Unilamp SKUNA - Bollard Wide Base Mode d'emploi
PDF
Download
Document
INSTALLATION MANUAL PRODUCT NAME : SKUNA - Bollard Wide Base SKUNA - Short Bollard Wide Base 1. 2. Ordering Code Input voltage No. IP66 7148/7149-I/K-3-524-XX 220-240V 50/60Hz On-off / DALI 7148/7149-I/K-3-867-XX 3. 7148/7149-I/K-3-868-XX 4. 7148/7149-I/K-3/5-523-XX 5. 7148/7149-I/K-3/5-897-XX 6. 7148/7149-I/K-3/5-898-XX 7. 7148/7149-I/K-3/5-567-XX 8. 7148/7149-I/K-3/5-569-XX 9. 7148/7149-I/K-3/5-571-XX 10. 11. 12. Constant Voltage ( Remote driver ) 24Vdc ( Output from SELV system only) ( ¡ÃÐáÊ俵ͧÁÒ¨Ò¡Ãкºáç´Ñ¹ä¿¿Ò µèíÒ¾ÔàÈÉ¢Ñé¹»ÅÍ´ÀÑÂà¾Õ§à·Ò¹Ñé¹) 7148/7149-I/K-7-580-XX 1-6,10-15 7-9 7148/7149-I/K-7-581-XX Light Emitting Diodes (LED) Light Emitting Diodes (LED) 7148/7149-I/K-7-582-XX 13. 7148/7149-I/K-7-577-XX 14. 7148/7149-I/K-7-578-XX 15. 7148/7149-I/K-7-579-XX 1 150 3 70 70 3.1 3.3 800 150 180 80 SKUNA - Bollard Wide Base 180 80 SKUNA - Short Bollard Wide Base Cable length 200 mm. ÊÒÂä¿ÂÒÇ 200 ÁÁ. 3.4 M8 x 1.25 3.5 200 2 30 500 3.2 Last Revised On : 19/09/2023 REV.01 60 Anchor bolt kit available separately ªØ´ÊÁͽ§¾×é¹ áÍÅâºÅ· ᡨíÒ˹Ò Ordering Code/ÃËÑÊÊÑè§«×éÍ :0500-0-9-000-00 80 Ø20 Ø9 160 180 1/5 FR-DM-17 REV.03 EFF 15/09/17 4.1 4.2 For CVDA System. For On-Off system. ÊíÒËÃѺÃкºà»´-»´ 4.1 ÊíÒËÃѺÃкºCVDA + L - DA1 N DA2 For DALI system. ÊíÒËÃѺÃкºDALI 4.2 Output ÍÍ¡ (L) Number on the cable/ËÁÒÂàÅ¢º¹ÊÒÂä¿ 1 : + A = 50-60 mm. A 2 : 3 : D1 NO 4 : D2 5: 2 Cable Size/¢¹Ò´ÊÒÂä¿ : 5x1.00 mm. Ø 7.1 -13 mm. - The connector has cutting blade inside. Don’t need to peel off an insulation sheath. - äÁµÍ§»ÅÍ¡©¹Ç¹ÊÒÂä¿ Input à¢Ò (L) L N Click DA1 DA2 5 Number on the cable/ËÁÒÂàÅ¢º¹ÊÒÂä¿ 1 : L 2 : N A = 50-60 mm. A 3 : D1 NO 4 : D2 5: 2 Cable Size/¢¹Ò´ÊÒÂä¿ : 5x1.00 mm. Ø 7.1 -13 mm. - The connector has cutting blade inside. Don’t need to peel off an insulation sheath. - äÁµÍ§»ÅÍ¡©¹Ç¹ÊÒÂä¿ Torque/áçºÔ´ : 11 Nm. Installation complete µÔ´µÑé§àÊÃç¨ÊÁºÙó For Constant Voltage LED 24V (Remote driver) Luminaires 1-n Warning Please ensure that the led lamp is connected to the driver correctly. Wrong polarity connection cause a damage to the led lamp and driver. â»Ã´ÃÐÇѧ¡ÒõÍÊÒÂä¿ÊÅѺ¢ÑéÇ +ºÇ¡ -ź ¨Ò¡ä´ÃàÇÍÃÁÒà¢Ò·ÕèËÅÍ´ LED ËÒ¡µÍÊÅѺ¢ÑéÇ ¨Ð·íÒãËä´ÃàÇÍÃáÅÐËÅÍ´ LED à¡Ô´¤ÇÒÁàÊÕÂËÒ Input/à¢Ò 220-240 V~ L AC N DC + + 1 - + 2 - + n - - Output/ÍÍ¡ 24 V ( Output from SELV system only) (¡ÃÐáÊ俵ͧÁÒ¨Ò¡Ãкºáç´Ñ¹ä¿¿Ò µèíÒ¾ÔàÈÉ¢Ñé¹»ÅÍ´ÀÑÂà¾Õ§à·Ò¹Ñé¹) Parallel wiring constant voltage Distance from luminaire to Driver ÃÐÂзҧ¨Ò¡µÑÇâ¤Á¶Ö§ ä´ÃàÇÍà Luminaire Wattage Maximum number of luminaires Conductor size / ¢¹Ò´ÊÒÂä¿ for parallel connection / ¨íҹǹâ¤Á㹡ÒõÍẺ¢¹Ò¹ 1.00 mm.2 1.50 mm.2 2.00 mm.2 Accessory available separately./ÍØ»¡Ã³àÊÃÔÁ¨íÒ˹ÒÂᡵҧËÒ¡ Ordering Code Product Name 0648-0-9-000-00 LED Constant Voltage Driver 24Vdc 72W. 14 W 1-3 luminaires 30 m 50 m 65 m 0445-0-9-000-00 LED Constant Voltage Driver 24Vdc 150W. 14 W 1-6 luminaires 15 m 25 m 35 m Last Revised On : 19/09/2023 REV.01 2/5 FR-DM-17 REV.03 EFF 15/09/17 Remark : ËÁÒÂà赯 Warning : ¢Í¤ÇÃÃÐÇѧ 1. The manufacturer will not be liable or held responsible for any incorrect installation, misuse or improper use and unauthorised modification to the fittings. Failure to comply with mentioned warning may cause serious damage or serious injury to persons, animals or objects. If any modification is required please consult your dealer for the details. ·Ò§¼Ù¼ÅÔµäÁÊÒÁÒöÃѺ¼Ô´ªÍºã¹¤ÇÒÁàÊÕÂËÒÂã´æ·Õèà¡Ô´¨Ò¡¡Òà µÔ´µÑé§äÁ¶Ù¡ÇÔ¸,Õ ãª§Ò¹¼Ô´»ÃÐàÀ·ËÃ×Í´Ñ´á»Å§µÑÇâ¤Áã¹·Ø¡¡Ã³Õ «Öè§ ÊÔè§¼Ô´»¡µÔàËÅÒ¹Õé ÍÒ¨·íÒãËà¡Ô´ÍѹµÃÒ¡Ѻ ¤¹ ÊÑµÇ ÊÔ觢ͧ ËÒ¡ÁÕ¢ÍʧÊÑÂËÃ×ÍÁÕ¤ÇÒÁµÍ§¡ÒûÃѺᵧµÑÇâ¤Á ãËàËÁÒÐÊÁ¡Ñº¡ÒÃ㪧ҹ ¡ÃسҵԴµÍµÑÇá·¹¨íÒ˹ÒÂËÃ×ͼټÅÔµ 1. Installation should be carried out by a qualified electrician in accordance with appropriate national wiring regulation. ¡ÒõԴµÑé§â¤Áä¿¿ÒáÅÐÍØ»¡Ã³ ¤ÇôíÒà¹Ô¹¡ÒÃâ´ÂªÒ§ä¿¿Ò ·ÕèÁÕ¤ÇÒÁÃÙáÅФÇÒÁªíÒ¹Ò­ 㹡ÒõԴµÑé§ÍØ»¡Ã³ä¿¿Ò â´Â੾ÒеÒÁÁÒµÃฐÒ¹¢Í§¡ÒÃä¿¿Ò 2. Disconnect the power before changing the lamp. »´ÊÇÔ·ªä¿·Ø¡¤ÃÑé§·Õèà»ÅÕè¹ËÅÍ´ä¿ 3. This is Class1 luminaire, the installation must be completed with earthing. â¤Áä¿Ãع¹Õé¶¡Ù ¨Ñ´äÇã¹»ÃÐàÀ·¢Í§¡Òûͧ¡Ñ¹ä¿¿ÒÃÑèÇ ÃдѺ 1 ·Õè¨ÐµÍ§µÍÊÒ´ԹµÒÁÁÒµÃฐÒ¹¤ÇÒÁ»ÅÍ´ÀÑ 2. Where damage has occured to the fittings, please make the replacement with standard parts before use. 㹡óշèÁÕ Õªé¹Ô Êǹ»ÃСͺã´à¡Ô´¤ÇÒÁàÊÕÂËÒÂ¡ÃØ³Òà»ÅÕ蹪Թé ÊǹãËÁ¡Í¹¡ÒÃ㪧ҹ·Ø¡¤ÃÑé§ à¾×èͤÇÒÁ»ÅÍ´ÀÑ 4. Do not exceed the maximum wattage. ËÒÁãªËÅÍ´ä¿·ÕèÁÕ¢¹Ò´Çѵµà¡Ô¹¡ÇÒ·ÕèÃÐºØ ËÃ×ÍãªËÅÍ´¼Ô´»ÃÐàÀ· 5. Don't touch LED while maintaining or cleaning. ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED ¢³ÐºíÒÃØ§ÃÑ¡ÉÒ ËÃ×Í·íÒ¤ÇÒÁÊÐÍÒ´ Cable Size/¢¹Ò´ÊÒÂä¿ : 3x1.00 mm.2 Ø8-10 mm. In case the supply cable is exposed to sunlight use UV resistant cable. ¡Ã³Õ·ÕèÁÕ¡ÒõԴµÑé§â¤Á俹͡ÍÒ¤Òà ËÃ×Íâ¤Áä¿·ÕèÁÕ¡ÒÃá¼ÃѧÊÕÂÙÇÕ ÊÒÂ俵ͧÊÒÁÒö»Í§¡Ñ¹ ËÃ×Í ÁÕ¡Òûͧ¡Ñ¹äÁã˶١ÃѧÊÕÂÙÇÕä´ NO 0.5 m Do not touch the LED because it may shorten the life time or the LED can be breaking down. ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED â´Âà´ç´¢Ò´ à¾ÃÒШзíÒãËËÅÍ´àÊ×èÍÁÊÀÒ¾ Minimum distance to lighted surface. ÃÐÂÐËÒ§¢Ñé¹µèíÒ ¨Ò¡Ë¹Òâ¤Á¶Ö§¾×é¹¼ÔÇ·Õè¶¡Ù ÊͧÊÇÒ§ The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 0.5m in not expected. µíÒá˹§·ÕèµÔ´µÑ駴ǧâ¤Á¤ÇÃÍÂÙ㹨ش·ÕèáʧäÁÊͧà¢Ò´Ç§µÒâ´ÂµÃ§à»¹àÇÅÒ¹Ò¹ ËÒ¡à¢Òã¡Åã¹ ÃÐÂйÍ¡ÇÒ 0.5 Á. Last Revised On : 19/09/2023 REV.01 3/5 FR-DM-17 REV.03 EFF 15/09/17 Any damaged safety glass cover must be replaced only with the original spare part. àÁ×èÍ¡ÃШ¡à¡Ô´¤ÇÒÁàÊÕÂËÒ à¾×èͤÇÒÁ»ÅÍ´ÀѤÇÃÊÑè§ÍÐäËÅá·¨Ò¡¼Ù¼ÅÔµà·Ò¹Ñé¹ NO NO LED Not using chemical compounds and aggressive agents such as , weed repellents fertilizers , acid solvent and contaminated irrigation water near the Luminaires. ËÒÁãªÊÒÃà¤ÁÕહ »ØÂ, ÂÒ¡íҨѴÈѵÃپת, »Ù¹¢ÒÇ, ÊÒÃÅÐÅÒ·Õè໹¡Ã´ áÅÐนําปนเปื อนสารเคมี ºÃÔàdz·ÕèµÔ´µÑé§â¤Áä¿ Clean the products regularly to maintain good light output and prolong surface quality . Only use solvent-free cleaning solutions on the products. ·íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ±à»¹»ÃШíÒà¾×èÍÃÑ¡ÉÒ¤ÇÒÁÊͧÊÇÒ§·Õè´ÕáÅÐÂ×´ÍÒÂØ¤Ø³ÀÒ¾¾×é¹¼ÔÇ ãª¹éíÒÂÒ·íÒ¤ÇÒÁÊÐÍÒ´·ÕèäÁÁÕáÍÅ¡ÍÎÍÅËÃ×͵ÑÇ·íÒÅÐÅÒ¡Ѻ¼ÅÔµÀѳ±à·Ò¹Ñé¹ NO Do not use a high pressure washer to clean the products. ËÒÁãªà¤Ã×èͧ©Õ´¹éíÒáç´Ñ¹Ê٧㹡Ò÷íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ± LED Our products are installed with electronic components with the protection against overvoltage according to IEC 61547. The customers have to install the additional overvoltage protection devices (against surge, transients, etc) in their electrical system to avoid the risk of damage. Failing to do so will end the product warranty. ¼ÅÔµÀѳ±¢Í§àÃÒÁÕ¡ÒõԴµÑé§ÍØ»¡Ã³ÍÔàÅç¡·Ã͹ԡÊÊíÒËÃѺ¡Òûͧ¡Ñ¹áç´Ñ¹ä¿à¡Ô¹µÒÁÁÒµÃฐÒ¹ IEC 61547 áÅÐÅÙ¡¤ÒµÍ§µÔ´µÑé§ÍØ»¡Ã³»Í §¡Ñ¹áç´Ñ¹ä¿à¡Ô¹à¾ÔèÁàµÔÁ (»Í§¡Ñ¹ä¿¡ÃЪҡ ,ä¿¿ÒÅѴǧ¨Ã ÏÅÏ) ã¹Ãкºä¿¿Ò´Ç à¾×èÍËÅÕ¡àÅÕ觤ÇÒÁàÊÕè§·Õè¨Ðà¡Ô´¤ÇÒÁ àÊÕÂËÒ ËÒ¡äÁ´íÒà¹Ô¹¡Òôѧ¡ÅÒÇ ¡ÒÃÃѺ»ÃСѹ¨ÐÊÔé¹Êشŧ LED To replace the LED module or the entrire luminaire.Please consult your sales representative. ËÒ¡µÍ§¡ÒÃà»ÅÕè¹ LED module ËÃ×Íâ¤Áä¿â»Ã´µÔ´µÍµÑÇá·¹¢Ò¢ͧ¤Ø³ LED 230V Last Revised On : 19/09/2023 REV.01 4/5 FR-DM-17 REV.03 EFF 15/09/17 LED LED To replace the LED module or the entrire luminaire.Please consult your sales representative. ËÒ¡µÍ§¡ÒÃà»ÅÕè¹ LED module ËÃ×Íâ¤Áä¿â»Ã´µÔ´µÍµÑÇá·¹¢Ò¢ͧ¤Ø³ Environmental protection: Waste electrical products should not be disposed of with household waste. please recycle where facilities exist.check with your local authority or retailer for recycling advice According to directive 2002/96/CE and directive 2012/19/EU Waste Electrical and Electronic Equipment (WEEE). ËÒÁ·Ôé§¼ÅÔµÀѳ±¹éÃÕ ÇÁ¡Ñº¢ÂÐ㹤ÃÑÇàÃ×͹ª¹Ô´Í×è¹æàÁ×èÍÊÔé¹ÊØ´ÍÒÂØ¡ÒÃ㪧ҹâ»Ã´á¡¼ÅÔµÀѳ±ÍÍ¡ ¨Ò¡¢Í§àÊÕ»ÃÐàÀ·Í×è¹æáÅÐÃÕä«à¤ÔÅÍÂÒ§àËÁÒÐÊÁà¾×èÍʧàÊÃÔÁ¡ÒùíÒ·ÃѾÂҡáÅѺÁÒ㪫íÒé «Ö觨ЪÇ »Í§¡Ñ¹ÍѹµÃÒµÍÊÔè§áÇ´ÅÍÁËÃ×ÍÊØ¢ÀÒ¾¢Í§Á¹ØÉ·Õèà¡Ô´¨Ò¡¡Ò÷Ôé§¢ÂÐâ´ÂäÁÁ¡Õ ÒäǺ¤ØÁ ÍÒ§ÍÔ§µÒÁÃÐàºÕº 2002/96/CE áÅÐÃÐàºÕº 2012/19/EU Waste Electrical and Electronic Equipment (WEEE). Replacing the LED module ÇÔ¸Õ¡ÒÃà»ÅÕè¹ LED module 1. Contact your sales representative for replacement LED modules. Make sure that the replacement module match the initially supplied module. Note the part number printed on the LED module. àµÃÕÂÁ LED module ã˵ç¡ÑºÃع·ÕèµÍ§¡ÒÃà»ÅÕè¹â´ÂµÃǨÊͺ·ÕèËÁÒÂàÅ¢·Õè¾ÔÁ¾º¹LED modules áÅÐ µÔ´µÍµÑÇá·¹¢ÒÂà¾×èÍÊÑè§«×éÍ LED modules ·ÕèµÍ§¡ÒÃà»ÅÕè¹ 2. The LED module can be replaced by qualified persons using standard tools. ¡ÒÃà»ÅÕè¹ LED module µÍ§·íÒâ´ÂªÒ§¼ÙªíÒ¹Ò­áÅÐãªà¤Ã×èͧÁ×Í·Õèä´ÁÒµÃฐÒ¹ 3. Disconnect power before opening the luminaire housing. µÑ´áËŧ¨ÒÂ信͹·Õè¨Ðà»´µÑÇâ¤Á 4. Replace the old LED module with the new LED module. Reapply thermal interface material as supplied with the new LED module. ¶Í´ LED module ·ÕèªíÒÃØ´ÍÍ¡ ¨Ò¡¹Ñ¹·íÒ¤ÇÒÁÊÐÍÒ´¨Ø´ÇÒ§ËÅÍ´ áÅǨ֧·íÒ¡ÒûÃСͺ LED module ãËÁ áÅеͧà»ÅÕè¹ á¼¹Thermal Pad ËÃ×Í Thermal Grease ´Ç·ء¤ÃÑé§ 5. Inspect gaskets and if required replace with new gaskets. Defective luminaire covers must be replaced. Inspect correct wiring of replaced LED module. µÃǨÊͺ»ÃÐà¡ç¹áÅЪÔé¹Êǹ¢Í§µÑÇâ¤Á ¶ÒªíÒÃØ´àÊÕÂËÒÂãË·íÒ¡ÒÃà»ÅÕè¹ãËÁ áÅеÃǨÊͺ¡ÒÃà¢ÒÊÒÂ俢ͧ LED module ·Õèà»ÅÕè¹ãËÁ¶Ù¡µÍ§ËÃ×ÍäÁ 6. Close the luminaire housing before reconnecting power. »´½Ò¤ÃͺÅçͤâ¤Áä¿ãËàÃÕºÃÍÂ¡Í¹à»´ä¿ Last Revised On : 09/06/2023 REV.07 5/5 FR-DM-17 REV.03 EFF 15/09/17 ">

Public link updated
The public link to your chat has been updated.