User questions

V E

Linda V.

Is it possible to install a 180 mm flue pipe for a heater with a 200 mm nozzle?

Yes, a 180 mm flue pipe is possible for the smoke duct provided that duct sizing complies with standard EN 13384.1 and DTU 24.1 regulations. Note that the device nozzle diameter remains 200 mm.

V E

Linda V.

Is it possible to install a 180 mm flue pipe for the heating system?

Yes, a 180 mm flue pipe is allowed for the smoke duct provided that sizing according to EN 13384.1 allows it and the installation complies with DTU 24.1. Note that the appliance nozzle diameter is 200 mm, so the 180 mm sizing applies to the flue pipe, not directly to the nozzle.