User questions

W K

Patricia W.

How to perform the electrical connections to the terminal block?

  1. Strip approximately 70 mm of the main power cable sheath and 10 mm of each individual conductor.
  2. Pass the cord through the cable clamp.
  3. Connect the conductors to the terminal block following the diagram printed on the cover.
  4. Ensure the yellow-green ground wire is connected to the terminal marked with the ground symbol.
  5. Secure the cord with the cable tie and replace the protection cover. Note: Use 3 X 2.5 mm² for 230 V ~ or 4 X 1.5 mm² for 230 V 3 ~ and 400 V 2N ~.
W K

Patricia W.

How to perform the electrical and terminal block connections?

Ensure the device is grounded and disconnected from power. Use appropriate wiring (e.g., 3 x 2.5 mm² for 230V). Strip 70mm of the main cable sheath and 10mm of the conductor insulation. Pass the cord through the cable clamp and connect the wires to the terminal block according to the diagram printed on the cover.

W K

Patricia W.

How to perform electrical connections and wiring to the terminal block?

Use conductors appropriate for the voltage (e.g., 3 X 2.5 mm² for 230V). Strip 70 mm of the main cable sheath and 10 mm of each individual conductor. Pass the cable through the strain relief and connect it to the terminal block according to the diagram on the cover. Connect the yellow-green grounding wire to the terminal marked with the earth symbol and secure the cable with the wire clamp.