C P

Michael C.

How to remove manual mode from the motor without an LCD screen?
To remove manual mode without an LCD screen, reset the control parameters to factory settings by cutting off the power supply, pressing the (P) and (-) buttons on the board simultaneously, reactivating the power supply while holding down the buttons until the red LED (H6) flashes quickly, then releasing the buttons. After this initialization, the limit positions will be deleted, and all parameters will need to be reset to factory settings.
C P

Michael C.

What could be the problem if the control unit is working, but the motor isn't turning?
If the control unit is working but the motor isn't turning, check the power supply voltage and fuses. If using three-phase current, check that the rotating field is correct. Also, verify that the safety circuit is not interrupted. If the force control is too sensitive, it may also prevent the motor from turning.
C P

Michael C.

When the motor is powered by single-phase power, what should I check if the motor won't turn on?
If the motor is powered by single-phase power and it's not turning on, check the internal fuses (F2.1) of the control unit. Ensure that all motor connections are tight at both the control unit and the motor. If the installation requires a starting capacitor, confirm that it is in good condition and properly connected. Verify that the force is adequate; otherwise, the engine will not turn.