Patricia Q.

How to replace injectors and adjust the minimum gas flow for butane usage on the cooktop?

Replace existing injectors with butane-compatible ones (markings 85A, 66A, or 50). To adjust the minimum flow for butane (G30), remove the control knob and tighten the adjustment screw completely.

Q G

Patricia Q.

What is the procedure and specifications for replacing injectors for butane (G30) gas use on the appliance?

For butane (G30) gas use, first remove the grids (A) and burners (B). Using an appropriate socket wrench, unscrew the existing injector (C) and replace it with the butane (G30) compatible injector (D). Reassemble. For multi-crown burners, use the side wrench for injector (E). The required injector markings for Butane G30 (28-30 mbar) are: Rapid burner: 85 A; Semi-rapid burner: 66 A; Auxiliary burner: 50. The minimum gas flow adjustment screw must be fully tightened for LPG. After replacement, check for gas leaks with soapy water and verify flame stability from maximum to minimum position. This adaptation must be performed by a qualified technician.

Q G

Patricia Q.

How to adjust the minimum gas flow screw on the hob?

To adjust the minimum gas flow screw (small flame), remove the burner's control knob. To reduce flame height, tighten the screw (-); to increase, loosen it (+). For liquefied petroleum gas (Butane/Propane G30/G31), the screw must be fully tightened. Light the burner and quickly switch from maximum to minimum position to check flame stability; it should not extinguish. After adjustment, reseal the joint using sealing wax or equivalent material.

Q G

Patricia Q.

How to adapt the appliance for use with butane gas (G30)?

Replace the existing injectors with markers 85A (Rapid), 66A (Semi-rapid), or 50 (Auxiliary) using a socket wrench. For butane/LPG, the minimum flow adjustment screw (by-pass) must be fully tightened.