K Q

Robert K.

How is the time set on the IC2000P+?

On first power-up or after reset, select the language, set year, month, day, and time using - and +, and confirm each flashing value with ok. To change the time during use, press Menu, access the clock setting mode with +, change the date/time with - and +, and confirm with ok. The automatic summer/winter change can be set to SANS E/H (off) or AVEC E/H (on) with the zone selected.

K Q

Robert K.

How is the AUTO mode selected on the IC2000P+?

After initial configuration the device automatically enters AUTO mode. From another mode, select FIN in PROG to return to AUTO, press Menu to return to AUTO without saving the last change, or wait 2 minutes without pressing a key for automatic return to AUTO without saving.

K Q

Robert K.

How is the IC2000P+ reset?

Press simultaneously the -, menu, and ok keys. After reset, the device restarts the initial configuration: language selection, year/month/day/time setting, then hourly program selection and brightness threshold setting.

K Q

Robert K.

How can vacation mode be disabled on the IC2000P+?

Vacation mode normally ends automatically at the programmed absence end date and time. To exit manually, press Menu to return to AUTO without saving, or wait 2 minutes without key action for automatic return to AUTO. Verify that the vacation icon has disappeared and the device is in AUTO mode.