PEDESTAL, TIGHTEN NUT
(ITEM 12) ONLY TO HOLD PARTS SNUG IN
POSITION. DO NOT OVER TIGHTEN.
5
BASIN
6
FIG. 3
FIG. 4
WIRING DIAGRAM
35
This Drawing is merely for illustrating the
components of the electrical system.
36
38
37
40
39
FIG. 5
PAGE 3
97420C (Rev. C - 3/01)
FHD7005*1E, THAD5*1E
PARTS LIST 115V
ITEM NO.
PART NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22*
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
40089C
40048C
15005C
61313C
40169C
50986C
27843C
51349C
40322C
50934C
50168C
70012C
31513C
31495C
66303C
50189C
31490C
30664C
20282C
70018C
66201C
35787C
31034C
31797C
194243901550
55996C
56092C
70682C
66301C
66505C
21591C
30010C
31405C
40582C
40597C
92712C
51543C
40596C
70921C
33659000
50144C
70418C
55832C
21486C
21239C
21482C
20460C
NS
DESCRIPTION
Cover
Button
Regulator Retaining Nut
Regulator
Hex Nut
Regulator Holder
Basin & Drain Assy
Bubbler Assy
Orifice Assy
Housing Assy
Pedestal
Bubbler Locknut
Cold Control
Power Cord
Condenser
Fan Shroud
Fan Motor
Fan Blade
Fan Bracket
Fan Blade Nut
Drier
Compressor Serv. Pak PW4.5HK11
Overload/Relay Assy
Cover - Relay
Electrical Shield
Strainer
Poly Tubing 48" (Cut To Length)
Fitting - Tee 1/4
Heat Exchanger
Evaporator
Hot Tank Switch Bracket
Hot Tank Switch
Hot Tank Assy
Hot Valve Assy
Gooseneck
Hot Valve Kit
Handle
Shroud
Mounting Nut
Body Gasket
Grommet-Compressor
Washer-Compressor
Flow Regulator Assy
Cabinet-Sandalwood
Cabinet-Stainless Steel
Front Panel-Sandalwood
Front Panel-Stainless Steel
*REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL
ASSEMBLY. NOTE: All correspondence pertaining to ELKAY water
coolers or orders for repair parts MUST include Model No. and Serial No.
of cooler, name and part number of replacement part.
PRINTED IN U.S.A.
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
ELKAY MANUFACTURING COMPANY 2222 CAMDEN COURT OAK BROOK, IL 60523 630.574.8484
97420C (Rev. C - 3/01)
PAGE 4
">